USER MANUAL
W 9500Gen
Portable Generator
Gasoline: 9500 Running Watts | 12500 Peak Watts
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer
service at 855-944-3571.
2 | Westinghouse Outdoor Power Equipment, LLC
INTRODUCTION
INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and specications in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any specication or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
INTRODUCTION
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
SPECIFICATIONS....................................................................3
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 .................................................................
SAFETY INSTRUCTIONS 5 .......................................................
SAFETY LABELS AND DECALS 7 .............................................
COMPONENTS
GENERATOR COMPONENTS 8 ................................................
CONTROL PANEL COMPONENTS 9 .........................................
ASSEMBLY
CARTON CONTENTS 10 ...........................................................
INSTALL FEET AND WHEELS 10 ..............................................
INITIAL OIL FILL ....................................................................11
FUEL ...................................................................................... 11
CONNECT THE BATTERY ....................................................12
OPERATION
GENERATOR LOCATION 13 ......................................................
GROUNDING 13 .........................................................................
HIGH ALTITUDE OPERATION ..............................................14
REMOTE START ...................................................................14
BREAK-IN PERIOD 14 ...............................................................
BEFORE STARTING THE GENERATOR 15 ..............................
STARTING THE ENGINE ......................................................15
FREQUENCY OF USE 15 ..........................................................
AC CIRCUIT BREAKERS 15 ......................................................
POWER MANAGEMENT 16 .......................................................
EXTENSION CORDS 17 ............................................................
ST SWITCH 17 ............................................................................
TRANSPORTING 18 ...................................................................
MAINTENANCE
MAINTENANCE REMINDERS 19 ..............................................
MAINTENANCE SCHEDULE 19 ................................................
MAINTENANCE REPLACEMENT PARTS 19 ............................
AIR FILTER MAINTENANCE 19 .................................................
ENGINE OIL LEVEL CHECK 20 .................................................
ENGINE OIL CHANGE 20 ..........................................................
SPARK PLUG MAINTENANCE 21 .............................................
SPARK ARRESTOR SERVICE ..............................................21
BATTERY MAINTENANCE 21 ....................................................
BATTERY REPLACEMENT 21 ...................................................
STORAGE 22 ..............................................................................
VALVE CLEARANCE 23 .............................................................
TROUBLESHOOTING
TROUBLESHOOTING 24 ...........................................................
EXPLODED VIEWS AND PARTS LISTS
ENGINE EXPLODED VIEW 25 ...................................................
ENGINE PARTS LIST ............................................................26
ENGINE PARTS LIST CONTINUED 27 ......................................
GENERATOR EXPLODED VIEW 28 ..... ....................................
GENERATOR PARTS LIST ....................................................29
GENERATOR PARTS LIST CONTINUED 30 .............................
SCHEMATICS
SCHEMATICS 31 ........................................................................
ESPAÑOL .............................................................................32
FRANÇAIS ...........................................................................57
4 | Westinghouse Outdoor Power Equipment, LLC
SAFETY
SAFETY
SAFETY DEFINITIONS
The words DANGER, WARNING, CAUTION, and
NOTICE are used throughout this manual to highlight
important information. Make sure that the meanings of this
safety information is known to all who operate, perform
maintenance on, or are near the generator.
This safety alert symbol appears
with most safety statements. It
means attention, become alert, your
safety is involved! Please read and
abide by the message that follows
the safety alerts symbol.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage
to the generator, personal property, and/or the
environment, or cause the equipment to operate
improperly.
Note: Indicates a procedure, practice or condition
that should be followed for the generator to function
in the manner intended.
SAFETY SYMBOLS
Follow all safety information contained in this manual
and on the generator.
Symbol Description
Safety Alert Symbol
Electrocution Hazard
Asphyxiation Hazard
Burn Hazard. Do not touch hot surfaces.
Electrical Shock Hazard
Fire Hazard
Maintain Safe Distance
Lifting Hazard
Read Manufacturers Instructions
Do Not Operate in Wet Conditions
Westinghouse Outdoor Power Equipment, LLC | 5
SAFETY
SAFETY INSTRUCTIONS
NOTICE
Install battery-powered carbon monoxide detectors or
plug-in carbon monoxide detectors with battery back-up
in living areas.
Fire and electrocution hazard. Do not connect to
a building’s electrical system unless the generator
and transfer switch have been properly installed and
the electrical output has been veried by a qualied
electrician. The connection must isolate the generator
power from utility power and must comply with all
applicable laws and electrical codes.
Electrocution hazard. Never use the generator in a
location that is wet or damp. Never expose the generator
to rain, snow, water spray, or standing water while in
use. Protect the generator from all hazardous weather
conditions. Moisture or ice can cause a short circuit or
other malfunction in the electrical circuit.
6 | Westinghouse Outdoor Power Equipment, LLC
SAFETY
GENERAL SAFETY PRECAUTIONS
Never use the generator to power medical support
equipment.
Do not operate the generator when you are tired or
under the inuence of drugs, alcohol, or medication.
Do not use generator with electrical cords which are
worn, frayed, bare, or otherwise damaged.
All electrical tools and appliances operated from this
generator must be properly grounded by use of a third
wire or be double-insulated.
When this generator is used to supply a building wiring
system the generator must be installed by a qualied
electrician and connected to a transfer switch as a
separately derived system in accordance with NFPA 70,
National Electrical Code.
If you begin to feel sick, dizzy, or weak while using
the generator, move to fresh air IMMEDIATELY. See a
doctor, as you can have carbon monoxide poisoning.
Only use OUTSIDE and far away from windows, doors,
and vents as recommended by the US Department
of Health and Human Services Centers for Disease
Control and Prevention. Your specic home and/or wind
conditions may require additional distance.
While operating and storing, keep at least ve feet
of clearance on all sides of the generator, including
overhead. Allow the generator to cool a minimum of 30
minutes before storage. Heat created by the mufer and
exhaust gases could be hot enough to cause serious
burns and/or ignite combustible objects.
Do not touch the mufer or engine. They are very HOT
and will cause severe burns. Do not put body parts or
any ammable or combustible materials in the direct
path of the exhaust.
Always remove any tools or other service equipment
used during maintenance away from the generator
before operating.
Avoid skin contact with engine oil or gasoline. Wear
protective clothing and equipment. Wash all exposed
skin with soap and water.
FUEL SAFETY
Store fuel in a container approved for gasoline.
Do not smoke when lling the generator with gasoline.
Do not allow the generator’s gas tank to overow when
lling.
Shut down the engine and allow it to cool for two
minutes before adding gasoline or oil to the generator.
Never remove the fuel cap when the generator is
running. Shut off the engine and allow the unit to cool
at least two minutes. Remove the fuel cap slowly to
release pressure, keep fuel from escaping around the
cap, and to avoid the heat from the mufer igniting fuel
vapors. Tighten the fuel cap securely after refueling.
Wipe spilled fuel from the unit.
Never attempt to burn off spilled fuel.
Never overll the fuel tank. Leave room for fuel to
expand. Overlling the fuel tank can result in a sudden
overow of gasoline and result in spilled gasoline
coming in contact with HOT surfaces.
Spilled fuel can ignite. If fuel is spilled on the generator,
wipe up any spills immediately. Dispose of rag properly.
Allow area of spilled fuel to dry before operating the
generator.
Wear eye protection while refueling.
Never use gasoline as a cleaning agent.
Store any containers containing gasoline in a well-
ventilated area, away from any combustibles or source
of ignition.
GASOLINE AND GASOLINE VAPOR (GAS)
Fire and explosion hazard. Gasoline is highly explosive
and ammable and can cause severe burns or death.
In case of a gas re, do not attempt to extinguish
the ame if the fuel tank valve is in the ON position.
Introducing an extinguisher to a generator with an open
fuel valve could create an explosion hazard.
Gas has a distinctive odor, this will help detect potential
leaks quickly.
Gas vapors can cause a re if ignited.
Gasoline is a skin irritant and needs to be cleaned up
immediately if it comes in contact with the skin.
When starting the generator:
Make sure that the fuel cap, air lter, spark plug, fuel
lines, and exhaust system are properly in place.
If you spill any gasoline on the tank, allow it to fully
evaporate before operating.
When transporting or servicing the generator:
Disconnect the spark boot to prevent accidental starting.
When storing the generator:
Store away from sparks, open ames, pilot lights, heat,
and other sources of ignition.
Do not store gasoline near furnaces, water heaters,
or any other appliances that produce heat or have
automatic ignitions.
Westinghouse Outdoor Power Equipment, LLC | 7
SAFETY
SAFETY LABELS AND DECALS
CAU-
PRECAU-
ATTENTION
HOT SURFAC
SUPERFI CIES CALIE
AUX SURFACES C
AU-
CAU-
TENTIO N
HOT SURFAC ES
SUPERFICIES CALIENTES
AUX SURFACES CHAUDES
87 MINIMUM OCTANE
87 OCTANO MINIMUM
87 OCTANO MINIMO
E15
E85
DO NOT OVERFILL
USE FUEL STABILIZER
FOR STORAGE
UTILISEZ UN STABILISATEUR DE CARBURANT
POUR LE STOCKAGE
EL USO DEL ESTABILIZADOR DE COMBUSTIBLE
PARA EL ALMANCENAMEIENTO
25L
PELIGRO DE HUMOS TÓXICOS. Los motores en funcionamiento emiten
monóxido de carbono, un gas venenoso inodoro que puede causar
náuseas, desmayos o la muerte. No arranque el motor en interiores o en
un área cerrada, incluso si las ventanas y puertas están abiertas.
WARNING/ADVERTENCIA /AVERTISSEMENT
WARNING/ADVERTENCIA /AVERTISSEMENT
FOR ELECTRICAL EQUIPMENT ONLY
FOR USE IN A WEATHER PROTECTED
WELL VENTILATED AREA
NEUTRAL BONDED TO FRAME
SOLO PARA EQUIPOS ELÉCTRICOS
PARA USO EN UN ÁREA BIEN
VENTILADA PROTEGIDA POR EL CLIMA
NEUTRO VINCULADO AL MARCO
POUR MARIEL ÉLECTRIQUE SEULEMENT
POUR UTILISATION DANS UN ENDROIT BIEN
VENTILÉ ET PROTÉGÉE CONTRE LES
INTEMPÉRIES NEUTRE RELIÉ AU CHÂSSIS
CAUTION
PRECAUCIÓN
ATTENTION
HOT SURFACES
SUPERFICIES CALIENTES
AUX SURFACES CHAUDES
3
2
10
5
6
7
4
9
8
2
3
455
6 6
78
10
9
1Serial Number
Número de serie
Numéro de série
1
8 | Westinghouse Outdoor Power Equipment, LLC
COMPONENTS
COMPONENTS
GENERATOR COMPONENTS
Westinghouse Outdoor Power Equipment, LLC | 9
COMPONENTS
CONTROL PANEL COMPONENTS
5
4
2
1
3 86 7
13
12
11 10
14
9
1. Push-Button START/STOP: Push once to
automatically start the engine. Push again to stop
the engine.
2. Battery Switch: Turns battery ON and OFF. Must be
ON before electric or remote start.
3. Smart Switch Outlet: Connects the Westinghouse
ST Switch (sold separately) to the control panel.
4. USB Ports: Two-port 5V/2.1A USB outlet. Accepts
Type A USB plugs.
5. Main Circuit Breaker: The main circuit breaker controls
total output of all outlets to protect the generator from
overload or short circuit.
6. 120 Volt AC, 20 Amp Duplex GFCI NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
7. 120/240 Volt AC, 30 Amp NEMA 14-30R Twist-Lock
Receptacle: Receptacle can supply a maximum of
30 Amps.
8. 120/240 Volt AC, 50 Amp NEMA 14-50R
Receptacle: Receptacle can supply a maximum
of 50 Amps.
9. Ground Terminal: The ground terminal is used to
externally ground the generator.
10. 30 Amp AC Circuit Breakers: Circuit breakers
limits the current that can be delivered through each
leg of the NEMA 14-30R receptacle to 30 Amps.
11. 20 Amp AC Circuit Breakers: Circuit breakers
limits the current that can be delivered through the
NEMA 5-20R receptacles to 20 Amps.
12. Data Center: Toggle to show voltage, frequency,
total hour meter, and run/maintenance timer.
13. Battery Charging Port: Used to charge the battery
with the included battery charger.
14. Battery Indicator: Indicates that power is ON. Light
will remain illuminated while the unit is ON.
DATA CENTER
Run Time/Maintenance:
Disp s current run lay time.
Resets to zero when shut
down. Maintenance
reminder displayed
when required.
Frequency (Hz):
Displays power output
frequency in Hertz.
Voltage:
Displays current voltage
output.
Lifetime Hours:
Displays the lifetime run
hours.
Mode Button
METER V-F-T
Maintenance Codes:
P25: Change engine oil
P50: Clean air filter,
Change engine oil
P100: Change engine oil,
clean air filter, replace
fuel filter
Push the Mode button to cycle through
the data display modes.
10 | Westinghouse Outdoor Power Equipment, LLC
ASSEMBLY
ASSEMBLY
CARTON CONTENTS
Weight hazard. Always have assistance when lifting the
generator.
1. Carefully open the carton.
2. Remove and save the carton contents.
3. Remove and discard the packing tray.
4. Unfold the top of the plastic bag enclosing the generator.
5. Carefully cut the vertical corners of the carton to access
the generator.
6. Recycle or dispose of the packaging materials properly.
CARTON CONTENTS
User manual
Quick Start Guide/Maintenance Schedule
Remote start key fob (attached to recoil starter)
1.16 Quart (1.1 Liter) bottle of SAE 10W-30 Oil
Battery charger
Spark plug socket wrench
Oil Funnel
Assembly wrench
Wheel and mounting foot components
Item Quantity
Mounting foot 2
Flange bolt, M8 4
Wheel 2
Shaft pin 2
Washing machine 2
Cotter pin 2
If any parts are missing, contact our service team at
service@wpowereq.com or call 1-855-944-3571.
INSTALL FEET AND WHEELS
NOTICE
Assembling the generator will require lifting the unit on
one side. Install the mounting feet and wheel before
adding fuel or oil.
1. Place generator on a at surface.
2. Tip the generator on a piece of cardboard or other soft
material to protect the frame paint and prevent the
generator from sliding.
3. With the included wrench, install the mounting feet to
the frame as shown.
Mounting foot
Flange bolts
4. Install the wheels as shown.
Axle pin
Wheel
Cotter pin
Washer
Note: The wheels are only intended for hand transport.
The wheels are not suitable for towing the generator
either on or off-road.
Westinghouse Outdoor Power Equipment, LLC | 11
ASSEMBLY
INITIAL OIL FILL
NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT
OIL. Do not attempt to crank or start engine before it has
been properly serviced with recommended oil. Failure to
add engine oil before starting will result in serious engine
damage.
NOTICE
Use of 2-stroke/cycle oil or other unapproved oil types
can cause severe engine damage that is not covered
under warranty.
The included, recommended oil type for typical use is
10W-30 engine oil. If running the generator in extreme
temperatures, refer to the following chart.
1. On a level surface, remove the oil dipstick.
2. Using the supplied funnel and oil, add oil into oil ller
neck.
Note: As residual oil from the factory may remain in the
engine, add the oil incrementally near the end of the
bottle to prevent overlling the engine. See Engine
Oil Level Check in the Maintenance section.
3. Replace the oil dipstick and hand-tighten.
FUEL
Fire and explosion hazard. Never use a gasoline
container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
Fire and explosion hazard. Do not overll fuel tank. Fill
only to the red ll ring located in the in-tank fuel screen
lter. Overlling may cause fuel to spill onto engine
causing a re or explosion hazard.
Fire and explosion hazard. Never refuel the generator
while the engine is running. Always turn the engine off
and allow the generator to cool for two minutes before
refueling.
NOTICE
E85 E15
Do not use E15 or E85 fuel in this
product. Engine or equipment
damage caused by stale fuel or
the use of unapproved fuels (such
as E15 or E85 ethanol blends) is
not covered by warranty. Only use
unleaded gasoline containing up to
10% ethanol.
FUEL REQUIREMENTS
CLEAN, FRESH, unleaded gasoline, 87–93 octane.
Up to 10% ethanol (gasohol) is acceptable (where
available; non-ethanol fuel is recommended).
DO NOT use E85 or E15.
DO NOT use a gas oil mix.
DO NOT modify the engine to run on alternate fuels.
DO NOT fuel indoors.
DO NOT create a spark or ame while fueling.
USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable
life of fuel and helps prevent deposits from forming that
can clog the fuel system. Follow the manufacturer’s
instructions for use.
Always mix the correct amount of fuel stabilizer to gasoline
in an approved gasoline container before fueling the
generator. Run the generator for ve minutes to allow the
stabilizer to treat the entire fuel system.
12 | Westinghouse Outdoor Power Equipment, LLC
ASSEMBLY
FILLING THE FUEL TANK
1. Turn the generator OFF and allow to cool for a minimum
of two minutes before fueling.
2. Place the generator on level ground in a well ventilated
area.
3. Clean area around fuel cap and remove the cap slowly.
NOTICE
Only ll the tank from an approved gasoline container.
Make sure the gasoline container is internally clean and
in good condition to prevent fuel system contamination.
4. Slowly add the recommended fuel. Do not overll. Fill
only to the red maximum ll ring on the fuel screen lter
visible in the ller neck.
Maximum
Fuel Level
Screen
Filter
Fuel Cap
5. Install the fuel cap.
NOTICE
Fuel can damage paint and plastic. Use caution when
lling the fuel tank. Damage caused by spilled fuel is not
covered under warranty.
NOTICE
Clean the fuel screen lter of debris before and after
each fueling. Remove the fuel screen lter by slightly
compressing it while removing it from the fuel tank.
CONNECT THE BATTERY
A quick-connect battery plug is pre-installed on the battery.
Remove the cable tie securing the plugs then push rmly
to connect them.
Quick-Connect Plug
Note: The generator is equipped with a battery charging
feature. Once the engine is running, a small charge
will slowly recharge the battery.
Westinghouse Outdoor Power Equipment, LLC | 13
OPERATION
OPERATION
GENERATOR LOCATION
Read and understand all safety information before starting
the generator.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
DANGER
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and far
away from windows, doors,
and vents.
NEVER operate the generator inside any building, including
garages, basements, crawlspaces, sheds, enclosure, or
compartment, including the generator compartment of a
recreational vehicle.
Electrocution hazard. Never use the generator in a
location that is wet or damp. Never expose the generator
to rain, snow, water spray, or standing water while in
use. Protect the generator from all hazardous weather
conditions. Moisture or ice can cause a short circuit
or other malfunction in the electrical circuit. Using a
generator or electrical appliance in wet conditions, such
as rain or snow, or near a pool or sprinkler system, or
when your hands are wet, could result in electrocution
Fire hazard. Only operate the generator on a solid, level
surface. Operating the generator on a surface with loose
material such as sand or grass clippings can cause debris
to be ingested by the generator that could block cooling
vents or the air intake system. Allow the generator to
cool for 30 minutes before transport or storage.
The generator should be on a at, level surface at all times
(Even while not in operation). The generator must have
at least 5 ft. (1.5 m) of clearance from all combustible
material.
Do not operate the generator in the back of a SUV, camper,
trailer, truck bed (regular, at, or otherwise), under stairs,
next to walls or buildings, or in any other location that will
not allow for adequate cooling of the generator and/or the
mufer. DO NOT contain generators during operation.
Asphyxiation hazard. Place the generator in a well-
ventilated area. DO NOT place the generator near vents
or intakes where exhaust fumes could be drawn into
occupied or conned spaces. Carefully consider wind
and air currents when positioning the generator.
GROUNDING
Shock hazard. Failure to properly ground the generator
can result in electric shock.
NOTICE
Only use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
The generator neutral is bonded to the frame. There is a
permanent conductor between the generator (stator wire)
and the frame. If this generator will be used only with cord
and plug equipment connected to the receptacles mounted
on the generator, National Electric Code does not require
that the unit be grounded. However, other methods of
using the generator may require grounding to reduce the
risk of shock or electrocution.
Before using the ground terminal, consult a qualied
electrician, electrical inspector, or local agency having
jurisdiction for local codes or ordinances that apply to the
intended use of the generator.
DISCONNECTING THE BONDED NEUTRAL
Removing the bonded neutral disables the GFCI protection
from the 5-20R receptacles. The bonded neutral should
only be removed under specic circumstances. Consult a
qualied electrician to determine if your situation requires
disconnecting the bonded neutral.
1. Remove the alternator cover.
2. Remove the bonded jumper wire and reinstall the nut.
Neutral ground wire
Bonded jumper wire
14 | Westinghouse Outdoor Power Equipment, LLC
OPERATION
3. Remove the nut securing the neutral ground wire and
attach the bonded jumper wire. Reinstall the nut.
Bonded jumper wire
Neutral ground wire
4. Reinstall the alternator cover.
IMPORTANT: Apply a new “NEUTRAL UNBONDED”
Label over the “NEUTRAL BONDED TO
FRAME” label on the front of the control
panel.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at
altitudes over 2,000 ft. (762 m). Operation without this
adjustment will cause decreased performance, increased
fuel consumption, and increased emissions.
NOTICE
Do not operate the generator at altitudes below 2,000 ft.
(762 m) with the high altitude kit installed. Engine damage
may occur.
High Altitude Carburetor Kit Part# 518076-1
REMOTE START
Verify that the area around the generator is clear before
remote starting the generator.
The remote start key fob included with the generator should
be attached to the recoil handle or control panel. If your
unit was shipped without a key fob, contact Westinghouse
customer service.
The generator can be started remotely from up to 99 feet
(30 meter) using the remote start key fob.
Note: As the batteries in the remote start key fob drain,
operational distance will decrease.
PAIRING THE REMOTE START
Remote replacement batteries: (2) CR2016
If the remote start key fob is replaced or needs re-paired to
the generator, follow this procedure.
1. Turn the generator battery switch to the ON position.
The power indicator light will illuminate.
Battery switch
Push button START/STOP
Power indicator
2. Push and hold the red Pairing button on the side of the
control panel until the START/STOP button illuminates.
Pairing button
3. Push and hold the STOP button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
Key Fob
Activation Light
START Button
STOP Button
START
STOP
4. Push and hold the START button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
5. Push the Pairing button on the side of the control panel
until the START/STOP button illumination turns OFF.
Release the button.
6. Turn the generator battery switch to the OFF position.
The remote is now paired.
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running
watts (4750 watts) during the rst ve hours of operation.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
Westinghouse Outdoor Power Equipment, LLC | 15
OPERATION
BEFORE STARTING THE GENERATOR
Verify that:
The generator is placed in an safe, appropriate location.
The generator is on a dry, at, and level surface.
The engine is lled with oil.
All loads are disconnected.
Fire and explosion hazard. DO NOT move or tip the
generator during operation.
STARTING THE ENGINE
1. Verify that fuel is in the gas tank.
2. Turn the fuel selector switch on the control panel to
gasoline operation.
3. Turn the fuel tank valve to the ON position.
ON
OFF
4. Push the battery switch to the ON position.
5. Choose the starting method:
a. Remote Start: Push and hold the START button on
the remote start key fob for one second.
b. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.
c. Recoil Start: Manually close the choke if the engine
is cold. Firmly grasp and pull the recoil handle slowly
until you feel increased resistance, then pull rapidly.
d. Cold start: Close the choke by moving it right
toward the front handle of the generator.
STOPPING THE ENGINE
1. Turn off and unplug all connected electrical loads.
IMPORTANT: Never start or stop the generator with
electrical devices connected.
2. Let the generator run with no load for several minutes to
stabilize internal temperatures of the engine.
3. Push and hold the START/STOP button for one second
or push STOP on the remote start key fob for one
second.
Note: Alternately, if the generator is used infrequently, turn
the fuel tank valve to the OFF position to limit the
residual fuel remaining in the carburetor oat bowl.
The engine will stop when fuel in the carburetor and
fuel line is exhausted.
4. Push the battery switch to the OFF position.
FREQUENCY OF USE
If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to
the Battery Maintenance and Storage sections of this
manual for information regarding battery charging and fuel
deterioration.
AC CIRCUIT BREAKERS
The circuit breakers will automatically switch OFF if
there is a short circuit or a signicant overload of the
generator at each receptacle. The main circuit breaker
will automatically switch OFF if the combined load of the
receptacles exceeds 40 Amps.
If an AC circuit breaker switches OFF automatically,
check that the appliance is working correctly and it does
not exceed the rated load capacity of the circuit before
resetting the AC circuit breaker ON.
Tripped
Operating
Push to Reset
ON
OFF
Receptacle Circuit Breakers Main Circuit Breaker
16 | Westinghouse Outdoor Power Equipment, LLC
OPERATION
GENERATOR CAPACITY
NOTICE
Do not overload the generator’s capacity. Exceeding the
generator’s wattage/amperage capacity can damage
the generator and/or electrical devices connected to it.
Make sure the generator can supply enough continuous
(running) and surge (starting) watts for the items you will
power at the same time.
The total power requirements (Volts x Amps = Watts) of all
appliances connected must be considered. Appliance and
power tool manufacturers usually list rating information
near the model or serial number.
To determine power requirements:
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This
is the amount of power the generator must produce
to keep the items running. See the wattage reference
chart on the next page.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Tool or Appliance Running
Watts*
Starting
Watts*
RV Air Conditioner (11,000 BTU) 1010 1600
TV (Tube Type) 300 0
RV Refrigerator 180 600
Radio 200 0
Light (75 Watts) 300 0
Coffee Maker 600 0
2590 Total
Running
Watts*
1600
Highest
Starting
Watts*
Total Running Watts 2590
Highest Starting Watts + 1600
Total Starting Watts Needed 4190
*Wattages listed are approximate. Verify actual wattage.
POWER MANAGEMENT
To prolong the life of the generator and attached devices,
use care when adding electrical loads to the generator.
There should be nothing connected to the generator
outlets before starting the engine. The correct and safe
way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the rst load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Wattage Reference
Tool or Appliance
Estimated
Running
Watts*
Estimated
Starting
Watts*
Incandescent Lights
(4 Quantity x 75 Watts) 300 0
TV (Tube Type) 300 0
Sump Pump (1/3 hp) 800 1300
Refrigerator or Freezer 700 2200
Well Pump (1/3 hp) 1000 2000
Furnace (1/2 hp) 800 2350
Radio 200 0
Drill (3/8”, 4 amps) 440 600
Circular Saw
(Heavy Duty, 7-1/4”) 1400 2300
Miter Saw (10”) 1800 1800
Table Saw (10”) 2000 2000
*Wattages listed are approximate. Verify actual wattage.
Westinghouse Outdoor Power Equipment, LLC | 17
OPERATION
EXTENSION CORDS
Asphyxiation hazard. Extension cords running directly
into the home increase the risk of carbon monoxide
poisoning through any openings. If an extension cord
running directly into your home is used to power indoor
items, there is a risk of carbon monoxide poisoning to
people inside the home. Always use battery-powered
carbon monoxide detector (s) that meet current UL 2034
safety standards when running the generator. Regularly
check the detector (s) battery.
Asphyxiation hazard. When operating the generator with
extension cords, make sure the generator is located in
an open, outdoor area, far away from occupied spaces
with exhaust pointed away.
Fire and electrocution hazard. Never use worn or
damaged extension cords. Damaged or overloaded
extension cords could overheat, arc, and burn resulting
in death or serious injury.
Before connecting an AC appliance or power cord to the
generator:
Use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
Make sure the tool or appliance is in good working
order. Faulty appliances or power cords can create a
potential for electric shock.
Make sure the electrical rating of the tool or appliance
does not exceed the rated power of the generator or the
receptacle being used.
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for
outdoor use that are rated for the electrical load.
ST SWITCH
The unit is compatible with the ST Switch, purchased
separately. When utility power is on it will provide power (up
to 120V @ 20A) to the appliances plugged into the 5-20R
receptacle on the ST Switch. When utility power is lost the
ST Switch automatically transfers input power from utility
to generator power. When utility power is restored, the
ST Switch transfers input power back to utility. Visit www.
westinghouseoutdoorpower.com for more information.