Getting Started
1. Remove safe from packaging and remove Manual and
all accessories that came with the safe.
2. Insert emergency key into key access, and turn
clockwise to unlock and open the safe.
3. Unscrew battery compartment and insert 4 AA
batteries. (Bolts are extended). Do not mix old and
new batteries.
4. Place any fingerprint on scanner. Few beeps will be
heard and red flashes will be seen, then bolts will
retract, the safe will open.
Note: If safe opens with few beeps and red flashes, this
means safe is in factory default mode: ANY Fingerprint
can open the safe.
Fingerprint Registration
1. With safe open and bolts retracted, press and release
initialization button located inside the safe and place
desired finger on fingerprint scanner.
Successful Registration
2 beeps will be heard and 2 green flashes will be seen.
Unsuccessful Registration
2 quick beeps will be heard along with red flash.
Test Registered Fingerprint
1. With safe door open, press “0” on keypad to extend
the bolts, the safe is locked.
2. Press “0” to wake up safe and place Registered
Fingerprint on the scanner. If safe bolts retract and 2
beeps and green flash is seen, it means the
registration was successful. If safe opens with several
beeps and red flash is seen then registration was
unsuccessful. Follow steps under Fingerprint
Registration to register safe.
Pin Code Registration
1. Enter Current Pin Code (Default Pin Code:
“12312312312”) then immediately press “3” on keypad,
both red and green light should be seen.
2. Enter new desired Pin Code 4 – 11 digits. If less than
11 digits, press initialization button on the back of the
safe to finish. 1 long beep will be heard and green light
will be seen.
Note: Pin Code CANNOT start with “0”
See reverse side for more information 8/15
BC443
WARNING
Test Registered Pin Code
1. With safe door open, press “0” on keypad to extend
the bolts, the safe is locked.
2 Enter Registered Pin Code. If there are beeps and
green light flashes, bolts retract then registration was
successful. If there are two short beeps and red light
flashes, bolts do NOT retract then registration was
unsuccessful. Follow steps under Pin Code
Registration to register desired Pin Code.
Close / Open Safe Door
Open Safe Door with Fingerprint
Press “0” on keypad to wake up the safe and place
Registered Finger on the scanner. Safe should open.
Open Safe Door with Pin Code
Enter Registered Pin Code and safe should open.
Closing Safe Door
Please push door against the body of the safe and press
“0” on keypad. Bolts should extend and Safe door is now
locked.
Silent Mode
Sound Off
Press and hold initialization button until 1 beep is
heard along with green flash. Sound is now disabled.
Note: Door Open Alarm will not beep when safe is in
silent mode, but green light will flash once every
4 seconds.
Sound On
Press and hold initialization button until 1 beep is
heard along with green flash.
Door Open Alarm
Safe will start beeping 1 min after safe door has been
opened. Please close safe door or turn safe to silent
mode to turn off alarm.
* Actual model may vary
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
User’s Manual for Biometric Keypad Safe
Read all instructions before using this safe
- Safe can be opened by either Fingerprint, PIN code,
and/or Emergency Keys.
- If user resets the safe to Factory Default mode: ANY
fingerprint and Factory Default PIN code can open
the safe.
- If safe is in factory default mode Red flash will be seen
along with several beeps when accessing the safe.
- Register BOTH Fingerprint and PIN code to disable
factory default mode.
- Register at least two different fingerprints and test a few
times before closing the safe door.
- Test with a non-registered fingerprint. If the safe opens,
the safe is still in Factory Default mode.
- Avoid leaving safe door open and unattended; it will allow
unauthorized individuals to add their fingerprints and/or
reprogram the safe, gaining full access to the safe and
the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the safe,
test registered fingerprints every 6 months.
E. Indicator Lights
F. Emergency Key Access
G. Key Pad
G
A
B
D
E
C
F
Produkt Specifikationer
Mærke: | Barska |
Kategori: | Vault |
Model: | AX12842 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Barska AX12842 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Vault Barska Manualer
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
Vault Manualer
- Vault Philips
- Vault Thule
- Vault Nedis
- Vault Abus
- Vault Burg Wächter
- Vault Dometic
- Vault Honeywell
- Vault Topcraft
- Vault Master Lock
- Vault Yale
- Vault Juwel
- Vault Olympia
- Vault Westfalia
- Vault Olymp
- Vault Perel
- Vault Fluke
- Vault SentrySafe
- Vault Avanti
- Vault SereneLife
- Vault First Alert
- Vault Kidde
- Vault Toolland
- Vault Salvus
- Vault Hard Head
- Vault Guzzanti
- Vault First Austria
- Vault Phoenix
- Vault Challenge
- Vault Conrad
- Vault Varo
- Vault Sentry
- Vault Filex
- Vault Kreator
- Vault Handson
- Vault Nauta
- Vault Royal Safe
- Vault Jewel
- Vault Sistec
- Vault SMC
- Vault FireKing
- Vault Duralock
- Vault Tulox
- Vault Rottner Tresor
- Vault Oxloc
- Vault Suncast
- Vault Winholt
- Vault Protector
- Vault Homak Security
- Vault NOFIRE
- Vault Technomax
- Vault Kreator-Varo
- Vault M-Locks
- Vault Fichero
- Vault EasySafe
- Vault ROMA
- Vault Stamony
Nyeste Vault Manualer
19 December 2024
14 December 2024
14 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024