Cotech 36-6078 Manual

Cotech Lettelse 36-6078

Læs nedenfor 📖 manual på dansk for Cotech 36-6078 (5 sider) i kategorien Lettelse. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/5
UNITED KINGDOM CUSTOMER SERVICE
tel 020 8247 9300 customerservice@clasohlson.co.uk www.clasohlson.co.uk 10 13 Market Place, Kingston upon Thames, Surrey, KT1 1JZe-mail internet postal
1
2
3
4
5
Ver. 20181204
Motion Sensor Ceiling Light
Art.no 36-6078
Please read theentire instruction manual before using theproduct and then save it for future
reference. Wereserve theright for any errors in text or images and any necessary changes
made to technicaldata. Intheevent of technical problems or other queries, please contact
our Customer Services.
Safety
Installation should only be carried out by aqualified electrician.
Theproduct is only intended for indooruse.
Theproduct must be installed in accordance with current safety regulations to prevent
life-threatening accidents.
Theproduct is intended for fixed installation.
Theproduct is intended for ceiling installation.
Installation
Fixings
If thesupplied fixings are not suitable for thematerial which your ceiling is made of,
use appropriate fixings which will guarantee afirm anchorage.
Activation range
Therange is controlled by DIP switches 1, 2 and 3
10–100 % of 6m
Duration of activation after motion detection
Theactivation time is controlled by DIP switches 4, 5 and 6
5 sec – 30min
Light sensor sensitivity
Thesensitivity is controlled by DIP switches 7, 8 and 9
2–50 lux oroff
Note: Thelux values are measured with thediffuser removed.
Whenthediffuser is fitted, thelux values are somewhatlower.
The luminous flux (brightness) of the ceiling light can be adjusted by setting
the DIP switches as shown in the table.
Luminous flux (lm) Power (W) 1 2
1100 15.5 − −
800 11.5 ON −
500 7.6 ON ON
Care and maintenance
Switch off thepower to theceiling light before cleaning. Clean thelight by wiping it with asoft,
dampcloth. Useamild detergent. Neveruse solvents or strong, abrasive cleaning agents.
Responsible disposal
This symbol indicates that this product should not be disposed of with general
household waste. This applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards caused by incorrect waste
disposal, theproduct must be handed in for recycling so that thematerial can
be disposed of in aresponsible manner. When recycling your product, take it to
your local collection facility or contact theplace of purchase. They will ensure
that theproduct is disposed of in anenvironmentally sound manner.
Specifications
Only intended for indoor use (IP44).
If theplastic diffuser is damaged it must be replaced.
Minimum distance from combustible material: 0.1m.
Warning: Makesure that thepower is shut off before
starting theinstallation.
Thelight source in this product must only be replaced by
themanufacturer, aqualified service facility or aqualified
technician.
Note: Ifyou need to drill into theceiling, make sure to avoid any concealed electrical wiring.
1. Open theceiling light by twisting thediffuser anticlockwise and removingit.
2. Remove theplate holding theLED light by undoing the3retaining screws.
3. Knock out one of thepre-cut cable entries andt thecablegland.
4. Pull thepower supply cable through thecablegland.
5. Fasten theceiling light directly to theceiling using the4outermost mounting holes or
fasten it to aceiling rose using the2 innermost mountingholes.
6. Connect thepower supply cable to theterminal block as shownbelow.
7. Re-assemble theceiling light in reverseorder.
Sensor
1. Light sensor
2. LED which comes on when
thesensor is activated
3. Controls for setting
theactivation range,
duration of activation and
light sensor sensitivity.
4. Out
5. In
Light fitting
Power supply 220240 VAC,
50/60 Hz
Light source Built in LED
Power 15.5W
IP rating IP44
Colour temperature 3000K
Colour rendition Ra 80
Luminous flux 1100lm
800 lm
500 lm
Operating temperature −30°C ~ +40°C
Diam 34cm
Sensor
Recommended
installation height 2.5–6m
Detection range 12m
Sensitivity 10, 25, 50,
75 or 100 %
Lighting time 5 sec, 30 sec,
90 sec, 3min,
20min or 30min
Light sensor 2, 10, 25,
50 lux oroff
Motion sensor 0.5–3m/s
Detection angle 360º
Relay output for connecting up to 14additional
ceiling lights (36-6077), which are all activated
simultaneously.
Maxload: 800W resistive, 400W inductive
This ceiling light (36-6078) can be
interconnected with and control
multiple ceiling lights of article number
36-6077.
ON
1 2


Produkt Specifikationer

Mærke: Cotech
Kategori: Lettelse
Model: 36-6078

Har du brug for hjælp?

Hvis du har brug for hjælp til Cotech 36-6078 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Lettelse Cotech Manualer

Cotech

Cotech IPC15A3A-D3 Manual

30 August 2024
Cotech

Cotech EMP701MD Manual

27 August 2024
Cotech

Cotech IPC30SA1A Manual

16 August 2024
Cotech

Cotech JF4011G Manual

14 August 2024
Cotech

Cotech RP120W Manual

10 August 2024
Cotech

Cotech 36-4137 Manual

8 August 2024
Cotech

Cotech WCVC012W10 Manual

5 August 2024
Cotech

Cotech TOE-12 Manual

5 August 2024
Cotech

Cotech 36-6078 Manual

5 August 2024

Lettelse Manualer

Nyeste Lettelse Manualer