Drayton RTS9 Manual
Læs nedenfor 📖 manual på dansk for Drayton RTS9 (2 sider) i kategorien Termostat. Denne guide var nyttig for 2 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
RTS Thermostat
Installation instructions
Models
RTS1: Standard heating thermostat
RTS2 Heating thermostat with call for heat LED indicator
RTS3: Indoor frost thermostat
RTS4 Volt free heating/cooling change over switch
RTS9 & 10: Volt free heating/cooling changeover switch with call
for heating LED indicator
IMPORTANT NOTE
RTS thermostats are ELECTRONIC with a relay output.
Unless connected to a 230V mains supply the relay will
not operate, no 'click' will be heard and the call for heat
contact will remain open.
Location
Care should be taken to mount the thermostat in a position
which is not subject to direct sunlight or draughts. Preferably
it should be mounted on an inside wall about 1.5m (5ft)
above the floor in a position where it can respond to room
temperature but away from the direct influence of radiators
or other appliances giving off heat.
Note: If the thermostat is to be used as a frost protection
device it should be located in the coldest part of the premises.
Fixing
1. Loosen the securing screws, remove the wall-plate and, if
surface wiring is to be used, snap out the cable entry strip
on the bottom edge of the wall-plate with a pair of pliers.
2. Fix the wall-plate, terminals at the top, either direct onto a
flat wall using wall plugs and No 6 x 1” woodscrews or on a
flush mounting single conduit box using M 3.5 x 14 screws.
3. Complete the wiring to the wall-plate in accordance with
the relevant diagram shown overleaf in accordance with
I.E.E. regulations.
Note: The thermostat is for fixed wiring only and is double
insulated, the earthing continuity (loop) terminal is only
provided for convenience.
4. Plug the thermostat onto the wall-plate and tighten the
securing screws.
5. Before switching on the mains ENSURE THE CIRCUIT
FUSE IS 3A.
WARNING
Disconnect mains supply before fitting or removing from
wall-plate.
A switch having contact separation of at least 3mm in all
poles must be incorporated in the fixed wiring as a means
of providing full disconnection of the mains supply.
Setting
1. Set the desired room temperature on the control knob
against the setting mark.
2. The setting range may be limited or a particular setting
locked through the use of the mechanism to be found
under the control knob.
3. To adjust the limiters firstly set the thermostat to the
desired temperature and then carefully pull off the knob.
4. Lift and rotate the two limiting arms to re-position them in
the required notches.
5. Replace the knob with the previously set temperature
against the setting mark.
Technical data
Electrical supply: 230V ac 50Hz fused 3A
Double insulated (no earth required)
Temp. range: RTS1, 2, 4 & 9 10 to 30 C° °
RTS3 (Frost) 3 to 10 C° °
Switch type: 3 S.P.S.T 2(1)A 230V ac live RTS 1, 2 &
output
RTS4, 9 & 10 eS.P.D.T 2(1)A 230V ac volt fre
Temp. sensor: Electronic
RTS10 14 to 30 C° °
Produkt Specifikationer
Mærke: | Drayton |
Kategori: | Termostat |
Model: | RTS9 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Drayton RTS9 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Termostat Drayton Manualer
5 Oktober 2024
16 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
Termostat Manualer
- Termostat Bosch
- Termostat SilverCrest
- Termostat Siemens
- Termostat GE
- Termostat Panasonic
- Termostat Hager
- Termostat TP-Link
- Termostat AEG
- Termostat Gigaset
- Termostat Finder
- Termostat Atag
- Termostat Emos
- Termostat Google
- Termostat Worcester
- Termostat TFA
- Termostat Baxi
- Termostat Carel
- Termostat De Dietrich
- Termostat Buderus
- Termostat AVM
- Termostat Hama
- Termostat Theben
- Termostat Busch-Jaeger
- Termostat Trotec
- Termostat Honeywell
- Termostat Ariston Thermo
- Termostat Truma
- Termostat Elro
- Termostat Max
- Termostat Vaillant
- Termostat Carrier
- Termostat Danfoss
- Termostat Wolf
- Termostat Nest
- Termostat Dimplex
- Termostat Eberle
- Termostat Grässlin
- Termostat Heimeier
- Termostat Junkers
- Termostat Salus
- Termostat TrickleStar
- Termostat Weishaupt
- Termostat Alecto
- Termostat Westfalia
- Termostat Boneco
- Termostat HQ
- Termostat EnerGenie
- Termostat Schneider
- Termostat Basetech
- Termostat Tesla
- Termostat Grohe
- Termostat Ferroli
- Termostat Velleman
- Termostat Perel
- Termostat Joblotron
- Termostat Saunier Duval
- Termostat JUNG
- Termostat Vemer
- Termostat ORNO
- Termostat Watts
- Termostat Netatmo
- Termostat Technoline
- Termostat Somfy
- Termostat EQ3
- Termostat Techno Line
- Termostat Brennenstuhl
- Termostat Cotech
- Termostat Intergas
- Termostat Devolo
- Termostat Aube
- Termostat Elgato
- Termostat Renkforce
- Termostat SPC
- Termostat Hunter
- Termostat Viessmann
- Termostat Nobo
- Termostat Orbis
- Termostat Remeha
- Termostat Seitron
- Termostat Stiebel Eltron
- Termostat ACV
- Termostat Mikoterm
- Termostat Hive
- Termostat Tado
- Termostat Fibaro
- Termostat Noma
- Termostat POER
- Termostat EQ-3
- Termostat Vimar
- Termostat Oregon Scientific
- Termostat Corbero
- Termostat Remko
- Termostat Nexa
- Termostat Avidsen
- Termostat Crestron
- Termostat Emerson
- Termostat Elektrobock
- Termostat Delta Dore
- Termostat Homematic IP
- Termostat H-Tronic
- Termostat Schwaiger
- Termostat Emko
- Termostat Bearware
- Termostat Ferguson
- Termostat Nefit
- Termostat Amfra
- Termostat Itho
- Termostat Fenix
- Termostat Magnum
- Termostat Horstmann
- Termostat Oventrop
- Termostat King
- Termostat Arnold Rak
- Termostat Heatmiser
- Termostat Itho-Daalderop
- Termostat Bticino
- Termostat Sygonix
- Termostat Plieger
- Termostat Conrad
- Termostat Zehnder
- Termostat Bulex
- Termostat UPM
- Termostat Optima
- Termostat AWB
- Termostat Xavax
- Termostat Fantini Cosmi
- Termostat Niko
- Termostat Gira
- Termostat Eneco
- Termostat Frico
- Termostat Vasco
- Termostat Radson
- Termostat Go Green
- Termostat Extraflame
- Termostat ICY
- Termostat HomeMatic
- Termostat Computherm
- Termostat Brink
- Termostat Heatit
- Termostat 2Heat
- Termostat Bryant
- Termostat Eqiva
- Termostat Etherma
- Termostat Veria
- Termostat Emmeti
- Termostat Thermy
- Termostat Coati
- Termostat Essent
- Termostat ThermoSmart
- Termostat Plugwise
- Termostat Eurotronic
- Termostat Hornbach
- Termostat Tru Components
- Termostat HomePilot
- Termostat Muller
- Termostat Worcester-Bosch
- Termostat Econo-Heat
- Termostat VDH
- Termostat PECO
- Termostat IR-V
- Termostat EasyTemp
- Termostat Intertechno
- Termostat Helios (Amfra)
- Termostat Easy Timer
- Termostat Z-Wave
- Termostat Hugo Muller
- Termostat IMIT
- Termostat Innogy
- Termostat Wallair
- Termostat Maico
- Termostat Levica
- Termostat Ouellet
- Termostat THERMAFLEX
- Termostat Wachendorff
- Termostat STI
- Termostat Yokis
- Termostat ChiliTec
- Termostat Eliwell
- Termostat Johnson Control
- Termostat Webasto
- Termostat Drayton Erie
- Termostat OJ ELECTRONICS
- Termostat Tellur
- Termostat RWE
- Termostat Lowes
- Termostat Jumo
- Termostat Warmup
- Termostat Qubino
- Termostat ELKO
- Termostat Gewiss
- Termostat Sinustec
- Termostat Rose LM
- Termostat Otio
- Termostat MundoControl
- Termostat Enda
- Termostat GENERAL Life
- Termostat Oreg
- Termostat Braeburn
Nyeste Termostat Manualer
11 November 2024
11 November 2024
11 November 2024
11 November 2024
9 November 2024
9 November 2024
9 November 2024
9 November 2024
6 November 2024
15 Oktober 2024