Radiant TH52Z Manual


Læs nedenfor 📖 manual på dansk for Radiant TH52Z (5 sider) i kategorien Termometer. Denne guide var nyttig for 21 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/5
Before the measurement, please make sure the selected
button accords with the measured position.
TH52Z Multi-function Infrared Thermometer
Functions
Real Time Clock
The real time clock will be recorded with the memory function and help you to recognize each
measurement result. (It includes the 12/24 Format_Hour_Minutes_Date.)
Please see the “Real time clock setting” section to learn how to setup the time in the first use.
Room Temperature
Suitable ambient temperature is important for the baby and patient, the thermometer always help you
recognize the room temperature.
Setting “Real time clock” first to enable this function. After power off, room temperature will be shown
on the screen with icon.
Please see the “Use of the thermometer” section to learn how to get the correct room temperature.
Forehead / Ear
Temperature
The thermometer has been designed for practical use. It’s not meant to replace a visit to the doctor.
Please also remember to compare the measurement result to your regular body temperature. Please
consult with doctor if you have health concerns.
Please see the “Use of the thermometer” section to learn how to measure the body temperature.
Scan Mode
The Scan mode shows the actual, unadjusted surface temperatures, which is different from the body
temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for
example the baby’s milk.
Please see the “Use of the thermometer” section to learn how to measure the object temperature.
Stopwatch The thermometer built the stopwatch function to help you to monitor the heartbeat
since heartbeat is one
of the healthy indexes for people.
Please see the “Use of the Stopwatch” section to learn how to measure the heartbeat result.
Fever Alarm If thermometer detects a body temperature > 37.5°C, there will be a long beep sound followed by three
short beep sound to warn the user for potential fever.
Zone Indicator Under ear or forehead mode, if thermometer detects a body temperature< 37.5°C, there will be " Green"
light signal; if temperature > = 37.5°C and < 38.0°C, there will be" Yellow" light signal; if temperature
> =38.0°C, there will be" Red" light signal.
Memory Locations There are total 9 sets memories for body measurement. Each memory also records the measurement
date/time/mode icon and site location..
When in power on, Press the “ON/MEM” button to see the temperature stored with icon.
°C / °F Switch In “power off” mode (The LCD only shows the date, time and room temperature). Press and hold the
“FOREHEAD” button, then immediately press and release the “ON/MEM”
button. After 3 seconds, icon
“°C” will be switched to icon “°F”. (You may use the same way to switch back to “°C”)
Real time clock setting
1. Power on: Press the “ON/MEM” button. The thermometer is ready for use after hearing two beep sounds.
2. Press and hold the “ON/MEM” button for 5sec. When you see the Set icon starts flashing, it indicates that you are in the setting screen.(see the following figure.)
3. Press the “FOREHEAD” button to make the “24” icon flash. This indicates that you are in the 12/24-hour setting screen. Press the “FOREHEAD” button to set
12/24-hour Format from “24”(24-hour) to “12”(12-hour).
4. Press “ON/MEM” button to move the flashing in the sequence shown below to select our settings:
hourminutesyearmonthdayleave the setting screen.
5. While the hour, minutes, year, month, day setting is flashing, use “FOREHEAD” button to change it.
Use of the thermometer
1. Always make sure the probe is clean, and without damage.
2. Power on: Press “ON/MEM” button.(see figure 1)
3. Mode selection:
3.1 Ear mode :Press the “Ear” button, you can get the body temperature by ear measurement after
hearing two beep sounds. (see figure 1)
Specifications Temperature measurement range:
Forehead / Ear mode: 34~42.2°C (93.2~108°F), Scan mode: -22~80°C (-7.6~176°F)
Operating temperature range: 10~40°C (50~104°F)
Storage temperature range: It should be stored at room temperature between -20~+50°C,
RH85%
Transportation temperature shall be less than 70°C, RH95%
Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part
5:Performance of infra-red ear thermometers(with maximum device),
IEC/EN60601-1-2(EMC),IEC/EN60601-1(Safety) standards.
Accuracy:
For ear mode: +/-0.2°C (0.4°F) during 35.5~42°C (95.9~107.6°F),
+/-0.3°C (0.5°F) for other range.
For forehead mode: +/-0.2°C (0.4°F) during 36~39°C (96.8~102°F),
+/-0.3°C (0.5°F) for other range.
For scan mode: +/-0.3°C (0.5°F) during 22~42.2°C (71.6~108°F),
others +/-4% or +/-2°C (4°F) whichever is greater.
Fever alarm & Memory locations under “Ear/Forehead mode” (with each measurement
date/time/mode icon)
3 color LED Fever Indicator
Real time clock, °C / °F Switch mode
Battery: one lithium cell battery (CR2032 *1pcs)
This thermometer converts the ear/forehead temperature to display its “oral equivalent.”
There is no gender and age limitation for using infrared thermometer.
This is not an AP or APG product.
Figure 1 Figure2 Figure 3 Figure
4


Produkt Specifikationer

Mærke: Radiant
Kategori: Termometer
Model: TH52Z

Har du brug for hjælp?

Hvis du har brug for hjælp til Radiant TH52Z stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer Radiant Manualer

Radiant

Radiant TH52Z Manual

26 August 2024

Termometer Manualer

Nyeste Termometer Manualer

Philips

Philips Avent SCH401 Manual

24 December 2024
TFA

TFA 12.1004 Manual

21 December 2024
Owon

Owon TI219 Manual

21 December 2024
TFA

TFA 30.1000 Manual

17 December 2024
TFA

TFA 14.1503 Manual

17 December 2024
TFA

TFA 15.2010 Manual

17 December 2024
TFA

TFA 30.3053.IT Manual

16 December 2024
Optex

Optex PT-7LD Manual

16 December 2024
Optex

Optex PT-U80 Manual

16 December 2024