- - - - - BA HUpro GB -22989 2014 07 V03 ED A3 Seite 1
GB
Additional instruction master clock 1 Site / 2
PLEASE NOTE!!!
SAFETY INSTRUCTIONS
(SC 58.17 pro / SC 98.47 pro / SC 53.17 pro / SC 93.47 pro)
Please note the following for masterclock with time switch functionality:
This manual describes only masterclock features. Time switch relevant description can be
found in the standard time switch manual!
Only the connection diagram, initial operations and the safety instructions of this manual is
valid.
!! !!ATTENTION DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!!
=> Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
=> Disconnect device from power supply for wiring and installation purposes!!!
=> Defective devices have to be put out of service immediately!!!
Connect the supply voltage/frequency as stated on the product!
Warranty void if housing opened by unauthorised person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if
external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with local building and electrical
codes!
The disposal of the device (and batteries) must be in accordance with the valid environmental and national law!
S – m ) C 58.07 pro (DIN rail mounting aster clock
Technical data slave- - clock line (SL)
Initial operation
SC 58.07 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 35mA
Conn. terminals: 17 / 18
Max. number clocks: approx. 5 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic -mode.
(Displaying the time and the current status of the slave clock- -line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave - -clock line is preset as follows: Minute-line
activated / start time 12:00 / Slave clock- -line (SL) is stopped.
Power supply master ( clock See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave clock- -line (SL) m => aster clock (See
connection diagram on the left)
Connect slave line to terminal no. 17 and 18 of the master clock.- -clock
SC 58.08 pro (DIN rail mounting – m aster clock)
Technical data slave- -clock line (SL)
Initial operation
SC 58.08 pro
Connection sample
Number of lines: 1
Output voltage: Max. 250V~ ( - ) potential free
Output current: 1A
Conn. terminals: 2 / 8
Max. number clocks: Depends on the slave clocks
Pulse sequence Normal operation = : 1/min
During adjustment = ca. 6/min
Pulse length: 8 sec.
(Pulse sequence/length adjustable)
PLEASE NOTE: The two relays are
energized alternately every minute.
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave clock- -line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave clock- -line is preset as follows: Minute-line
activated / start time 12:00 / Slave clock- -line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave clock- -line (SL) => master clock (See
connection diagram on the left)
Connect slave line to terminal no. 2 and 8 of the master clock.- -clock
Power supply slave-clock-line (SL) (See connection diagram on the left)
Connect power supply for clock motor(s) to terminals 1 / 9 and 3 / 7
SC 58.17 pro clock with time switch functianality / weekly time switch)(DIN rail mounting – m aster
Technical data slave- -clock line (SL)
Initial operation
SC 58.17 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 150mA
Conn. terminals: 17 / 18
Max. number clocks: approx. 20 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic -mode
(Displaying the time and the current status of the slave clock- -line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave cl- ock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave clock- -line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave clock- -line (SL) => master clock (See
connection diagram on the left)
Connect slave line to terminal no. 17 and 18 of the master clock.- -clock
SC 98.47 pro with time switch functianality / yearly time switch) (DIN rail mounting master clock
Technical data slave- -clock line (SL)
Initial operation
SC 98.47 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 300mA
Conn. terminals: 35 / 36
Max. number clocks: approx. 40 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave clock- -line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The - -slave clock line is preset as follows: Minute-line
activated / start time 12:00 / Slave clock- -line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
(M = aster clock terminals 22/23 / Time switch = terminals 4/5).
Connection slave clock- -line (SL) => master clock (See
connection diagram on the left)
Connect the slave- -clock line (SL) to the master clock on terminals 35 and 36
SC 53.17 pro (19”-housing – master clock with time switch functianality / weekly time switch)
Technical data slave- -clock line (SL)
Initial operation
SC 53.17 pro
Connection diagram
SC 53.17: 2 NU-Linie
The signal output for line 1 and line 2 can be configured
independently to emit pulses either every second or every minute!
NOTE! Power supply from a third party supplier:
The usage of a switched mode power supply to drive the slave clock line -
might disturb the reception of the FU 20.00 pro radio receiver. If the radio
receiver has no reception (the green LED on the bottom of the radio
receiver flashes rapidly or not at all) please connect GND of your
switched-mode power supply via an Y capacitor with protective earth.-
Number of lines: 2
Input U : SL 24VDC (12VDC/48VDC/60VDC)
( U - Monitoring SL switchable)
Output current: for each line up to 1500mA
(Depends on the power supply)
Conn. terminals: See conn. diagram on the left
Max. number clocks: approx. 200 slave clocks
(each line)
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
Module: ) NT 73 (Power adapter slave line
Not included in delivery!
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave clock- -line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave clock- -line is preset as follows: Minute-line
activated / start time 12:00 / Slave clock- -line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product! Terminals( 32a und 32c).
Connection power supply the slave- -clock line (SL) => master clock
(See connection diagram on the left)
Depending on the specifications of the slave clocks, connect 12VDC; 24VDC; 48VDC; or
60VDC to terminals 26a and 26c.
Check polarity.
For voltages of slave clocks which differ from 24VDC, the dip switches on the PCB have to
be configured as stated within the table on the left.
Connection slave clock- -line (SL) => master clock (See
connection diagram on the left)
Connect slave line to:- -clock
Line 1 [L1] => terminals 24a und 24c
Line 2 [L2] => terminals 22a und 22c
Table dip switches
(Power supply monitoring of the slave-clock-
line)
SL S1 S2
SL S1 S2
12VDC ON ON
48VDC OFF ON
24VDC ON OFF
60VDC OFF OFF
SC 93.47 pro (19” master clock ly time switch)-housing with time switch functianality / year
Technical data slave- -clock line (SL)
Initial operation
SC 93.47 pro
Connection diagram
NOTE! Power supply from a third party supplier:
The usage of a switched-mode power supply to drive the slave clock line
might disturb the reception of the FU 20.00 pro radio receiver. If the radio
receiver has no reception (the green LED on the bottom of the radio
receiver flashes rapidly or not at all) please connect GND of your
switched-mode power supply via an Y capacitor with protective earth.-
Number of lines: 1
Input USL: 24VDC (12VDC/48VDC/60VDC)
(Monitoring USL - switchable)
Output current: up to 1500mA
(Depends on the power supply)
Conn. terminals: See conn. diagram on the left
Max. number clocks: approx. 200 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
Module: NT 73 (Power adapter slave line)
Not included in delivery!
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave clock- -line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave clock- -line is preset as follows: Minute-line
activated / start time 12:00 / Slave clock- -line (SL) is stopped.
Power supply the master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product! Terminals( 32a und 32c)
C onnection power supply slave clockline => master clock
(See connection diagram on the left)
Depending on the specifications of the slave clocks, connect 12VDC; 24VDC; 48VDC; or
60VDC to terminals 26a and 26c.
Check polarity.
For voltages of slave clocks w
hich differ from 24VDC, the dip switches on the PCB have to
be configured as stated within the table on the left .
Connection slave clock- -line (SL) => master clock ( See
connection diagram on the left)
Connect slave line to terminal no. 24a and 24c of - -clock the master clock.
Table dip switches
(Power supply monitoring of the slave-clock-
line)
SL S1 S2
SC S1 S2
12VDC ON ON
48VDC OFF ON
24VDC ON OFF
60VDC OFF OFF