Ronda 5021D Manual

Ronda Horloge 5021D

Læs nedenfor 📖 manual på dansk for Ronda 5021D (1 sider) i kategorien Horloge. Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
Cal. 5030.D Cal. 5021.D
English
User’s Manual
65,5% = 40mm Druchmesser
10
20
30
12
2
4
6
8
10
15
60
30
45
23
10
20
30
15
60
30
45
23
1
0
20
30
12
2
4
6
8
10
15
60
30
45
23
Description of the display and control buttons
Display elements
Second hand
Minute hand
Hour hand
Centre stop-second
Minute counter
Hour counter
Date
Control buttons
Push button A
Crown
Push button B
1
0
20
30
12
2
4
6
8
1
0
15
60
30
45
23
10
20
30
12
2
4
6
8
1
0
15
60
30
45
23
Chronograph: Basic function
(Start / Stop / Reset)
Example:
Start:
Press push-button
A
.
Stop:
to stop the timing, press push-
button A once more and read the three
chronograph hands:
1h
/
20min
/
10 sec.
Zero positioning:
Press push-button
B
.
(The three chronograph hands will be reset
to their zero positions).
Push-button A
Push-button B
Minute counter
Hour counter
1
0
20
30
12
2
4
6
8
1
0
15
60
30
45
23
10
20
30
12
2
4
6
8
1
0
15
60
30
45
23
Chronograph:
Accumulated timing
Example:
Start:
(start timing)
Stop:
(e.g.
15
min
5
sec following
)
Restart:
(timing is resumed)
*
Stop:
(e.g.
13
min
5
sec following
)
=28 min 10 sec
(
The accumulated measured time is shown
)
Reset:
The three chronograph hands are returned
to their zero positions.
Push-button A
Push-button B
Please note:
* Following
, the accumulation of the
timing can be continued by pressing
push-
button A
(Restart / Stop, Restart / Stop, …)
Minute counter
Hour counter
1
0
20
30
12
2
4
6
8
1
0
15
60
30
45
23
10
20
30
12
2
4
6
8
1
0
15
60
30
45
23
Chronograph:
Intermediate or interval timing
Example:
Start:
(start timing)
Display interval:
e.g.
10 minutes 10 seconds
(timing
continues in the background)
Making up the measured time:
(the 3 chronograph hands are quickly
advanced to the ongoing measured time).
Stop:
(Final time is displayed)
Reset:
The 3 chronograph hands are returned to
their zero position
Push-button A
Push-button B
Push-button B
Please note:
* Following
, further intervals or inter-
mediates can be displayed by pressing
push-button B
(display interval / make up
measured time, ...)
*
Minute counter
Hour counter
1
0
20
30
12
2
4
6
8
1
0
15
60
30
45
I II III
23
10
20
30
12
2
4
6
8
1
0
15
60
30
45
23
III
Adjusting the chronograph
hands to zero position
Example:
One or several chronograph hands are not in
their correct zero positions and have to be
adjusted (e.g. following a battery change).
Pull out the crown to position
III
(all 3
chronograph hands are in their correct or
incorrect zero position).
Keep push-buttons
A and B
depressed
simultaneously
for at least 2 seconds
(the centre stop-second rotates by
360°
corrective mode is activated).
Center
stop-second
Push-button A
Push-button B
Minute counter
Hour counter
Adjusting the centre stop second
A
A
1 x short
long
Single step
Continuous
Adjusting the next hand B
Adjusting the next hand B
Returning the crown to position
I
Termination of the chronograph hands adjustment
(can be carried out at any time).
III
I II
A
B
A
A
B
A
A
1 x short
long
Single step
Continuous
A
A
1 x short
long
Single step
Continuous
Adjusting the hour counter hand (position 6h)
Adjusting the minute counter hand (position 9h)
I II III
10
20
30
1
2
2
4
6
8
10
15
60
30
45
23
I II III
10
20
30
12
2
4
6
8
1
0
15
60
30
45
23
Setting the time
*Pull out the crown to position
III
(the watch stops).
Turn the crown until you reach the correct
time
8:45
.
*Push the crown back into position
I.
Please note:
* In order to set the time to the exact second,
must be pulled out when the second hand
is in position «60» (I).
Once the hour and minute hands have been
set,
must be pushed back into position I at
the exact second.
Second hand
 
I II
1
0
20
30
12
2
4
6
8
1
0
15
60
30
45
31
I II
10
20
30
12
2
4
6
8
1
0
15
60
30
45
1
Setting the date (quick mode)
Pull out the crown to position
II
(the watch
continues to run).
Turn the crown until the correct
date appears.
Push the crown back into position
I
.
1
Please note:
During the date changing phase between
9 PM and 12 PM; the date must be set to the
date of the following day.
 
I II
10
20
30
1
2
2
4
6
8
10
15
60
30
45
17
I II
10
20
30
12
2
4
6
8
10
15
60
30
45
3
Setting the date/time
following a battery change
Example:
– Date / time on the watch: / 1:25 AM
– Present date / time: / 8:30 PM
Pull out the crown to position
II
(the watch continues to run).
Turn the crown until yesterday’s date
appears .
3
17
4
Crown
Date
I II III
10
20
30
1
2
2
4
6
8
10
15
60
30
45
3
I II III
10
20
30
12
2
4
6
8
10
15
60
30
45
4
**Pull out the crown to position
III
(the watch stops).
**Turn the crown until the correct date
appears.
**Continue to turn the crown until the
correct time 8:30 PM appears.
**Push the crown back into position
I
.
4
Please note:
**To set your watch to the exact second,
please refer to the chapter entitled «setting
the time».
**Please observe the AM/PM clock rhythm.
Second hand
RONDA is a supplier of watch movements including their operating instructions.
Please refer to the watch retailer, service centre or manufacturer, should you have any
questions regarding the watch. All relevant contact information can be found in your
sales and/or guarantee documents.
www.ronda.ch
05/ 2012
Battery type: 395 (diameter 9.5mm x 2.6mm / SR 927 SW)
Accuracy: +20 / -10 seconds per month


Produkt Specifikationer

Mærke: Ronda
Kategori: Horloge
Model: 5021D

Har du brug for hjælp?

Hvis du har brug for hjælp til Ronda 5021D stil et spørgsmål nedenfor, og andre brugere vil svare dig




Horloge Ronda Manualer

Ronda

Ronda 515.24 Manual

26 August 2024
Ronda

Ronda 510 Manual

26 August 2024
Ronda

Ronda 514 Manual

26 August 2024
Ronda

Ronda 8040N Manual

26 August 2024
Ronda

Ronda 706 Manual

26 August 2024
Ronda

Ronda 516 Manual

26 August 2024
Ronda

Ronda 5021D Manual

26 August 2024
Ronda

Ronda 517 Manual

26 August 2024

Horloge Manualer

Nyeste Horloge Manualer