7. Recommended Setup
Cleaning
Use a moist cloth to wipe down the pump housing. Allow to dry
thoroughly before storing in a dry location that is protected from bad
weather conditions.
Storage
If there is danger of frost, dismantle the device and accessories, clean
and store them in a place protected from frost.
Dismantle and store
1. Disconnect the device from the mains
supply.
2. Fully open any shut-off mechanisms
(spray nozzles, valves, etc.) in the
pressure line so that the air can escape
without obstruction.
3. Completely empty the pump by
unscrewing the water drain plug.
4. Dismantle the suction and pressure lines
from the device.
5. Store device in a frost-free room
(at least 5 °C).
WARNING! MAKE SURE THE PUMP IS DISCONNECTED
FROM ELECTRIC POWER SUPPLY BEFORE
PERFORMING MAINTENANCE PROCEDURES.
WARNING! THE INPUT HOSE OR PIPE SHOULD BE
LOW ENOUGH IN THE WATER TO ENSURE THAT IF
THE WATER LEVEL FALLS, THE PUMP WILL NOT RUN DRY.
ENSURE THAT THIS IS CHECKED WHEN IN OPERATION.
WARNING! MAKE SURE THAT THE DEVICE AND
CONNECTED ACCESSORIES ARE DEPRESSURIZED
BEFORE CARRYING OUT ANY WORK ON THE DEVICE.
Positioning the hose or pipe
Position the input hose or pipe so that it rises from the water drawing
source to the pump. Where possible, avoid positioning the input hose
or pipe higher than the pump, as this would delay the escape of air
bubbles from the input hose or pipe and impede the priming process
(see section for description on priming the pump)Priming the pump
• Thesuctionlineshouldbeasshortaspossible,sincetheconveying
capacity decreases as the length of the line increases.
Note: A leaking hose or pipe will draw in air and therefore not draw in
any water.
Note: A non-return valve is recommended so that the water does not
run off when the pump is shut off.
Note:Asuctionin-linelterwitha3000l/hourminowrate,and150to
250micronmeshmustbeusedtoprotectthepumpfromsand,dirtetc.
TheOzitoPAPF-001Pre-lterorequivalentisavailablefromBunnings
stores.
Note: During the initial set-up, please purge all air from the system via
the discharge outlet highest in the system.
INSTALLATION
Recommended set-up
Connection with tank base below water pump
Connection with tank base level with water pump
Connection with tank base above water pump
F EIRM BAS
SOLID STRUCTURE
0
1
2
3
4
5
6Bar
WATERTANK
NON-RETURN
VALVE
DISCHARGE
OUTLET
GATE
VALVE
SUCTION LINE
150mm 150mm
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
WATERTANK
GATE
VALVE
SUCTION LINE
150mm
F EIRM BAS
SOLID STRUCTURE
0
1
2
3
4
5
6Bar
DISCHARGE
OUTLET
150mm
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
0
1
2
3
4
5
6Bar
150mm 150mm
WATERTANK
GATE
VALVE
SUCTION LINE
SOLID STRUCTURE
DISCHARGE
OUTLET
F EIRM BAS
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
WARNING! TO ENSURE CORRECT PUMP OPERATION
IT IS ESSENTIAL THAT A SUCTION IN-LINE FILTER BE
USED FOR A CLEAN WATER SUPPLY.
MAINTENANCE


Produkt Specifikationer

Mærke: Ozito
Kategori: Pomp
Model: CPP-802

Har du brug for hjælp?

Hvis du har brug for hjælp til Ozito CPP-802 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pomp Ozito Manualer

Ozito

Ozito PTP-012A Manual

15 Oktober 2024
Ozito

Ozito CPP-802 Manual

10 August 2024
Ozito

Ozito PTP-425 Manual

8 August 2024
Ozito

Ozito PSDW-750 Manual

3 August 2024
Ozito

Ozito PFFP-65E Manual

30 Juli 2024
Ozito

Ozito PSA-001 Manual

25 Juli 2024

Pomp Manualer

Nyeste Pomp Manualer

AstralPool

AstralPool Eco Range Manual

15 December 2024
Gardenline

Gardenline GLRP 300 Manual

15 December 2024
MSW

MSW -MN34 Manual

15 Oktober 2024
MSW

MSW -MN34M Manual

15 Oktober 2024
MSW

MSW -AOP40S Manual

15 Oktober 2024
Nefit

Nefit VentiLine Manual

12 Oktober 2024
Liberty Pumps

Liberty Pumps 250 Manual

30 September 2024