Barska AX11898 Manual
Læs nedenfor 📖 manual på dansk for Barska AX11898 (2 sider) i kategorien Vault. Denne guide var nyttig for 11 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
See reverse side for more information
5/13
BC344
1. INSTALL BATTERIES
1. Remove Battery Compartment (B) cover
2. Insert 4 AA batteries and restore battery cover
2. FINGERPRINT REGISTRATION
IMPORTANT:
The safe is in Factory Default mode, ANY fingerprint can
open the safe. Only successful registered fingerprint can
terminate Factory Default mode
1. With safe door open, press and release Initialization
Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- 1 beep will be heard recognizing the fingerprint; followed by
2 consecutive beeps
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when a total of 3 beeps are heard
Unsuccessful Registration
2 short beeps will be heard; repeat registration process again
3. To register another fingerprint – repeat steps 1 - 2
3. TEST A REGISTERED FINGERPRINT
1. With safe door open, turn Handle (H) counter clockwise to
lock the safe
- Press and release Wake-Up Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should not open
2. If the Handle (H) turned with a non-registered fingerprint,
registration was unsuccessful; and safe remains in Factory
Default mode
- Repeat steps under FINGERPRINT REGISTRATION
3. Press and release Wake-Up Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should open
4. CLOSE/OPEN SAFE DOOR
CLOSE: Close door
- Turn Handle (H) counter clockwise to lock the safe
OPEN: Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
5. BEEP SOUND OPTIONS
Beep OFF: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
– RELEASE the Initialization Button
Beep ON: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
followed by 1 beep – RELEASE the Initialization Button
6. OPEN SAFE WITH EMERGENCY KEY
1. To expose the Emergency Key access, remove Logo
Plate (G) screws with provided Allen wrench
2. Insert Emergency Key into key access, push and turn key
counter clockwise, and turn Handle (H) clockwise to open
the safe
NOTE: Store Emergency Keys in a secure place, NOT inside
of the safe
7. OPEN SAFE WITH EXTERNAL BATTERY PACK
Use this option when internal batteries are low
1. Insert 4 AA batteries
2. Plug into External Battery Access (J)
3. Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
8. DELETE ALL STORED FINGERPRINTS /
RESET TO FACTORY DEFAULT MODE
1. Open safe, remove Battery Compartment (B) cover and
all 4 AA batteries
2. Press and release Wake-Up Button (F) a few times until no
beeps are heard
3. Press and HOLD the Initialization Button (A)
- Re-insert batteries, on the 4th battery you will hear 1
beep, followed by 2 consecutive beeps indicating safe is
in Factory Default mode
4. RELEASE Initialization Button (A)
5. Repeat steps 1-3 if a total of 3 beeps are not heard
6. Restore Battery Compartment (B) cover
7. All fingerprints stored in the safe have been deleted
NOTE: The safe is in Factory Default mode, ANY fingerprint
can open the safe
F
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
F. Wake-Up Button
G. Logo Plate and Emergency
Key Access
H. Handle
I. External Battery Pack
(batteries not included)
J. External Battery Access
* Actual model may vary
A
B
C
D
E
G
HH
HJ
I
L
o
c
k
U
n
l
o
c
k
WARNING
- New Safe is in Factory Default mode, ANY fingerprint
can open the safe. Only successful registered
fingerprint can terminate Factory Default mode.
- Register at least two different fingerprints and test a
few times before closing the safe door.
- Test with a non-registered fingerprint. If the safe
opens, the safe remains in Factory Default mode.
- Avoid leaving safe door open and unattended; it will
allow unauthorized individuals to add their fingerprints
and/or reprogram the safe, gaining full access to the
safe and the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the
safe, test registered fingerprints every 6 months.
Read all instructions before using this safe.
User’s Manual for Biometric Safe
F
Produkt Specifikationer
Mærke: | Barska |
Kategori: | Vault |
Model: | AX11898 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Barska AX11898 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Vault Barska Manualer
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
25 August 2024
Vault Manualer
- Vault Philips
- Vault Thule
- Vault Nedis
- Vault Abus
- Vault Burg Wächter
- Vault Dometic
- Vault Honeywell
- Vault Topcraft
- Vault Master Lock
- Vault Yale
- Vault Juwel
- Vault Olympia
- Vault Westfalia
- Vault Olymp
- Vault Perel
- Vault Fluke
- Vault SentrySafe
- Vault Avanti
- Vault SereneLife
- Vault First Alert
- Vault Kidde
- Vault Toolland
- Vault Salvus
- Vault Hard Head
- Vault Guzzanti
- Vault First Austria
- Vault Phoenix
- Vault Challenge
- Vault Conrad
- Vault Varo
- Vault Sentry
- Vault Filex
- Vault Kreator
- Vault Handson
- Vault Nauta
- Vault Royal Safe
- Vault Jewel
- Vault Sistec
- Vault SMC
- Vault FireKing
- Vault Duralock
- Vault Tulox
- Vault Rottner Tresor
- Vault Oxloc
- Vault Suncast
- Vault Winholt
- Vault Protector
- Vault Homak Security
- Vault NOFIRE
- Vault Technomax
- Vault Kreator-Varo
- Vault M-Locks
- Vault Fichero
- Vault EasySafe
- Vault ROMA
- Vault Stamony
Nyeste Vault Manualer
15 Oktober 2024
15 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024
14 Oktober 2024
5 Oktober 2024
5 Oktober 2024
1 Oktober 2024
1 Oktober 2024