Inovonics EN1215WEOL Manual
Inovonics
Deur-/ramme sensor
EN1215WEOL
Læs nedenfor 📖 manual på dansk for Inovonics EN1215WEOL (2 sider) i kategorien Deur-/ramme sensor. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
8/22/19 357-05043-02 Rev A © Inovonics, 2019 - www.inovonics.com
EN1215WEOL Door/Window with Wall
Tamper and EOL
Installation Instructions
1 Overview
The Inovonics EN1215WEOL door/window with wall tamper and
EOL has a built-in magnetic reed switch on the side, with a
magnet that supports a 5/8" inch gap. The magnetic reed switch
can be used with both ferrous and non-ferrous material. A 2.2K
ohm end of line resistor is included with the EN1215WEOL, and
is required for operation.
The EN1215WEOL includes a back tamper switch. The tamper
condition must be defined within the control panel as a trouble
condition when the system is disarmed, and as an alarm
condition when the system is armed.
The door/window with wall tamper and EOL is available in North
America, Australia and New Zealand; the radio frequency band
has been configured for the appropriate geographic area at the
factory.
Note: For UL installations, refer to the EN4216MR Installation
and Operation Manual, the EN4232MR Installation and
Operation Manual, or the EN7290 EchoStream Receiver/
Interface for Honeywell VISTA Panels Installation Instructions.
The switch contact must also be located in the same room as the
EN1215WEOL, and the EN1215WEOL must be installed in
accordance with UL 681 and ULc S302.
Note: The cable length from the switch contact must not to
exceed 10 feet.
Caution: The EN1215WEOL contains both a wired input and an
input activated by a reed switch and magnet. The reed switch
and magnet must be used unless the application specifically
supports both inputs as separate devices. Use of the wired input
is optional.
1.1 Inovonics Contact Information
If you have any problems with this procedure, contact Inovonics
Wireless technical services:
• E-mail: support@inovonics.com.
• Phone: (800) 782-2709.
1.2 EN1215WEOL Internal Components
Figure 1 Door/window with wall tamper and EOL internal
components
1.3 What’s In The Carton
• Two wall mount screws.
• Two wall mount anchors.
• Two selection jumpers.
• One 3.0V lithium battery.
• One housing closure screw.
• One magnet.
• One 2.2K ohm end of line resistor.
2 Installation and Startup
2.1 Installation Notes
• These products are designed to be installed and maintained
by professional security technicians.
• Products are intended for indoor use.
• Manually test all products weekly.
2.2 Battery Installation
1. Use your thumb to press the housing release tab on the
bottom of the transmitter; separate the housing.
2. Install the battery.
3. Press the reset button to initialize the transmitter.
4. Test the transmitter and ensure appropriate response.
2.3 Select Input Type and Wire Resistor
The N/O-N/C selection pins allow the choice of a normally open
or normally closed state for the contact circuit wired to the input
terminal.
The transmitter is shipped set for normally open, with a selection
jumper on the N/O selections pins.
Set for normally open operation:
1. Place a selection jumper on the selection pins to select
normally open.
2. Use 22 AWG wire to wire the 2.2K ohm resistor in parallel
with the N/0 contact per Figure 2. The distance from the
external contact to the EN1215WEOL must not exceed 10
feet (3 meters).
3. Press the reset button to complete configuration.
Figure 2 Wired for N/O operation
Set for normally closed operation:
1. Remove the selection jumper from the selection pins.
2. Use 22 AWG wire to wire the 2.2K ohm resistor in series with
the N/C contact per Figure 3. The distance from the external
contact to the EN1215WEOL must not exceed 10 feet (3
meters).
3. Press the reset button.
Figure 3 Wired for N/C operation
2.4 Register the EN1215WEOL
Transmitters must be registered with the system in order to be
monitored and supervised. When supervised, the transmitter will
send a check-in message to the receiver every three minutes.
Each transmitter has a unique factory-programmed identification
number.
Refer to the system receiver’s documentation for details on
registering the transmitter.
1. When prompted by the receiver to reset transmitter, press
the reset button.
2. Replace the cover.
3. Test the transmitter and ensure appropriate response.
For product and installation videos visit us at
www.inovonics.com/videos or use the QR
code below.
ACombined housing/wall tamper
switch
BN/O - N/C jumper
C DInput terminal Reset button
EWall-mount screw holes FHousing closure screw hole
GReed switch
A
B
C
D
E
E
F
G
Produkt Specifikationer
Mærke: | Inovonics |
Kategori: | Deur-/ramme sensor |
Model: | EN1215WEOL |
Har du brug for hjælp?
Hvis du har brug for hjælp til Inovonics EN1215WEOL stil et spørgsmål nedenfor, og andre brugere vil svare dig
Deur-/ramme sensor Inovonics Manualer
18 August 2024
Deur-/ramme sensor Manualer
- Deur-/ramme sensor Emos
- Deur-/ramme sensor Abus
- Deur-/ramme sensor Hama
- Deur-/ramme sensor Optex
- Deur-/ramme sensor Smartwares
- Deur-/ramme sensor Vivanco
- Deur-/ramme sensor EZVIZ
- Deur-/ramme sensor König
- Deur-/ramme sensor ORNO
- Deur-/ramme sensor Somfy
- Deur-/ramme sensor Hikvision
- Deur-/ramme sensor Caliber
- Deur-/ramme sensor Fibaro
- Deur-/ramme sensor Nexa
- Deur-/ramme sensor Avidsen
- Deur-/ramme sensor Homematic IP
- Deur-/ramme sensor Schwaiger
- Deur-/ramme sensor KlikaanKlikuit
- Deur-/ramme sensor Xavax
- Deur-/ramme sensor X4-Tech
- Deur-/ramme sensor Interlogix
- Deur-/ramme sensor DSC
- Deur-/ramme sensor Satel
- Deur-/ramme sensor Kanlux
- Deur-/ramme sensor Tellur
- Deur-/ramme sensor Sonoff
- Deur-/ramme sensor Gewiss
Nyeste Deur-/ramme sensor Manualer
5 December 2024
6 September 2024
6 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024