Barska AX11898 Manual

Barska Vault AX11898

Læs nedenfor 📖 manual på dansk for Barska AX11898 (2 sider) i kategorien Vault. Denne guide var nyttig for 11 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
See reverse side for more information
5/13
BC344
1. INSTALL BATTERIES
1. Remove Battery Compartment (B) cover
2. Insert 4 AA batteries and restore battery cover
2. FINGERPRINT REGISTRATION
IMPORTANT:
The safe is in Factory Default mode, ANY fingerprint can
open the safe. Only successful registered fingerprint can
terminate Factory Default mode
1. With safe door open, press and release Initialization
Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- 1 beep will be heard recognizing the fingerprint; followed by
2 consecutive beeps
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when a total of 3 beeps are heard
Unsuccessful Registration
2 short beeps will be heard; repeat registration process again
3. To register another fingerprint – repeat steps 1 - 2
3. TEST A REGISTERED FINGERPRINT
1. With safe door open, turn Handle (H) counter clockwise to
lock the safe
- Press and release Wake-Up Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should not open
2. If the Handle (H) turned with a non-registered fingerprint,
registration was unsuccessful; and safe remains in Factory
Default mode
- Repeat steps under FINGERPRINT REGISTRATION
3. Press and release Wake-Up Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should open
4. CLOSE/OPEN SAFE DOOR
CLOSE: Close door
- Turn Handle (H) counter clockwise to lock the safe
OPEN: Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
5. BEEP SOUND OPTIONS
Beep OFF: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
– RELEASE the Initialization Button
Beep ON: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
followed by 1 beep – RELEASE the Initialization Button
6. OPEN SAFE WITH EMERGENCY KEY
1. To expose the Emergency Key access, remove Logo
Plate (G) screws with provided Allen wrench
2. Insert Emergency Key into key access, push and turn key
counter clockwise, and turn Handle (H) clockwise to open
the safe
NOTE: Store Emergency Keys in a secure place, NOT inside
of the safe
7. OPEN SAFE WITH EXTERNAL BATTERY PACK
Use this option when internal batteries are low
1. Insert 4 AA batteries
2. Plug into External Battery Access (J)
3. Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
8. DELETE ALL STORED FINGERPRINTS /
RESET TO FACTORY DEFAULT MODE
1. Open safe, remove Battery Compartment (B) cover and
all 4 AA batteries
2. Press and release Wake-Up Button (F) a few times until no
beeps are heard
3. Press and HOLD the Initialization Button (A)
- Re-insert batteries, on the 4th battery you will hear 1
beep, followed by 2 consecutive beeps indicating safe is
in Factory Default mode
4. RELEASE Initialization Button (A)
5. Repeat steps 1-3 if a total of 3 beeps are not heard
6. Restore Battery Compartment (B) cover
7. All fingerprints stored in the safe have been deleted
NOTE: The safe is in Factory Default mode, ANY fingerprint
can open the safe
F
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
F. Wake-Up Button
G. Logo Plate and Emergency
Key Access
H. Handle
I. External Battery Pack
(batteries not included)
J. External Battery Access
* Actual model may vary
A
B
C
D
E
G
HH
HJ
I
L
o
c
k
U
n
l
o
c
k
WARNING
- New Safe is in Factory Default mode, ANY fingerprint
can open the safe. Only successful registered
fingerprint can terminate Factory Default mode.
- Register at least two different fingerprints and test a
few times before closing the safe door.
- Test with a non-registered fingerprint. If the safe
opens, the safe remains in Factory Default mode.
- Avoid leaving safe door open and unattended; it will
allow unauthorized individuals to add their fingerprints
and/or reprogram the safe, gaining full access to the
safe and the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the
safe, test registered fingerprints every 6 months.
Read all instructions before using this safe.
Users Manual for Biometric Safe
F


Produkt Specifikationer

Mærke: Barska
Kategori: Vault
Model: AX11898

Har du brug for hjælp?

Hvis du har brug for hjælp til Barska AX11898 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vault Barska Manualer

Barska

Barska AX11820 Manual

25 August 2024
Barska

Barska AX13368 Manual

25 August 2024
Barska

Barska CB11794 Manual

25 August 2024
Barska

Barska AX11646 Manual

25 August 2024
Barska

Barska AX11970 Manual

25 August 2024
Barska

Barska AX11650 Manual

25 August 2024
Barska

Barska CB11784 Manual

25 August 2024
Barska

Barska AX11780 Manual

25 August 2024
Barska

Barska AX11838 Manual

25 August 2024
Barska

Barska AX12842 Manual

25 August 2024

Vault Manualer

Nyeste Vault Manualer

Stamony

Stamony ST-KS-100N Manual

15 Oktober 2024
Stamony

Stamony ST-KB-200 Manual

15 Oktober 2024
Phoenix

Phoenix FS1512 Manual

14 Oktober 2024
Phoenix

Phoenix CB0102K Manual

14 Oktober 2024
Phoenix

Phoenix FS1911 Manual

14 Oktober 2024
Phoenix

Phoenix GS8017 Manual

14 Oktober 2024
Phoenix

Phoenix HS3554 Manual

5 Oktober 2024
Phoenix

Phoenix HS6076 Manual

5 Oktober 2024