Orbit SunMate 62040 Manual
Orbit
Vandingskontrol
SunMate 62040
Læs nedenfor 📖 manual på dansk for Orbit SunMate 62040 (13 sider) i kategorien Vandingskontrol. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/13
START
START
START
START
START
INTERVAL
INTERVAL
INTERVAL
INTERVAL
INTERVAL DURATION
DURATION
DURATION
DURATION
DURATION
9
9
9
9
9
0
0
0
0
0
6
6
6
6
6
0
0
0
0
0
3
3
3
3
3
0
0
0
0
0
1
1
1
1
1
5
5
5
5
5
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
2
2
2
2
2
0
0
0
0
0
O
O
O
O
O
F
F
F
F
F
F
F
F
F
F
O
O
O
O
O
N
N
N
N
N
2
2
2
2
2
m
m
m
m
m
i
i
i
i
i
n
n
n
n
n
5
5
5
5
5
3
3
3
3
3
r
r
r
r
r
d
d
d
d
d
2
2
2
2
2
n
n
n
n
n
d
d
d
d
d
D
D
D
D
D
A
A
A
A
A
I
I
I
I
I
L
L
L
L
L
Y
Y
Y
Y
Y
1
1
1
1
1
2
2
2
2
2
h
h
h
h
h
r
r
r
r
r
8
8
8
8
8
h
h
h
h
h
r
r
r
r
r
4
4
4
4
4
t
t
t
t
t
h
h
h
h
h
7
7
7
7
7
t
t
t
t
t
h
h
h
h
h
O
O
O
O
O
N
N
N
N
N
C
C
C
C
C
E
E
E
E
E
2
2
2
2
2
h
h
h
h
h
r
r
r
r
r
4
4
4
4
4
h
h
h
h
h
r
r
r
r
r
Features
• One button sets time of day, another button sets watering
start time
• Two rotary dials for setting the watering interval and
watering duration.
• Battery operated (three AA), not included.
• Ten watering interval options (once, 2 hr, 4 hr, 8 hr, 12 hr, daily,
2nd day, 3rd day, 4th day, 7th day).
• Ten watering duration options (on, OFF, 2 min, 5 min,
10 min, 15 min, 30 min, 60 min, 90 min, 120 min).
• Manual watering without interrupting the watering interval.
• Weather resistant design.
• Dependable valve design.
• Low power consumtion soleniod.
Battery installation
Note:
Orbit recommends the use of Duracell®or Energizer®brand
AA alkaline batteries for optimum timer performance.
(see figure 1).
1. Remove the timer cover.
2. Pull the battery compartment out of the timer.
3. Install three AA alkaline batteries. Refer to the battery
compartment for the correct orientation of the batteries,
(see figure 1).
4. Place the battery compartment back in the timer.
• Three fresh AA alkaline batteries should last for an entire
watering season. When the battery voltage is below a safe
operating voltage the valve will not open. The batteries
s hould be replaced with new ones when this occurs.
5. Replace the timer cover to protect the timer from moisture
and debris.
Figure 1
Set the time of day and watering start time
• Press the Set Time button, holding it down for 2 seconds. The
digital readout will cycle through a.m. and p.m. time settings.
Release the Set Time Button just before the correct time of
day is reached. Tap the button to advance the time in 1
minute increments until correct time is reached.
• Press the Set Start button, holding it down for 2 seconds. The
digital readout will cycle through a.m. and p.m. time settings.
Release the Set Start button just before the desired watering
start time is reached. Tap the button to advance the time in 1
minute increments until desired start time is reached.
Note:
The timer valve will close when making entries using the Set
Time and Set Start buttons. Set Time and Set Start settings are
accepted by the timer 5 seconds after buttons are released,
except at the ON setting.
Set the watering start interval
Turn the Start Interval dial to the desired watering interval.
(see figure 2).
Note:
All Start Interval settings begin timing at the Set Start time
shown on the digital readout.
The Start Interval dial has ten possible settings:
• Once – the valve will open once for the amount of time on
the Duration dial and then remains inactive until the Start
Interval dial is rotated to another setting.
• 2 hr – the water will come on every two hours.
• 4 hr – the water will come on every four hours.
• 8 hr – the water will come on every eight hours.
• 12 hr – the water will come on every twelve hours.
• Daily – the water will come on once every day.
• 2nd day – the water will come on every other day.
Environmental Conditions
Working Temperature: 32 to 122°F
Storage Temperature: -14 to 140°F
Conditions environnementales
Température propre au fonctionnement : 0 à 50° (32 à 122°C F)
Température d’entreposage : -10 à 60°C (-14 à 140°F)
Condiciones ambientales
Temperatura de trabajo: 0 a 50°C (32 a 122°F)
Temperatura de almacenamiento: -10 a 60° (-14 a 140°F)C
HOSE FAUCET
HOSE WASHER
BRASS
CONNECTOR
AUTOMATIC HOSE
FAUCET V ALVE
COVER
TIMER
Dual Dial Hose Timer with Electronic Display
Minuterie numérique d’arrossage à deux boutons
Timer Digital de 2 cuadrantes para riego
Timer digitale per irrigazi one a 2 selettori
Digitale Bewässerungs-Zeitschaltuhr
mit zwei Drehschaltern
Orbit
®Irrigation Products, Inc.
845 North Overland Rd.
North Salt Lake, Utah 84054
PN 94050-24 Rev A © 2005 Orbit®Irrigation Products, Inc.
All rights reserved. All trade names
are registered trademarks of respective
manufacturers listed.
Model 62040, 27155, 94050 and 91050
Χρονόμετρο εύκαμπτου σωλήνα διπλού
διακόπτη με ηλεκτρονική ένδειξη
SUM252172 94050-24 rA 12/23/05 2:52 PM Page 1
Produkt Specifikationer
Mærke: | Orbit |
Kategori: | Vandingskontrol |
Model: | SunMate 62040 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Orbit SunMate 62040 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Vandingskontrol Orbit Manualer
12 August 2024
10 August 2024
10 August 2024
8 August 2024
6 August 2024
Vandingskontrol Manualer
- Vandingskontrol Gardena
- Vandingskontrol Vonroc
- Vandingskontrol Clas Ohlson
- Vandingskontrol Florabest
- Vandingskontrol Wolf Garten
- Vandingskontrol Woox
- Vandingskontrol Hozelock
- Vandingskontrol Kärcher
- Vandingskontrol Fiskars
- Vandingskontrol Westfalia
- Vandingskontrol Basetech
- Vandingskontrol Rain Bird
- Vandingskontrol Blumfeldt
- Vandingskontrol Cotech
- Vandingskontrol EVE
- Vandingskontrol Hunter
- Vandingskontrol Brandson
- Vandingskontrol GLORIA
- Vandingskontrol Toolcraft
- Vandingskontrol Claber
- Vandingskontrol Cocraft
- Vandingskontrol Nelson
- Vandingskontrol Weathermatic
- Vandingskontrol Rain
- Vandingskontrol DAB
- Vandingskontrol RAINBIRD
- Vandingskontrol Chapin
- Vandingskontrol Brendz
- Vandingskontrol MESTO
Nyeste Vandingskontrol Manualer
7 Oktober 2024
13 September 2024
6 September 2024
6 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024