Ebro TTX 200 Manual

Ebro Termometer TTX 200

Læs nedenfor 📖 manual på dansk for Ebro TTX 200 (2 sider) i kategorien Termometer. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
*926.007 DIGITAL THERMOMETER - MANUAL
926007 G20ED 1/2
T
T
T
T
T
T
T
T
T
T
X
X
X
X
X
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
T
T
T
T
T
y
y
y
y
y
p
p
p
p
p
e
e
e
e
e
T
T
T
T
T
C
C
C
C
C
o
o
o
o
o
r
r
r
r
r
e
e
e
e
e
T
T
T
T
T
h
h
h
h
h
e
e
e
e
e
r
r
r
r
r
m
m
m
m
m
o
o
o
o
o
m
m
m
m
m
e
e
e
e
e
t
t
t
t
t
e
e
e
e
e
r
r
r
r
r
O
O
O
O
O
p
p
p
p
p
e
e
e
e
e
r
r
r
r
r
a
a
a
a
a
t
t
t
t
t
i
i
i
i
i
n
n
n
n
n
g
g
g
g
g
I
I
I
I
I
n
n
n
n
n
s
s
s
s
s
t
t
t
t
t
r
r
r
r
r
u
u
u
u
u
c
c
c
c
c
t
t
t
t
t
i
i
i
i
i
o
o
o
o
o
n
n
n
n
n
s
s
s
s
s
Congratulations on the purchase of the p We hope that you can make use of this product for a long time and it roduct.
helps you with your work. Powered by a replaceable lithium battery, the thermometer is a handy, temperature
measurement device for a e range of measurement and control applications. whol
LCD
ON/HOLD
Thermocouple Probe
Battery Cover
OPERATION
1. Power on
To switch the thermometer on,
k ON/HOLD ( ) pressedeep
for approximately one second.
2. Display LCD
All necessary information is
displayed on the LCD. The individual symbols have
the following meanings:
2.1 Display for current
measured values
2.2 Minus sign
(negative measured values)
2.3 Battery status indicator
2.4 HOLD Auto shut down after 10 minutes --
2.5 Temperature unit
3. Select the required unit of measurement °C or °F:
Switch on the device by pressing ON/HOLD (荜 荜). As soon "Ebro" is shown, press ON/HOLD ( ) again for 3
seconds and release. The settings menu is active and the current unit is shown.
Press ON/HOLD ( ) once, the display will switch to next unit.
Press ON/HOLD ( for more than 2 sec, the current unit will be stored, and then the settings menu will be left.)
4. Measuring temperature
4.1 As soon as switch on the device, start to take a temperature reading every second.
4.2 Press ON/HOLD ( ) once, the device stops measuring and the last reading is shown on the LCD.
“HOLD” is shown on the LCD.
4.3 Press ON/HOLD ( ) again, the device starts measuring again.
* The last measured value is frozen and the thermometer deactivates itself automatically after about 10 minutes to
save battery power.
CAUTION
The thermometer should be protected from the following:
1. Electro Static Discharge
2. ”Thermal shock” caused by large or abrupt ambient temperature changes.
- allow 30 minutes for unit to stabilize before use when exposed to “thermal shock”.
3. e. Do not leave the unit on or near objects of high temperatur
4 K. eep out of reach of all children.
STORAGE & CLEANING
Clean the device with a damp cloth. Do not use any solvents such as Acetone as they corrode the plastic. Isopropyl alcohol may be
used to disinfect. Do not submerge any part of the thermometer. The thermometer should be stored at room temperature
between 20 to + (-4~149°F). 65°C
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
ˬ ˭
ˬ ˭
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. The
thermometer
should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room
temperature.
‘Er3’ is displayed when the ambient temperature exceeds -20
o
C(-4° or +F) 60
o
C(140°F).
ˬ ˭
Error 5~9, for a
ll other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on.
the error message remains please contact the Service Department for further assistance.
ˬ ˭ˬ
˭
‘ ’Hi or Lo is displayed when the temperature being measured is outside of the measurement range.
BATTERy
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements are
not possible
BATTERY REPLACEMENT
When the icon indicates the battery is low, the battery should be replaced immediately with a CR2450 lithium cell. The Low Battery
battery is located under the twist cover at the rear of the thermometer. Please note: It is important to turn the instrument off before
replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery properly and keep away from children.
SPECIFICATION
Measurement Range
Operating Range
Accuracy
Resolution
Battery Life
Dimensions
Needle
Weight
Caution: Please make sure the target to be measured will not exceed the temperature range of the probe to avoid
permanent damage of the thermocouple probe.
Caution: To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding 24V
AC RMS or 60V DC with the thermocouple probe.
EMC/RFI
I
I
I
I
: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* IP65 Splash Proof


Produkt Specifikationer

Mærke: Ebro
Kategori: Termometer
Model: TTX 200

Har du brug for hjælp?

Hvis du har brug for hjælp til Ebro TTX 200 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer Ebro Manualer

Ebro

Ebro TFI 550 Manual

22 August 2024
Ebro

Ebro TLC 700 Manual

16 August 2024
Ebro

Ebro TLC 1598 Manual

14 August 2024
Ebro

Ebro TFX 420 Manual

14 August 2024
Ebro

Ebro TTX 200 Manual

11 August 2024
Ebro

Ebro TTX 110 Manual

10 August 2024
Ebro

Ebro TMX 420 Manual

10 August 2024
Ebro

Ebro TFX 410 Manual

9 August 2024
Ebro

Ebro TMX 320 Manual

8 August 2024
Ebro

Ebro TFX 422C Manual

8 August 2024

Termometer Manualer

Nyeste Termometer Manualer