Whirlpool AKT 352 Manual


Læs nedenfor 📖 manual på dansk for Whirlpool AKT 352 (6 sider) i kategorien Kogeplade. Denne guide var nyttig for 19 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
AKT 352 PRODUCT DESCRIPTION SHEET
GB
5019 319 01501 To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
CZ SK
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anticlockwise to the maximum flame setting .
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over,
etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For optimum burner performance, observe the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1
2
5
3
4
1. Removable grid(s)
2. Semi-rapid burner
3. Rapid burner
4. Semi-rapid burner control knob
5. Rapid burner control knob
SYMBOLS
Tap closed
Max. flame
Min. flame
Burner Pot Ø
Rapid from 24 to 26 cm
Semi-rapid from 16 to 22 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In the event a hood is fitted above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE CATEGORY II2H3B/P
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas used Type of
burner
Injector
marking
Nominal heating
capacity
kW
Nominal
consumption
Reduced
heating capacity
kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
rapid
semi-rapid
128
95
3.00
1.65
286 l/h
157 l/h
0.60
0.35 17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
rapid
semi-rapid
87
67
3.00
1.65
218 g/h
120 g/h
0.60
0.35 20 30 35
Type of gas used Model configuration Nominal heating capacity
kW
Total nominal
consumption
Air necessary (m3) for the
combustion of 1 m3 of gas
G20 20 mbar 2 burners 4.65 443 l/h 9.52
G30-G31 30 mbar 2 burners 4.65 338 g/h 30.94


Produkt Specifikationer

Mærke: Whirlpool
Kategori: Kogeplade
Model: AKT 352

Har du brug for hjælp?

Hvis du har brug for hjælp til Whirlpool AKT 352 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Kogeplade Whirlpool Manualer

Kogeplade Manualer

Nyeste Kogeplade Manualer

AEG

AEG HG654421 Manual

15 Januar 2025
AEG

AEG HDM55108XB Manual

15 Januar 2025
Etna

Etna tek 161 Manual

15 Januar 2025
Siemens

Siemens et511502 Manual

15 Januar 2025
BEKO

BEKO hii 64400 t Manual

15 Januar 2025
AEG

AEG HKM95513FB Manual

15 Januar 2025
Zanussi

Zanussi ZGH66424XS Manual

15 Januar 2025
Etna

Etna t 1025 zta Manual

15 Januar 2025