Barska AX11644 Manual

Barska Vault AX11644

Læs nedenfor 📖 manual på dansk for Barska AX11644 (2 sider) i kategorien Vault. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Users Manual for
Biometric/Key Pad Safe
WARNING
- Safe can be opened by either Fingerprint, PIN code,
and/or Emergency Keys.
- If user resets the safe to Factory Default mode: ANY
fingerprint and Factory Default PIN code can open
the safe.
- Register both Fingerprint and PIN code to disable
Factory Default mode.
- Register at least two different fingerprints and test a few
times before closing the safe door.
- Test with a non-registered fingerprint. If the safe opens,
the safe is still in Factory Default mode.
- Avoid leaving safe door open and unattended; it will allow
unauthorized individuals to add their fingerprints and/or
reprogram the safe, gaining full access to the safe and
the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the safe,
test registered fingerprints every 6 months.
Read all instructions before using this safe.
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
AB
C
I
D
F
G
E
H
F. Enter Button
G. Key Pad
H. Knob
I. Logo Plate and
Emergency Key Access
* Actual model may vary
GETTING STARTED
1. Remove Emergency Keys from accessory package
- To expose the Emergency Key Access, remove Logo Plate
(I) screws with provided tool
- Insert Emergency Key into key access, push and turn
counter-clockwise
- Turn the Knob (H) clockwise to open
Note: Store Emergency Keys in a secure place, NOT inside of
the safe
2. Continue with INSTALL BATTERIES
INSTALL BATTERIES
1. With safe door open, remove Battery Compartment (B) cover
- Insert 4 AA batteries and restore battery cover
- Continue with FINGERPRINT REGISTRATION
FINGERPRINT REGISTRATION
IMPORTANT: The safe is in either Factory Default mode or
Pre-registered mode, test safe to determine factory settings
below
Factory Default mode: Safe can be opened with ANY
fingerprint(s)
Pre-registered mode: Safe can NOT open with any fingerprint(s)
During registration the door must remain open and Bolts (C)
must be in the retracted position. Otherwise, the fingerprint will
not be saved
To retract bolts:
- Insert Emergency Key into key access, push and turn
counter-clockwise
- Turn the Knob (H) clockwise to retract bolts
1. Press and release Initialization Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- Two beeps will be heard recognizing the fingerprint; followed
by one long beep
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when two short beeps are heard,
followed by one long beep
Unsuccessful Registration
Registration failed if two short beeps are heard, followed by
three short beeps
3. To register another fingerprint, repeat steps 1 - 2
4. Continue with TEST A (NON) REGISTERED FINGERPRINT
Fingerprint Memory Full
If the Indicator Lights (E) flash and beep twice followed by a few
green flashes, it indicates the memory is full. Refer to DELETE
STORED FINGERPRINTS AND PIN CODE / RESET TO
FACTORY DEFAULT MODE for more options
TEST A (NON) REGISTERED FINGERPRINT
1. Test multiple Non-Registered fingerprints
- Close safe door and lock by turning the Knob (H) counter-
clockwise
- To begin the testing process, press and release Enter
Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Door should NOT open; three short beeps will be heard
- If the door opens with a non-registered fingerprint,
registration was unsuccessful; the safe remains in Factory
Default mode
IMPORTANT: If registration was unsuccessful repeat steps
under FINGERPRINT REGISTRATION, and test non-registered
fingerprint
2. Test Registered fingerprint
- Close safe door and lock by turning the Knob (H) counter-
clockwise
- To begin the testing process, press and release Enter
Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Door should OPEN, one long beep will be heard, turn the
Knob (H) clockwise to open the safe
- Fingerprint registration was successful
3. Continue with PIN CODE REGISTRATION
PIN CODE REGISTRATION
IMPORTANT: Safe only retains one PIN code; Factory Default
PIN code is 1234
1. Press and HOLD number “1” key until the green Indicator
Light (E) turns on, release button
- Enter Factory Default PIN code 1234, press Enter Button
(F), one long beep will be heard
- Enter new PIN code (four to eight digits), press Enter Button
(F), two short beeps will be heard
- Re-enter new PIN code, press Enter Button (F), one long
beep will be heard
- Registration is complete
2. If you hear three short beeps with red/green Indicator Lights
(E) flashing, it indicates the new PIN code registration was
unsuccessful, repeat step 1
3. Continue with TEST A (NON) REGISTERED PIN CODE
See reverse side for more information
10/12
BC256
U
n
l
o
c
k
L
o
c
k


Produkt Specifikationer

Mærke: Barska
Kategori: Vault
Model: AX11644

Har du brug for hjælp?

Hvis du har brug for hjælp til Barska AX11644 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vault Barska Manualer

Barska

Barska AX11820 Manual

25 August 2024
Barska

Barska AX13368 Manual

25 August 2024
Barska

Barska CB11794 Manual

25 August 2024
Barska

Barska AX11646 Manual

25 August 2024
Barska

Barska AX11970 Manual

25 August 2024
Barska

Barska AX11650 Manual

25 August 2024
Barska

Barska CB11784 Manual

25 August 2024
Barska

Barska AX11780 Manual

25 August 2024
Barska

Barska AX11838 Manual

25 August 2024
Barska

Barska AX12842 Manual

25 August 2024

Vault Manualer

Nyeste Vault Manualer

Stamony

Stamony ST-KS-100N Manual

15 Oktober 2024
Stamony

Stamony ST-KB-200 Manual

15 Oktober 2024
Phoenix

Phoenix FS1512 Manual

14 Oktober 2024
Phoenix

Phoenix CB0102K Manual

14 Oktober 2024
Phoenix

Phoenix FS1911 Manual

14 Oktober 2024
Phoenix

Phoenix GS8017 Manual

14 Oktober 2024
Phoenix

Phoenix HS3554 Manual

5 Oktober 2024
Phoenix

Phoenix HS6076 Manual

5 Oktober 2024