PCE Instruments PCE-RE100P Manual


Læs nedenfor 📖 manual på dansk for PCE Instruments PCE-RE100P (10 sider) i kategorien Joystick. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/10
PCE-RE100P-EN-03-190211 1/10
PCE-RE100P Series Programmable Profile Controller
Thank you for choosing series programmable profile controller. PCE-RE100P
* 96x96mm sized.
* 3,5 inches TFT , graphic and 5 digit display.
* Selectable TC, RTD, NTC, R, mA, V or mV inputs.
* Input offset feature
* 32 point linearization for analog inputs.
* Selectable relay, SSR or analog outputs.
* Selectable , input proportional transmitter output(mA or V).
* 50ms sampling time.
* PID control.
* PID selftune.
* PID auto-tune.
Selftune automatic PID calculation or
manually enter PID parameters if known.
* Soft-Start feature.
* 24Vdc for sensor supply.
* 16 program and 8 step for profile control.
* Selectable Single Setpoint Mode or Profile Control Mode.
* Digital inputs for profile control.
* Security levels for menu and configuration pages.
* RS485 ModBus protocol communication feature.(optional)
* CE marked according to Europen Norms.
.
* In case of sensor failure manually , periodical or auto-periodical
control can be selected.
Analog Inputs
DIGITAL INPUTS (In order to use for profile control process)
OUTPUTS
ENVIRONMENTAL CONDITIONS
ELECTRICAL CHARACTERISTICS
HOUSING
Input Type
200,0 ... 1800,0 C°
-100,0 ..... 900,0 C°
-100,0 ..... 900,0 C°
-100,0 ... 1300,0 C°
-100,0 ..... 900,0 C°
-200,0 ... 1300,0 C°
0,0 ... 1700,0 C°
0,0 ... 1700,0 C°
-250,0 ..... 300,0 C°
-200,0 ..... 400,0 C°
-200,0 ..... 850,0 C°
-100,00 ... 160,00°C
-60,0 ..... 150,0 C°
5V or 30V pulse , Ri=100kΩ
% 0.1 or 2 C (3,6 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
Accuracy
+ undefined
+ purple
+ black
+ green
+ red
+ lilac
+ orange
+ orange
+ brown
+ red
Sensor current 250 Aµ
Cable ColorInput Resist.
- white
- white
- white
- white
- blue
- white
- white
- white
- white
- brown
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 0,5 C (1 F)± ± ° °
% 0.1 or 1 C (1.8 F)± ± ° °
% 0.1 or 1 C (1.8 F)± ± ° °
% 0.1 or 1 digit± ±
% 0.1 or 1 digit± ±
% 0.1 or 1.5 C (2.7 F)± ± ° °
Range
392,0 ... 3272,0 F°
-148,0 ... 1652,0 F°
-148,0 ... 1652,0 F°
-148,0 ... 2372,0 F°
-148,0 ... 1652,0 F°
-328,0 ... 2372,0 F°
32,0 ... 3092,0 F°
32,0 ... 3092,0 F°
-418,0 ..... 572,0 F°
-328,0 ..... 752,0 F°
-328,0 ... 1562,0 F°
-148,00 .. 320,00°F
-76,0 ..... 302,0 F°
RTD
NTC
V
mA
mV
Ω% 0.5 or 10± ± Ω
B (Pt30Rh-Pt6Rh)
E (NiCr-Con)
J (Fe-Con)
K (NiCr-Ni)
L (Fe-Con)
N (NiCrSi-NiSi)
R (Pt13Rh-Pt)
S (Pt10Rh-Pt)
T (Cu-Con)
U (Cu-Con)
Pt100
NTC
0 - 20mA
4 - 20mA
0 - 150mV
0 - 5V
1 - 5V
0 - 10V
0 - 550
0 - 10k
Ω
Ω
Control / Alarm 3
Alarm 1
Alarm 2
SSR
mA
V
Ambient/storage temp.
Max. Relative humidity
Rated pollution degree
Height
Supply
Power consumption
Wiring
EMC
Safety requirements
Housing type
Dimensions
Weight
Enclosure material
TC
Ri 50=Ω
Sensor current 250 Aµ
EN 60751
Standart
% 0.1 or 20 V± ± µ
% 0.2 or 0.1± ± Ω
EN 60584
EN 60584
DIN43710
DIN43710
250V AC, 2A . Selectable as NO+NC.10.000.000 switch without load and 200.000 switch under 250V AC 2A (resistive load)
250V AC, 2A . Selectable as NO+NC.10.000.000 switch without load and 200.000 switch under 250V AC 2A (resistive load)
250V AC, 2A . Selectable as NO.10.000.000 switch without load and 200.000 switch under 250V AC 2A (resistive load)
Max. 40mA , 0 - 12Volt , short-circuit protection.
0 - 20mA or 4 - 20mA , Max. load resistance is 750 .
Max. 30mA , 0 - 10Volt , short-circuit protection.
Ω
Ri 100k>Ω
Ri 100k>Ω
Ri 100k>Ω
Ri 100k>Ω
Ri 100k>Ω
Ri 100k>Ω
-32768 ... 32767
-3276,8 ... 3276,7
-327,68 ... 327,67
-32,768 ... 32,767
Do not use the device in locations subject to corrosive and flammable gases.
0 ... +50°C/-25 ... 70°C
Suitable for flush-panel mounting.
Relative humidity 80% for temperatures up to .31°C °C , decreasing linearly to 50% relative humidity at 40
G96xY96xD81mm
According to Front panel Rear EN 60529 : IP65 ,
panel : IP20
Approx. 400g.
Max. 2000m
Self extinguishing plastics.
While cleaning the device , solvents(thinner,gasoline,acid etc.) or corrosive materials must not be used.
2 0V AC, 50/60Hz90- 5
Max. 7 VA
2.5m screw-terminal
EN 61326-1: 201 3
EN 61010-1: 201 (0 Pollution degree 2 , overvoltage category ||)
°C
1230.6
1200.0
SV
SSR
A2
A1
A3
0%
Prog.No: Seg.No: 1 1
Prog.Remaining Time(min): 1:0
°C
PRESS SET TO START PROFILE CONTROLLER
PV
Read this document carefully before using this device. The guarantee will be expired by device damages if you don’t attend to the directions
in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages.
TM
Start-Stop Input
Previous Program Input
Next Program Input
Pause-Resume Input
200
175
150
125
100
75
50
25
0
PV-SV
min
2 4 6 8 10 12 14 16
Program 1 is running
PCE-RE-100P
PCE-RE-100P
PCE Teknik Cihazlar Paz. Tic. Ltd.Şti.
Halkalı Merkez Mah. Pehlivan Sok. No 6/C
34303 Küçükçekmece/ İstanbul
Türkiye


Produkt Specifikationer

Mærke: PCE Instruments
Kategori: Joystick
Model: PCE-RE100P

Har du brug for hjælp?

Hvis du har brug for hjælp til PCE Instruments PCE-RE100P stil et spørgsmål nedenfor, og andre brugere vil svare dig




Joystick PCE Instruments Manualer

Joystick Manualer

Nyeste Joystick Manualer

IVT

IVT MPPTplus+ 20A Manual

11 December 2024
COLBOR

COLBOR CTRL1 Manual

29 November 2024
Gioteck

Gioteck FR-1 (PS3) Manual

26 November 2024
Gioteck

Gioteck GC-1 (PS3) Manual

26 November 2024
Gioteck

Gioteck HF-2 (PS3) Manual

26 November 2024
Gioteck

Gioteck SC-1 (PS3) Manual

26 November 2024