THERMISTEKTM Heat Alarm HT-630
THERMISTEKTM Heat Alarm with
Wireless Interlink WHT-630
6 7
After completing the ‘learn-in procedure,
test the alarms as described inALARM
TEST’. If any interlinked alarm fails to
respond to the ALARM TEST’, remove it
from its mounting plate and repeat the
‘learning-in’ process.
ALARM TEST
1. Briefly press the test button in the
centre and release.
2. The unit will give an audible alarm
consisting of 2 cycles of 3 loud beeps,
then stop automatically.
3. The red LED on the alarm will flash
rapidly during the audible signal.
As with all electronic alarm products you
should test your heat alarm every week, as
well as any other interlinked alarms.
WARNING: The electronic test button
provides a full test of the alarms
functionality. DO NOT try to test the alarm
with a naked flame, as this might present a
fire hazard in itself.
MAINTENANCE
Vacuum every three months to help keep
the unit working efficiently. Vacuum the
exterior. Prevent vacuum from touching
the unit.
WARNING: Never attempt to open or
damage the battery.
TROUBLESHOOTING
If your heat alarm chirps intermittently:
Check the location of your alarm.
If the alarm chirps every 45 seconds
and the yellow LED flashes at the same
time, this indicates that the battery is
low. Replace the unit within 30 days.
WHT-630 only: If the alarm chirps every
4 hours, another alarm in the network
has a low battery and needs replacing.
If the yellow LED is flashing and the alarm
is chirping:
If the yellow LED flashes at a different
time to the chirp, this means there’s
a fault with your alarm and it needs
replacing.
If your heat alarm does not sound during
testing:
Push the centre test button firmly.
If the unit has been silenced and is in
low sensitivity mode, it may not sound.
Wait 15 minutes.
Make sure the alarm is securely located
into the mounting plate.
If the alarm fails to operate correctly, the
advice of the manufacturer should be
sought by contacting Technical Support
on: 0330 094 5830. Fire & Rescue
customers, call: 0800 141 2561.
DISPOSAL
Waste electrical products should not be
disposed of with your other household
waste.
Your alarm does not contain any
radioactive material. This means that the
alarm is ideally suited for disposal within the waste
electronic and electrical equipment (WEEE) recycling
scheme. Please recycle where facilities exist. Check
with your local authority, retailer or contact our
technical support team for recycling/disposal advice
as regional variations apply. Once the alarm is
removed from the mounting plate the internal battery
will be deactivated. The unit is now ready for disposal.
WARNING: Do not attempt to open.
WARNING: Do not burn or dispose of in fire.
WARRANTY
FireAngel Safety Technology Limited warrants to
the original purchaser that its enclosed heat alarm
be free from defects in materials and workmanship
under normal residential use and service for a period
of 5 years from the date of purchase. Provided
it is returned with postage prepaid and proof of
purchase date, FireAngel Safety Technology Limited
hereby warrants that during the 5 year period
commencing from the date of purchase FireAngel
Safety Technology Limited, at its discretion, agrees to
replace the unit free of charge.
The warranty on any replacement HT-630/WHT-630
alarm, will last for the remainder of the period of the
original warranty in respect of the alarm originally
purchased – that is from the date of original purchase
and not from the date of receipt of the replacement
product. FireAngel Safety Technology Limited
reserves the right to offer an alternative product
similar to that being replaced if the original model is
no longer available or in stock. This warranty applies
to the original retail purchaser from the date of
original retail purchase and is not transferable. Proof
of purchase is required.
This warranty does not cover damage resulting
from accident, misuse, disassembly, abuse or lack
of reasonable care of the product, or applications
not in accordance with the user manual. It does not
cover events and conditions outside of FireAngel
Safety Technology Limited’s control, such as Acts of
God (fire, severe weather etc.). It does not apply to
retail stores, service centres or any distributors or
agents. FireAngel Safety Technology Limited will
not recognise any changes to this warranty by third
parties.
FireAngel Safety Technology Limited shall not be liable
for any incidental or consequential damages caused
by the breach of any expressed or implied warranty.
Except to the extent prohibited by applicable law, any
implied warranty of merchantability or tness for a
particular purpose is limited in duration for 5 years.
This warranty does not affect your statutory rights.
Except for death or personal injury, FireAngel Safety
Technology Limited shall not be liable for any loss of
use, damage, cost or expense relating to this product
or for any indirect or consequential loss, damages
or costs incurred by you or any other user of this
product. Please see the back cover of this guide for
contact details.
Please retain this user manual for future reference
TEST YOUR ALARM WEEKLY
(UK) technicalsupport@fireangeltech.com
(DE) technik@fireangeltech.com
(FR) supporttechnique@fireangeltech.com
(NL) klantenservice@fireangeltech.com
(INT) Internationalsupport@fireangeltech.com


Produkt Specifikationer

Mærke: FireAngel
Kategori: Røgdetektor
Model: FP1720W2-R

Har du brug for hjælp?

Hvis du har brug for hjælp til FireAngel FP1720W2-R stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgdetektor FireAngel Manualer

FireAngel

FireAngel ST-622 Manual

30 September 2024
FireAngel

FireAngel SB5-INT Manual

22 September 2024
FireAngel

FireAngel SW10-EUT Manual

15 September 2024
FireAngel

FireAngel HW10 Manual

31 August 2024
FireAngel

FireAngel SW1-R Manual

27 August 2024
FireAngel

FireAngel ST-750 Manual

27 August 2024
FireAngel

FireAngel SB1-T Manual

27 August 2024

Røgdetektor Manualer

Nyeste Røgdetektor Manualer

First Alert

First Alert HD6135FB Manual

14 Oktober 2024
Elro

Elro FS151021M Manual

8 Oktober 2024
Elro

Elro 2001-023 Manual

3 Oktober 2024
FireHawk

FireHawk FHB10 Manual

2 Oktober 2024
First Alert

First Alert SA410 Manual

1 Oktober 2024
König

König SAS-SA2002 Manual

1 Oktober 2024
Alecto

Alecto SA-49/1 Manual

29 September 2024
First Alert

First Alert SA710LCE Manual

29 September 2024