DEFINITIONS - SAFETY GUIDELINES
indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
indicates a potentially haz ard ous situation which, if not avoided,
may result in minor or mod er ate injury.
NOTICE used without the safety alert symbol indicates potentially
hazardous situation which, if not avoided, result in may property damage.
To reduce the risk of injury, read the instruction manual.
GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions Failure to follow the
warnings and instructions may result in electric shock, fire and/or serious
injury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-
operated (cordless) power tool.
1) WORK AREA SAFETY
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or
fumes.
c) Keep children and bystanders away while operating a power tool. Distractions can
cause you to lose control.
2) ELECTRICAL SAFETY
a) Power tool plugs must match the outlet. Never modify the plug in any way. Do not
use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and
matching outlets will reduce risk of electric shock.
b) Avoid body contact with earthed or grounded surfaces such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is earthed
or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electric shock.
d) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged
or entangled cords increase the risk of electric shock.
e) When operating a power tool outdoors, use an extension cord suitable for outdoor
use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
f) If operating a power tool in a damp location is unavoidable, use a ground fault circuit
interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock.
3) PERSONAL SAFETY
a) Stay alert, watch what you are doing and use common sense when operating a
power tool. Do not use a power tool while you are tired or under the influence of
drugs, alcohol or medication. A moment of inattention while operating power tools may
result in serious personal injury.
b) Use personal protective equipment. Always wear eye protection. Protective equipment
such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for
appropriate conditions will reduce personal injuries.
c) Prevent unintentional starting. Ensure the switch is in the off position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or energizing power tools that have the
switch on invites accidents.
d) Remove any adjusting key or wrench before turning the power tool on. A wrench or
a key left attached to a rotating part of the power tool may result in personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This enables better
control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing and
gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in
moving parts.
g) If devices are provided for the connection of dust extraction and collection facilities,
ensure these are connected and properly used. Use of dust collection can reduce dust-
related hazards.
4) POWER TOOL USE AND CARE
a) Do not force the power tool. Use the correct power tool for your application. The
correct power tool will do the job better and safer at the rate for which it was designed.
b) Do not use the power tool if the switch does not turn it on and off. Any power tool that
cannot be controlled with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source and/or the battery pack from the power
tool before making any adjustments, changing accessories, or storing power tools.
Such preventive safety measures reduce the risk of starting the power tool accidentally.
d) Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power tool. Power
tools are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment or binding of moving parts, breakage
of parts and any other condition that may affect the power tool’s operation. If
damaged, have the power tool repaired before use. Many accidents are caused by
poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting
edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits, etc. in accordance with these
instructions, taking into account the working conditions and the work to be
performed. Use of the power tool for operations different from those intended could result in
a hazardous situation.
5) SERVICE
a) Have your power tool serviced by a qualified repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
ADDITIONAL SPECIFIC SAFETY RULES
• Hold power tools by insulated gripping surfaces, because the cutter may contact its
own cord. Cutting a “live” wire will make exposed metal parts of the tool “live” and shock
the operator.
• Use clamps or another practical way to secure and support the workpiece to a stable
platform. Holding the work by your hand or against the body leaves it unstable and may
lead to loss of control.
• DO NOT cut metal.
• Keep handles and gripping surfaces dry, clean, and free from oil and grease. This will
enable better control of the tool.
• Maintain firm grip with both hands on router to resist starting torque.
• Keep hands away from cutting area. Never reach under the workpiece for any reason.
Keep the router base firmly in contact with the workpiece when cutting. These precautions will
reduce the risk of personal injury.
• Never run the motor unit when it is not inserted in one of the router bases. The motor
is not designed to be handheld.
• Keep cutting pressure constant. Do not overload motor.
• Check to see that the cord will not snag or impede the routing operation.
• Use sharp cutters. Dull cutters may cause the router to swerve or stall under pressure.
• Be sure that the motor has stopped completely before you lay the router down. If the
cutter head is still spinning when the tool is laid down, it could cause injury or damage.
• Be sure that the router bit is clear of the workpiece before starting the motor. If the bit
is in contact with the workpiece when the motor starts it could make the router jump, causing
damage or injury.
• ALWAYS disconnect tool from power source before making adjustments or changing
bits.
• Keep hands clear of bit when motor is running to prevent personal injury.
• Never touch the bit immediately after use. It may be extremely hot.
• Provide clearance under workpiece for router bit when through-cutting.
• Tighten collet nut securely to prevent the bit from slipping.
• Never tighten collet nut without a bit.
• Do not use router bits with a diameter in excess of 1-3/8" (34.9mm) in this tool.
• Always use cutters with a shank diameter of 1/4" (6.4 mm) which corresponds to the size of the
collet in your tool.
• Always follow the bit manufacturer's speed recommendations as some bit designs
require specific speeds for safety or performance. If you are unsure of the proper speed
or are experiencing any type of problem, contact the bit manufacturer.
• Not recommended for use in a router table.
• Avoid climb-cutting (cutting in direction opposite that shown in Figure 12).
Climb-cutting increases the chance for loss of control resulting in possible injury.
When climb-cutting is required (backing around a corner), exercise extreme caution to maintain
control of router. Make smaller cuts and remove minimal material with each pass.
• An extension cord must have adequate wire size (AWG or American Wire Gauge) for
safety. The smaller the gauge number of the wire, the greater the capacity of the cable, that is
16 gauge has more capacity than 18 gauge. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. When using more than one extension to make up
the total length, be sure each individual extension contains at least the minimum wire size. The
following table shows the correct size to use depending on cord length and nameplate ampere
rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the
cord.
Minimum Gauge for Cord Sets
Ampere Rating
Volts Total Length of Cord in Feet (meters)
120V 25 (7.6) 50 (15.2) 100 (30.5) 150 (45.7)
240V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
More
Than
Not More
Than AWG
0 6 18 16 16 14
6 10 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not Recommended
ALWAYS use safety glasses. Everyday eyeglasses are NOT safety glasses.
Also use face or dust mask if cutting operation is dusty. ALWAYS WEAR CERTIFIED SAFETY
EQUIPMENT:
• ANSI Z87.1 eye protection (CAN/CSA Z94.3),
• ANSI S12.6 (S3.19) hearing protection,
• NIOSH/OSHA/MSHA respiratory protection.
Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known to the State of California to cause cancer, birth
defects or other reproductive harm. Some examples of these chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement and other masonry products, and
• arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well ventilated area, and work with approved safety
equipment, such as those dust masks that are specially designed to filter out microscopic particles.
• Avoid prolonged contact with dust from power sanding, sawing, grinding, drilling, and
other construction activities. Wear protective clothing and wash exposed areas with
soap and water. Allowing dust to get into your mouth, eyes, or lay on the skin may promote
absorption of harmful chemicals.
Use of this tool can generate and/or disburse dust, which may cause
serious and permanent respiratory or other injury. Always use NIOSH/OSHA approved
respiratory protection appropriate for the dust exposure. Direct particles away from face
and body.
Always wear proper personal hearing protection that conforms to ANSI
S12.6 (S3.19) during use. Under some conditions and duration of use, noise from this product
may contribute to hearing loss.
• The label on your tool may include the following symbols. The symbols and their definitions are
as follows:
V .....................volts A .........................amperes
Hz ...................hertz W ........................watts
min .................minutes or AC .............alternating current
or DC .....direct current or AC/DC......alternating or direct current
...................Class I Construction no .......................no load speed
...
...
...
.......
....
....
........
....
....
.......
...
...
.......
....
....
........
....
....
.....
.
.
.(grounded) n .........................rated speed
...................Class II Construction .......................earthing terminal
(double insulated) ........................safety alert symbol
…/min ............per minute BPM ...................beats per minute
IPM .................impacts per minute RPM ...................revolutions per minute
SPM ...............strokes per minute sfpm ...................surface feet per minute
OPM ................orbits per minute
SAVE THESE INSTRUCTIONS
MOTOR
Be sure your power supply agrees with nameplate marking. 120 Volts AC means your tool will
operate on alternating current. As little as 10% lower voltage can cause loss of power and can
result in overheating. All PORTER-CABLE tools are factory-tested; if this tool does not operate,
check the power supply.
To reduce the risk of injury, turn unit off and disconnect it from power
source before installing and removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
COMPONENTS (FIG. 1–11)
A. Quick release tabs R. Centering tool
B. Depth adjustment ring S. Collet nut
C. On(l)/off (o) switch T. Vacuum attachment (fixed base)
D. Spindle lock button U. Screws (vacuum attachment)
E. Guide pin groove V. Edge guide slot (plunge base)
F. Micro adjustment scale W. Router bit
G. Locking lever X. Motor unit
H. Edge guide slot (fixed base) Y. Motor stop
I. Subbase (sold separately) Z. Thumb screw
J. Vacuum attachment AA. Knurled knob
(For use with plunge base) BB. Depth adjustment scale
K. Holes for premium edge guide CC. Zero adjuster tab
(sold separately) DD. Sub-base screws
L. Turret stop EE. Edge guide screws
M. Depth adjustment rod FF. Tab (vacuum attachment)
N. Plunge lock lever GG. Snap tab (vacuum attachment)
O. Edge guide HH. Plastic washer (vacuum attachment)
P. Guide pins II. Thumb screw (vacuum attachment)
Q. Locking lever adjustment screw
OPERATION
To reduce the risk of injury, turn unit off and disconnect it from power
source before installing and removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
NOTICE Do not use router bits with a diameter in excess of 1-3/8" (34.9mm) in
this tool.
CONNECTING TO POWER SOURCE
Before connecting tool to power source, check to see that the switch is in
the "OFF" position. Also, check the power circuit to see that it is the same as that shown on
specification plate of the tool.
STARTING AND STOPPING THE MOTOR (FIG. 1)
Before starting the tool, clear the work area of all foreign objects. Also keep firm
grip on tool to resist starting torque.
To avoid personal injury and/or damage to finished work, always allow the power
unit to come to a COMPLETE STOP before putting the tool down.
To turn unit on, depress the side of the dust-protected switch (C) that reads “ON” and corresponds to
the symbol “I.” To turn the unit off, depress the side of the switch that reads “OFF” and corresponds
with the symbol “O.”
MOTOR QUICK RELEASE (FIG. 2)
To reduce the risk of injury, turn unit off and disconnect it from power
source before installing and removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
1. Open the locking lever (G) on the base.
2. Grasp the motor unit (X) with one hand, depressing both quick release tabs (A).
3. With the other hand, grasp the base and pull motor from the base.
BIT INSTALLATION AND REMOVAL (FIG. 3)
To reduce the risk of injury, turn unit off and disconnect it from power
source before installing and removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
TO INSTALL THE BIT
1. Remove the motor unit from the base unit, see (if needed).Motor Quick Release
2. Clean and insert the round shank of the desired router bit into the loosened collet as far as it
will go and then pull it out about 1/16" (1.6 mm).
Instruction manual
Manuel d'instructions
Manual de'instrucciones
450
Part No. N336759 FEB14 Copyright © 2010, 2014 PORTER-CABLE
www.portercable.com
INSTRUCTIVO DE OPERACIÓN, CENTROS
DE SERVICIO Y PÓLIZA DE GARANTÍA.
LÉASE ESTE INSTRUCTIVO
ANTES DE USAR EL PRODUCTO.
COMPACT ROUTER
TOUPIE COMPACTE
REBAJADORA
COMPACTA
The following are PORTER-CABLE trademarks for one or more power tools and accessories: a gray and black color
scheme; a “four point star” design; and three contrasting/outlined longitudinal stripes.
Produkt Specifikationer
Mærke: | Porter-Cable |
Kategori: | Router |
Model: | 450 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Porter-Cable 450 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Router Porter-Cable Manualer
14 August 2024
4 August 2024
3 August 2024
25 Juli 2024
24 Juli 2024
1 November 2023
9 August 2023
25 Maj 2023
24 November 2022
Router Manualer
- Router QNAP
- Router Nilox
- Router Bosch
- Router Acer
- Router TCL
- Router Aruba
- Router Siemens
- Router Netis
- Router Samsung
- Router Metabo
- Router DeWalt
- Router TP-Link
- Router Silverline
- Router AT&T
- Router Apple
- Router Google
- Router Technaxx
- Router HP
- Router Makita
- Router D-Link
- Router Motorola
- Router Roland
- Router Asus
- Router Gigabyte
- Router Güde
- Router AVM
- Router Planet
- Router Hama
- Router Thomson
- Router Milwaukee
- Router Nokia
- Router Belkin
- Router Edimax
- Router Black Box
- Router Clas Ohlson
- Router Strong
- Router TRENDnet
- Router Trust
- Router Topcom
- Router Black And Decker
- Router Einhell
- Router Hikoki
- Router Hitachi
- Router Buffalo
- Router Medion
- Router Sweex
- Router Vivanco
- Router Linksys
- Router Festool
- Router Cisco
- Router EZVIZ
- Router Huawei
- Router König
- Router Technicolor
- Router Gembird
- Router Netgear
- Router EnVivo
- Router Totolink
- Router Nest
- Router Vtech
- Router BenQ
- Router Powerplus
- Router Alcatel
- Router Western Digital
- Router Anker
- Router Digitus
- Router Zebra
- Router Thrustmaster
- Router Xiaomi
- Router Techly
- Router Dell
- Router Schneider
- Router Kopul
- Router MSI
- Router Nexxt
- Router APC
- Router Foscam
- Router Kathrein
- Router Kyocera
- Router Sonos
- Router AJA
- Router LevelOne
- Router Mercusys
- Router Zoom
- Router JUNG
- Router ZyXEL
- Router Sagem
- Router Tenda
- Router Vodafone
- Router Synology
- Router Hikvision
- Router Ubiquiti Networks
- Router Cotech
- Router EnGenius
- Router Devolo
- Router Patton
- Router Renkforce
- Router Kraun
- Router Manhattan
- Router ZTE
- Router Mikrotik
- Router Aztech
- Router LogiLink
- Router Alfa
- Router Eminent
- Router Kramer
- Router BT
- Router Hercules
- Router MuxLab
- Router Phicomm
- Router Telstra
- Router Upvel
- Router Arris
- Router Milan
- Router Xantech
- Router Mercku
- Router Kasda
- Router Iogear
- Router Digi
- Router ATen
- Router Smart-AVI
- Router Dahua Technology
- Router StarTech.com
- Router Draytek
- Router Conceptronic
- Router Teltonika
- Router Toolcraft
- Router SPL
- Router Lindy
- Router Kogan
- Router AVMATRIX
- Router Barco
- Router Peak
- Router Lumantek
- Router Lancom
- Router FSR
- Router RAVPower
- Router Sitecom
- Router Intellinet
- Router Holzmann
- Router Ocean Matrix
- Router Comprehensive
- Router Intelix
- Router Digitalinx
- Router Alfatron
- Router Media-Tech
- Router BZBGear
- Router Key Digital
- Router KanexPro
- Router Gefen
- Router RGBlink
- Router Moxa
- Router Bea-fon
- Router Blustream
- Router WyreStorm
- Router Allnet
- Router Allied Telesis
- Router Airlive
- Router Actiontec
- Router Proximus
- Router KPN
- Router ICIDU
- Router Verizon
- Router Billion
- Router T-Mobile
- Router Hawking Technologies
- Router Beafon
- Router Zolid
- Router Sagemcom
- Router SIIG
- Router Eero
- Router Advantech
- Router Approx
- Router Arcadyan
- Router Digiconnect
- Router Ubee
- Router SMC
- Router Tele 2
- Router Cambium Networks
- Router CradlePoint
- Router ModeCom
- Router Extreme Networks
- Router Davolink
- Router Sixnet
- Router 7inova
- Router AVPro Edge
- Router Cudy
- Router F-Secure
- Router Mach Power
- Router Rosewill
- Router Digicom
- Router Sabrent
- Router On Networks
- Router Atlona
- Router PENTAGRAM
- Router Leoxsys
- Router Readynet
- Router OneAccess
- Router Accelerated
- Router Nexaira
- Router Hamlet
- Router T-com
- Router A-NeuVideo
- Router Amped Wireless
- Router 3Com
- Router I-Tec
- Router Avenview
- Router Ruckus Wireless
- Router Dovado
- Router StarIink
- Router EXSYS
- Router NetComm
- Router Juniper
- Router Comtrend
- Router Premiertek
- Router GL.iNet
- Router Shinybow
- Router Edgewater
- Router Atlantis Land
- Router Lantronix
- Router Keenetic
- Router Starlink
- Router Keewifi
- Router Milesight
- Router PulseAudio
- Router Predator
- Router Luxul
- Router Silentwind
- Router Keezel
- Router United Telecom
- Router Wisetiger
- Router Zurn
Nyeste Router Manualer
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024