Dnipro Metamorph Manual


Læs nedenfor 📖 manual på dansk for Dnipro Metamorph (1 sider) i kategorien Syntese maskine. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
GLIDE GLIDE
REVERS
CLOCKSTOP CV IN
RESET
TRIGS
CV OUTS
GATE
GATE
GATE
GATE
CHANNEL 1 CHANNEL 2
STAGE 1
STAGE 2
STAGE 3
STAGE 4
CHANNEL 3
USER GUIDE V1.0
COMMON LAYOUT OVERVIEW
CONTROLS AND FUNCTIONS
HOW TO LINK TWO MODULES
GLIDE GLIDE
REVERS
CLOCKHOLD CV IN
RESET
TRIGS
CV OUTS
GATE
GATE
GATE
GATE
GLIDE GLIDE
REVERS
CLOCKHOLD CV IN
RESET
TRIGS
CV OUTS
GATE
GATE
GATE
GATE
CONTROLLERSEQUENCED
GLIDE GLIDE
REVERS
CLOCKHOLD CV IN
RESET
TRIGS
CV OUTS
GATE
GATE
GATE
GATE
CONTROLLERSEQUENCED
4
6
2
3
1
781011
1
2
3
4
5
6
7
8
9
11
5
9
Patch regular clock or any other triggers to this input to run and sync sequencer.
Use this input to reset sequence to 1-st step.
This four buttons selects stages and shows active one with light. If CLOCK input is patched, the current active stage will
depends on a sequencer. To adjust stage, hold stage button and rotate knobs on the current active row, or patch off
clock wire, to select active stages without holding.
Tap to activate user sequence (button starts to light with green). If clock is patched, Metamorph will play a factory
programmed sequence now. To programm your own sequence, hold a button for a second. The button starts to flash,
that means you are in program mode. Press stage buttons in oder you wish, the pattern can be really long. Press stage
button several times if you wish to make rests on this stage. After finishing, press SEQ button again, Metamorph will
memorize your sequence and will keep it in memory after power off. To play it, light SEQ button and patch clock to
CLOCK input.
Output trigger pulse each time the stage of the sequence changes.
Outputs +5v while current stage is active.
Tip: patch GATE OUT to REVERSE to make a sequencer run in pendulum mode.
When this input will receive a signal, the direction of the sequencer will change. This input will not work in User
Sequence mode.
Use this input to drive a sequencer and to select active stage with CV. This input accepts voltages from 0 to 5 v. When
CLOCK is patched, the CV input will sync to clock in a sample and hold fashion. This input will not work in User
Sequence mode.
Per channel glide control for sweeping between stages.
CV outputs for each channel. It can ouput voltages in different ranges, selectable with jumpers.
When this input receives signal, the sequencer will stop. To run it again, send gate to RESET IN or press stage select
button.
CLOCK INPUT
RESET
STAGE SELECT BUTTONS
USER SEQUENCE BUTTON
TRIGGERS OUTPUT
STAGE GATE OUTS
REVERSE
CV INPUT
GLIDE
CV OUTPUTS
HOLD
Master
Slave
CH 1CH 2
CH 3
-5v +5v
0v +6v
-2.5v +3.0v
0v +11v
Master
Output voltage jumpers
Master/Slave jumper
Link socket.
Power off your system. Connect dedicated link cable to link sockets on both modules. Set the jumper to “slave” on the
back of one module.
Turn power on. 4 stage buttons on a slave
Important!, both modules need to be powered from one common power bus.
module will lit for a second and then lit off. That means slave founds a master. If 4 lights remain, make sure your
master module is on and press any stage button on slave.
Now you have an eight step sequencer and doubled outputs. However, all inputs and User Sequence button works only
on master module.
Slave
(approximately)


Produkt Specifikationer

Mærke: Dnipro
Kategori: Syntese maskine
Model: Metamorph

Har du brug for hjælp?

Hvis du har brug for hjælp til Dnipro Metamorph stil et spørgsmål nedenfor, og andre brugere vil svare dig