Extron XTP PI 100 Manual


Læs nedenfor 📖 manual på dansk for Extron XTP PI 100 (2 sider) i kategorien Netværkskort/adapter. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
1
XTP PI 100 (60-1233-01, 28-156-07LF)
Power Supply • Installation Guide
The Extron XTP PI 100 Power Injector supplies power to one XTP® Series extender,
IP Link Pro control processor, MediaLink® Plus controller, or TouchLink® Pro
touchpanel. This guide provides instructions for an experienced installer to install
and connect the XTP PI 100.
XTP
PWR
XTP PWR
100-240V 50/60 Hz
0.4A MAX
Rear Panel Front Panel
Installation
Step 1 — Mounting
ATTENTION:
These power supplies are not suitable for use in air handling spaces or in
wall cavities. The power supply must be located within the vicinity of the
Extron AV equipment in an ordinary location with pollution degree2, and
secured to an equipment rack within a dedicated closet, podium, or desk.
Ces sources d’alimentation ne sont pas appropriées pour une utilisation
dans les espaces d’aération ou dans les cavités murales. Cette source
d’alimentation doit être située à proximité de l’équipement audiovisuel
d’Extron, dans un endroit ordinaire avec une pollution IEC1010 degré2,
et xé à un équipement de rack au sein d’un placard, d’une estrade ou
d’un bureau qui lui est dédié.
The installation must be in accordance with the applicable provisions
of National Electrical Code ANSI/NFPA70, article725 and Canadian
Electrical Code part1, section16. The power supply must not be
permanently xed to building or similar structure.
Cette installation doit toujours être en accord avec les mesures qui
s’applique au National Electrical Code ANSI/NFPA70, article725, et au
Canadian Electrical Code, partie1, section16. La source d’alimentation
ne devra pas être xée de façon permanente à une structure de bâtiment
ou à une structure similaire.
The PI 140 is intended for indoor use only. No part of the network that
uses XTP remote power can be routed outdoors.
LePI140 est destiné à une utilisation en intérieur seulement. Aucune
partie du réseau qui utilise l’alimentation XTP à distance ne peut être
routée en extérieur.
Using the ZipClip 200
To attach the power supply to the ZipClip 200 mounting clip:
1. Insert the bottom of the power supply down into the clip, starting with one end.
2. Pivot the other end down and press until the clip
snaps into place.
To remove the power supply from the ZipClip:
1. Press the tab (1) on the ZipClip.
2. Pivot the power supply and lift it out of the
ZipClip (2).
To fasten the tie wraps for cable strain relief:
1. Attach the power supply to the
ZipClip 200 mounting clip as described
previously.
2. Fasten the power output cords to the
ZipClip base.
a. Insert tie wraps along the notches on
the side of the power supply and through the tie
wrap anchor points on the ZipClip, then around
the cord.
b. Connect and pull the tie wraps until they are
secure. Do not over tighten.
Mounting to a Rack Shelf
These power supplies are one-quarter rack
wide. Up to four power supplies can be
mounted side by side directly onto a rack shelf.
1. Align the threaded holes in
the bottom of the power
supply with the holes in an
Extron rack shelf. Fasten
the supply to the shelf
with two 4-40 x 3/16 inch
screws (1) as shown on
the right.
2. Bolt the rack shelf to the rack (2).
Furniture Mounting
NOTE: The ZipClip is shipped with
a set of four wood screws.
1. Attach the ZipClip to the furniture
using two or more wood screws as
shown at right (1). Make sure the clip
is oriented with the appropriate side
facing the mounting surface and with
the tab accessible from the front of
the furniture.
2. Insert the power supply into the
ZipClip as described previously and
press to snap it into place (2).
(2) 4-40 x 3/16"
Sc srew
RSB 312
Rack Shelf
Ra Mountedck
1
2
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
Tie Wrap
XTPPI100
ZipClip 200
100-240V
~
50-60Hz
0
.4A MA
X
100-240V
~
50-60Hz
0
.4A
MAX
XTP
PWR
XTP PWR
1
2
Mounting to Rack Rails Using a ZipClip
1. Fasten the ZipClip 200 mounting clip to a rack rail
using two rack screws as shown in the diagram on
the right.
2. Insert the bottom of the power supply down into
the clip, starting with one end.
3. Pivot the other end toward the clip and press until
the clip snaps into place.
ZipClip 200
Ba of Rackck
1
2
NOTE: Do not use two power injectors on the same cable run to remotely
power the transmitter and receiver. The diagram below shows this type of
application, which is not recommended by Extron.
POWE R
12V
INPUT S
2
--A MAX
RxT x
RS- 232 IR
RxT x
1NET
SIG LINK
ACT LINK
XT P OUT
OVE R XTP
AUDIO
CONT ACT RS - 232
T x Rx
XTP T USW 10 3
31 2 3
RES ET
LAN
ACT LINK
SIG LINK
XT P IN
POWE R
12V
OUT PUT S
HDMI
-- A MAX
RxT x
RS -23 2 IR
RxT x + −+
L R 1 2
OVER XTP
AUDIO
OFF
HDMI AUDIO
ON
S/PD IF
RELAYS
XTP SR HDMI
RES E T
REMOT E
RS- 2 32
T x Rx
XTP
PWR
XTP PWR
100-240V 50/60 Hz
0.4A MAX
XTP
PWR
XTP PWR
100-240V 50/60 Hz
0.4A MAX
CATx
XTP SR HDMI
CATx
CATx
XTP T 3USW 10
P 0XT PI 10
XTP 0PI 10
NOT RECOMMENDED
Important Safety Instructions
This symbol, when used on the product, is intended
to alert the user of important operating and
maintenance (servicing) instructions in the literature
provided with the equipment.
This symbol, when used on the product, is intended
to alert the user of the presence of uninsulated
dangerous voltage within the product enclosure
that may present a risk of electric shock.
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with a dry cloth.
Do not block any ventilation openings. Install in accordance with the
manufacturer instructions.
Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The
wide blade or the third prong is provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement
of the obsolete outlet.
Protect the power cord from being walked on or pinched, particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
Use only attachments and accessories specified by the manufacturer.
Unplug this device apparatus during lightning storms or when unused
for long periods of time.
CAUTION: Risk of electric shock. To reduce the risk
of fire or electric shock, do not expose this apparatus to rain,
moisture, dripping, splashing, or objects filled with liquids.
ATTENTION: Risque de choc électrique: Afin de
réduire les risques d’incendie ou de choc électrique, protégez
cet appareil de la pluie ou de l’humidité. Cet appareil doit être
conservé à l’abri des éclaboussures et des projections, et aucun
objet contenant un liquide, tel qu’un vase, ne doit être posé sur
l’appareil.
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as when
the power-supply cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
ATTENTION:
This apparatus is a Class I product. This product must be
connected to a mains socket outlet with a protective earthing
connection.
Cet appareil est un produit de Classe1. Ce produit doit
être connecté à une prise femelle secteur équipée d’une
connexion de mise à la terre.
The mains plug is used as the disconnect device and shall remain readily
operable.
To prevent the risk of shock, do not attempt to service this equipment
yourself because opening or removing covers may expose you to
dangerous voltage or other hazards.
ATTENTION:
Power sources • This equipment should be operated only from
the power source indicated on the product. This equipment is
intended to be used with a main power system with a grounded
(neutral) conductor. The third (grounding) pin is a safety feature.
Do not attempt to bypass or disable it.
[Source d’alimentation] • Ce matériel ne devrait être alimenté
qu’à partir de la source d’alimentation stipulée sur le produit.
Ce matériel est prévu pour être relié à un circuit d’alimentation
général doté d’un conducteur (neutre) mis à la terre. La troisième
broche (de terre) est un composant de sécurité. N’essayez pas
de l’éviter ou de la désactiver.
Power disconnection • To remove power from the equipment safely,
remove all power cords from the rear of the equipment, or the
desktop power module (if detachable), or from the power source
receptacle (wall plug).
connection de l’alimentation • Pour déconnecter le matériel de
sa source d’alimentation en toute sécurité, débranchez tous les
cordons d’alimentation de l’arrière du matériel ou débranchez
l’adaptateur secteur (si débranchable) ou de la prise secteur
(prise murale).
LED Indicators
A Front panel power LED indicator
Lights to indicate the XTP PI 100 is
receiving power.
B Rear panel PWR LED indicator
Indicates various power states of the
connected endpoints (see the table below).
LED State Port Status
Unlit The endpoint is not connected or cannot be powered.
Lit The endpoint is receiving power from the XTP PI 100.
Blinks ve times There is a power overload fault.
Blinks nine times The power allocation is exceeded.
NOTE: The blinking LED repeats the specified number of blinks from the
table above after a short interval of remaining unlit.
Step 2 — Cabling
ATTENTION:
zDo not connect these devices to a computer data or
telecommunications network.
zNe connectez pas ces appareils à des données informatiques ou à un
réseau de télécommunications.
For the best performance, see Twisted Pair Recommendations on page 2.
1. Connect a network switch, XTP extender, IP Link Pro control processor, or
MediaLink Plus controller to the XTP
port (A) of the power injector using a
straight-through cable. The device
plugged into this connector needs to
be powered by a local power source.
2. Connect an XTP extender, IPL Pro,
MLC Plus, or TouchLink Pro
touchpanel that requires remote
power to the XTP Pwr port (B)
using a straight-through cable.
3. Connect AC power to the XTPPI100 (C).
XTP
PWR
XTP PWR
100-240V 50/60 Hz
0.4A MAX
A
B
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To Network or
XTP device
To XTP, IPL Pro,
MLC Plus, or TLP Pro
device that can be
powered via EPo
AB
C


Produkt Specifikationer

Mærke: Extron
Kategori: Netværkskort/adapter
Model: XTP PI 100

Har du brug for hjælp?

Hvis du har brug for hjælp til Extron XTP PI 100 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Netværkskort/adapter Extron Manualer

Extron

Extron XTP PI 100 Manual

5 September 2024

Netværkskort/adapter Manualer

Nyeste Netværkskort/adapter Manualer

EQ-3

EQ-3 HM-CFG-LAN Manual

16 December 2024
SIIG

SIIG JU-WR0112-S2 Manual

15 December 2024
SIIG

SIIG JU-WR0212-S1 Manual

15 December 2024
Aukey

Aukey PA-U32 Manual

14 December 2024
Aukey

Aukey PA-Y18 Manual

14 December 2024
Digitus

Digitus DA-70835 Manual

13 December 2024
Digitus

Digitus DA-70841 Manual

13 December 2024
Digitus

Digitus DA-70842 Manual

13 December 2024
Digitus

Digitus DA-70840 Manual

13 December 2024