Emko ESM-9944-N Manual
Emko
Temperaturregulator
ESM-9944-N
Læs nedenfor 📖 manual på dansk for Emko ESM-9944-N (2 sider) i kategorien Temperaturregulator. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
ESM-9944-N / ESM-9945-N
COOKING CONTROLLERS
Electr cal W r ngs� � �
D mens ons� �
ESM-9945-N
SET
°C
°F
P
O1
O2
+ -
Temperature Un t Ind cator� �
Programm ng Mode Ind cator� �
Temperature Control Output Status
T me End Output Status�
Encoder Button
Temperature Ind cator�
Steam Output Status(ESM9945N)
T me nd cator� � �
Steam Start-Stop Button
(ESM9945N)
T me Start-Stop Button�
If cooking time is not active, starts
cooking time. If cooking time is
started, cooking time is cancelled
and buzzer is silenced.
Temperature Un t Ind cator� �
Front Panel Def n t on� � �
ESM-9945-N
SET
°C
°F
P
O1
O2
+ -
96 mm / 3.78 nch�
96 mm / 3.78 nch�
84 mm / 3.31 nch�
11.5 1mm / 0.45 nch�
Max mum 15 mm / 0.59 nch� �
Panel Cut-out
92 mm / 3.62 nch(m n)� �
92 mm / 3.62 nch(m n)� �
129 mm / 5.08 nch(m n)� �
129 mm / 5.08 nch(m n)� �
Panel Mount ng�
Access and Change Set Value
Temperature Set Value
Time Set Value
Note : If no operat on for 10 seconds, dev ce automat cally ex ts from Set Value Screen w thout sav ng the value.� � � � � �
Press encoder button
to observe the set value.
Turn left encoder button
to decrease or turn r ght �
to ncrease the set value.�
Press encoder button
to save new set value
and return ma n screen. �
+
°C
°F
P
O1
O2
++
Set Value Screen
SET
ESD-995 0-N
+
°C
°F
P
O1
O2
++
Ma n ScreenMa n Screen ��
+
°C
°F
P
O1
O2
++
Set Value Screen
+
°C
°F
P
O1
O2
++
Press encoder button
to observe the set value.
SET
+
°C
°F
P
O1
O2
++
Set Value Screen
Press encoder button
to save new set value
and return main screen.
Turn left encoder button
to decrease or turn right
to increase the set value.
SET
Ma n Screen�
+
°C
°F
P
O1
O2
++
SET
Set Value Screen
+
°C
°F
P
O1
O2
++
Ma n Screen�
+
SET
°C
°F
P
O1
O2
++
ESM-9944-N / ESM-9945-N Cook ng Controllers�
- 4 d g ts d splay� � �
- J type Thermocouple Input or
K type Thermocouple Input or
R type Thermocouple Input or
S type Thermocouple Input or
2 or 3 w re PT 100 Input �
- Adjustable Process Offset Value
- Programmable ON/OFF, P, PI, PD ve PID control types
- Adaptat on of PID coeff c ents to the system by Auto Tune/Self Tune� � �
- Work ng t me select on n m nutes or seconds� � � � �
- Vo ced warn ng v a nternal buzzer� � � �
- Cover sw tch nput� �
- Steam output (ESM-9945-N)
ESM-9944-N / ESM-9945-N cook ng controllers are ma nly used for Bakery � �
appl cat ons, fermantat on cab nets, ceram cs and glass ovens, gra n dr er � � � � � � �
cab net, ndustr al fryer, ncubators. Accurate and advanced controll ng s � � � � � �
performed w th selectable ON-OFF, P, PI, PD ve PID, Self-Tune PID, Auto-�
Tune PID funct ons.�
DISPLAY
Temperature D splay:� 16 mm Red 4 d g ts LED D splay� � �
Led Ind cators:� O1 (Temperature Control Output Status LED), O2 (T me Control �
Output Status LED), Steam Output LED(ESM-9945-N), T me Ind cator, � �
Temperature Ind cator, P(Programm ng Mode LED),ºC, ºF LEDs� �
OUTPUT
Temperature Control Output : Relay (7A@250V at res st ve load) or opt onal V� � �
SSR Dr ver Output (Max mum 10mA, 17V )� � Z
T me Output : �Relay (5A@250V at res st ve load) or opt onal SSR Dr ver V� � � �
Output (Max mum 10mA, 17V )�Z
Steam Output(ESM-9945) : Relay (5A@250V at res st ve load) or opt onal V� � �
SSR Dr ver Output (Max mum 10mA, 17V )� � Z
Bes des these, there � �s an �nternal buzzer for vo ced warn ng.� �
SPECIFICATIONS
INPUT
Process Input: TC/RTD
Thermocouple (TC): J, K, R and S (IEC584.1)(ITS90)
Thermores stance (RTD):� 2 or 3 w re Pt100 ( IEC 751) (ITS90)�
Measurement Range: Please refer to parameter n parameters sect on.� �
Accuracy: ± 0.25% of scale for thermocouple and thermores stance.�
Cold Junct on Compensat on:� � Automat cally ±0.1°C/1°C�
L ne Compensat on: � � Max mum 10 Ohm�
Sensor Break Protect on:� Upscale
Sampl ng Cycle: �0.1 second
CONTROL
Control Forms: ON/OFF, P, PI, PD veya PID (Control form can be
programmed by the user.)
SUPPLY VOLTAGE
230V (±15%) 50/60Hz - 3VAV
115V (±15%) 50/60Hz - 3VAV
24V (±15%) 50/60Hz - 3VAV
(Must be determ ned � �n order.)
ENVIRONMENTAL RATINGS and PHYSICAL SPECIFICATIONS
Operat ng Temperature:� 0...50ºC
Hum d ty :� � 0-90%RH (none condens ng)�
Protect on Class: �IP65 at front , IP20 at rear
We ght: � 370 gr.
D mens on: � � 96 x 96 mm, Depth: 100 mm
Panel CutOut: 92 x 92 mm
To reduce the effect of electr cal no se on dev ce, low voltage l ne (espec ally sensor � � � � �
� � � � �nput cables) w r ng must be separately from h gh current and voltage l ne. If
poss ble, use sh elded cable abd sh eld must be connected to ground only one s de.� � � �
Output-1
TC
PT-100
4 5 10 11 12 13 14 15
Output-2
7A@250V 5A@250V 5A@250VV V V
6 7 8 9
D g tal Input� �
Output-3
NCCNO CNO CNO
ESM-9945-N
CAT II
O2
(T me End �
Output)
O1
(Temperature Control
Output)
Supply
Voltage
Sw tch�
N
Supply
Voltage
L
1A T
S gorta�O3
(Steam
Output)
Cover
Sw tch�
Temperature
Sensor Input
Output-1
TC
PT-100
4 5 10 11 12 13 14 15
Output-2
7A@250V 5A@250VV V
6 7 8 9
D g tal Input� �
NCCNO CNO
ESM-9944-N
CAT II
O2
(T me End�
Output)
O1
(Temperature Control
Output)
Supply
Voltage
Sw tch�
N
Supply
Voltage
L
1A T
S gorta�Cover
Sw tch�
Temperature
Sensor Input
Instruct on Manual. ENG ESM-994X-N 01 V02 02/18�
1- Before mount ng the dev ce n your panel, make � � �
sure that the cutouts s of the r ght s ze.� � �
2- Check front panel gasket pos t on.� �
3- Insert the dev ce through the cutout. If the �
mount ng clamps are on the un t, put out them before � �
� � �nsert ng the un t to the panel.
4- Insert the mount ng clamps to the two of �
des gnated holes that located on four s des of dev ce.� � �
5- Drag the mount ng clamps n d rect on 5 unt l the � � � � �
dev ce completely mmob le w th n the panel.� � � � �
6- In order to remove dev ce push on the mount ng � �
clamp as shown w th arrow 6 and pull back.�
3
2
1
4
5
Access the Parameters
SET
+
°C
°F
P
O1
O2
++
Press encoder
button dur ng 10 seconds. �
Ma n Screen�
SET
+
°C
°F
P
O1
O2
++
Press encoder
button dur ng 10 seconds. �
Ma n Screen�
SET
If no pr vacy lock dent f cat on � � � � �
Parameters Screen w ll be �
observed. If pr vacy lock s � �
� � � �dent f ed, w ll be observed.
Press encoder button to access
Password Screen.
+
°C
°F
P
O1
O2
++
Enter the password using
encoder button. Turn left
encoder button to decrease or
turn right to increase value.
Approve password using
encoder button.
+
°C
°F
P
O1
O2
++
Password Screen
If Parameters Screen is
active, "P" led blinks. To
observe previous parameter,
turn encoder button left. To
observe next parameter, turn
encoder button right. Press
encoder button to observe
parameter value.
+
°C
°F
P
O1
O2
++
Parameters Screen
Produkt Specifikationer
Mærke: | Emko |
Kategori: | Temperaturregulator |
Model: | ESM-9944-N |
Har du brug for hjælp?
Hvis du har brug for hjælp til Emko ESM-9944-N stil et spørgsmål nedenfor, og andre brugere vil svare dig
Temperaturregulator Emko Manualer
30 August 2024
30 August 2024
30 August 2024
30 August 2024
28 August 2024
28 August 2024
28 August 2024
27 August 2024
27 August 2024
19 August 2024
Temperaturregulator Manualer
- Temperaturregulator Panasonic
- Temperaturregulator Hager
- Temperaturregulator IFM
- Temperaturregulator AEG
- Temperaturregulator Atag
- Temperaturregulator Carel
- Temperaturregulator Honeywell
- Temperaturregulator Ventus
- Temperaturregulator Dimplex
- Temperaturregulator Davis
- Temperaturregulator Voltcraft
- Temperaturregulator Kathrein
- Temperaturregulator JUNG
- Temperaturregulator Technoline
- Temperaturregulator Fluke
- Temperaturregulator Techno Line
- Temperaturregulator ACV
- Temperaturregulator AstralPool
- Temperaturregulator Cocraft
- Temperaturregulator SRS
- Temperaturregulator Inkbird
- Temperaturregulator Bulex
- Temperaturregulator Berker
- Temperaturregulator Ziehl
- Temperaturregulator Ygnis
- Temperaturregulator Wachendorff
- Temperaturregulator Jumo
Nyeste Temperaturregulator Manualer
16 December 2024
16 December 2024
15 December 2024
9 December 2024
5 December 2024
1 Oktober 2024
29 September 2024
20 September 2024
19 September 2024
18 September 2024