Smoke detector
Art. no. 32-1988, 32-3381, 32-3382,
32-3383
Placing of smoke
detector
Do not put asmoke detector in the
following places
• Do not place asmoke detector in akitchen
with poor ventilation. Smoke and fumes from
thepreparation of food and baking can trigger
thealarm.
• Do not place smoke detector near fans or
ventilation conduits. Smoke could drift in their
direction instead of toward thesmoke detector.
• Do not place asmoke detector in agarage.
A car’s exhaust may trigger analarm.
• Do not place asmoke detector in very damp
spaces or aspace exposed to broad temperature
variations. A smoke detector should not be placed
in anarea where thetemperature is below 5 °C or
above 40 °C.
A smoke detector should not be painted.
Assembly
Test and care
1. Test thesmoke detector at least once every
month, and preferably once per week, e.g.,
when you house clean.
2. Always test thesmoke detector after returning
from holidays or after being away for aprolonged
period. The smoke detector can be tested with
thetest button or by blowing alittle smoke
toward thesmoke detector.
3. The smoke detector sounds as long as thetest
button is pressed down or as long as there is
smoke in it.
4. Make sure thebattery is correctly positioned. Replace
battery if thesmoke detector makes no noise.
5. Below thetest button is ared diode that blinks
1–2 times per minute. It shows that thesmoke
detector is working.
6. Wipe thesurface of thesmoke detector with
amoist cloth when needed. When cleaning
house, thesmoke detector may be vacuumed
slightly as you do house cleaning.
Switching off thealarm sound
(model 32-3383)
When asmoke detector is placed in, say, akitchen
thealarm may be sometimes set off unintentionally.
The alarm sound can then be shut off for about ten
minutes by pressing on thetest button. Two signals
are heard when thesmoke detector returns again to
its normal state.
Changing batteries
A battery lasts for about one year. About one month
before thebattery is completely discharged, thesmoke
detector will start to emit short signals at about
one-half minute intervals. It is then time to replace
thebattery. Once this is done thedetector will start
working again.
Battery: 9 V standard or alkaline battery, e.g.,
Duracell MN 1604, Eveready no. 522, 1222 or 216,
Gold Peak 1604 P.
Always test smoke thedetector after replacing
thebattery.
Full
battery
When
sound
heard
Replace
battery
Control
lamp
Blinks
1–2 times/
min
Blinks
without
interrup-
tion
Alarm signal +
blinks once per
minute
Alarm
signal
Interrupted
signal
Alarm
signal
Blinks + Alarm
signal once/min
Guarantee
The smoke detector has a5-year guarantee
calculated from day of delivery. The guarantee covers
material and manufacturing flaws and is limited to
new for old or repairs. The guarantee is valid provided
only that theinstructions are followed. Return
adefective smoke detector to vendor or importer
(address below) with indication of defect and battery.
Announcement from (Finnish)
Radiation Safety Centre
(Does not apply to optical smoke detector model
32-3382).
This smoke detector contains asmall amount of
radioactive substance – americium 241.
The Finnish Radiation Safety Centre has investigated
and approved theradiation safety of this type of
smoke detector. In said test, normal use of thesmoke
detector does not expose humans to doses harmful
to thehealth.
Normal use entails:
• Correct choice of where to place thedetector.
• Smoke detector is used in frequented places.
• Proper care of smoke detector, e.g., instructions
for replacing battery and for cleaning are followed.
• The smoke detector must not be used by
children. The smoke detector may be disposed of
with thehousehold rubbish.
• The approval number of theFinnish Radiation
Safety Centre and theimporters address are on
thelabel on thesmoke detector.
Bedroom Bedroom
Bedroom
Bedroom
Bedroom
Cellar
Place in ceiling 50 cm
from wall
On wall 15–20 cm
from ceiling
• The smoke detector should bee placed in
theceiling near bedrooms
• If thebedrooms are in different parts of
thedwelling, asmoke detector should be placed
in each room.
• In abuilding with several flats there should be
asmoke detector in every flat.
• Make sure thesound from thesmoke detector is
distinctly heard.
• The earlier your family is warned thegreater
thechance of saving family members and
salvaging property.
1. Remove
thebottom plate
by turning it
slightly.
2. Insert battery
and attach
theconnecting
wires.
3. Press thetest
button and hold
down afew
seconds to test
thealarm sound.
4. Next check that thered light diode is blinking afew
times per minute.
5. Attach thebottom plate to theceiling with
theenclosed screws. Then screw thesmoke
detector tightly to thebottom plate.
Connecting function
Pull cable (e.g. oval wire SKF 2×0.75 mm²) between
thesmoke detectors that shall be connected.
The smoke detectors should be connected in parallel.
Produkt Specifikationer
Mærke: | Deltronic |
Kategori: | Brandslukker |
Model: | D-1211 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Deltronic D-1211 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Brandslukker Deltronic Manualer
29 August 2024
29 August 2024
29 August 2024
28 August 2024
28 August 2024
Brandslukker Manualer
- Brandslukker Smartwares
- Brandslukker Elro
- Brandslukker Alecto
- Brandslukker Housegard
- Brandslukker Cotech
- Brandslukker First Alert
- Brandslukker Ajax
Nyeste Brandslukker Manualer
15 November 2024
27 September 2024
23 September 2024
28 August 2024
25 August 2024
15 August 2024
14 August 2024
14 August 2024
4 August 2024
3 August 2024