1
D-Fi XLR RX Instructions Rev. 1
INSTRUCTIONS
The D-Fi XLR RX is a D-Fi wireless receiver. Further information is in the Quick Reference Guide for the D-Fi XLR Pack.
Disclaimer
The information and specifications contained in these instructions are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residual
installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Increase the separation between the equipment and receiver
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
4. Consult the dealer or an experienced radio/TV technician for help
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or
return a product. Refer to Contact Us at the end of these instructions for contact information.
Operation
To set the D-Fi channel on the D-Fi XLR RX:
1. Set the power switch to the ON position.
2. Press the <MENU> button repeatedly to cycle through channels 1–16.
Battery Power
Each D-Fi XLR RX comes with a rechargeable lithium-ion battery for cable-free operation.
Battery Charge Notes
Avoid depleting the battery below 10%.
For best results, charge the battery in a temperature between 32 °F (0 °C), and 95 °F (35 °C).
When charging the battery, keep the product at least 1 m from any open flame or hot plate.
If the battery is completely discharged, the device cannot be turned on immediately when the charger is
connected. Allow a depleted battery to charge for a few minutes before turning on the device.
While charging, the device may heat up. This is normal and should not affect the device’s lifespan or performance.
If the battery gets hotter than usual, the charger may stop charging.
Do not charge the batteries in a closed container.
Do not charge the battery for more than 24 hours.
Battery Run Time
The power indicator on the D-Fi XLR RX shows red when the battery is charging, and green when it is
fully charged.
Do not charge the batteries in a closed container.
Maximum Run Time Recharge Time
Up to 10 hours 2.5 hours


Produkt Specifikationer

Mærke: Chauvet
Kategori: Controller
Model: D-Fi XLR RX

Har du brug for hjælp?

Hvis du har brug for hjælp til Chauvet D-Fi XLR RX stil et spørgsmål nedenfor, og andre brugere vil svare dig




Controller Chauvet Manualer

Chauvet

Chauvet D-Fi USB 2 Manual

6 September 2024
Chauvet

Chauvet D-Fi USB 2×4 Manual

6 September 2024
Chauvet

Chauvet DMX-RT4 Manual

3 September 2024
Chauvet

Chauvet RFC-XL Manual

3 September 2024
Chauvet

Chauvet FC-W Manual

3 September 2024
Chauvet

Chauvet ShowXpress Manual

3 September 2024
Chauvet

Chauvet FC-T Manual

3 September 2024
Chauvet

Chauvet RFC Manual

3 September 2024
Chauvet

Chauvet D-Fi XLR TX Manual

3 September 2024
Chauvet

Chauvet D-Fi XLR RX Manual

3 September 2024

Controller Manualer

Nyeste Controller Manualer