SANDPIPER PortaPump SPA 1-1/2-E Manual
Læs nedenfor 📖 manual på dansk for SANDPIPER PortaPump SPA 1-1/2-E (5 sider) i kategorien Pomp. Denne guide var nyttig for 19 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/5
spa105dl3sm Model SPA1½-E and SPA40-E Design Level 3 Page 1
WARREN RUPP, INC., A unit of IDEX Corporation • 800 N. Main Street • Manseld, OH 44902 USA • (419) 524-8388 Fax (419) 522-7867
OPERATING INSTRUCTIONS
THE PUMP: This pump is a totally enclosed, submersible dewatering unit. It is
powered by a 1/3 HP, 12 volt DC 30 AMP motor. Battery clips on the power cord allow
easy connection to any 12 volt vehicle battery.
SWITCHING: The on-off switch is located on the power cord.
CONNECTING TO BATTERY: When connecting the clips to a battery, arcing is
eliminated by keeping the on-off switch in the “off” position. Connect the red battery
clamp to the positive (+) battery terminal. Connect the black battery clamp to ground:
preferably on the vehicle’s engine to a solid, metallic, stationary point. The connection
should be at least 18 inches (480mm) from the battery.
HOSE: Since the pump develops relatively low pressure, it is recommended that
non-collapsible hose be used for maximum pumping rates.
HOISTING & LOWERING: Attach a line to the metal handle on the top of the
pump for hoisting or lowering the unit. Do not use power cable for handling unit.
TO OPERATE: Lower unit into liquid to be pumped and activate switch. Pump
can be run for a few minutes without liquid, however, do not run completely dry for
extended periods. Damage to shaft seal may result.
RUNNING TIME: This unit draws about 30 amperes and can be operated
about 1hour on a fully charged 55 AMP-hour battery and still permit starting of
vehicle under normal conditions. Caution should be used when running time
exceeds 30 or 40 minutes without engine running to recharge battery, particularly
in cold weather when battery efciency is lowered. Battery size (AMP-hour rating)
and the use of other accessories such as lights and radios, etc., must be taken into
consideration for practical running periods without engine running.
OVERLOAD PROTECTION is provided by means of a 40 amp automatic reset
circuit breaker, located under top cover.
SERVICE AND OPERATING MANUAL
PortaPump® Model SPA 1½-E
Model SPA40-E
Design Level 3
Turn o before connecting ff
ba ery clamps to battery. tt
Arcing could result.
DANGER
IMPORTANT
Read these safety warning s
and instructions in thi s
manu plal com etely, before
installation and start-up of the pump. It is
the responsibility of the purchaser to retain
this manual for reference. Failure to comply
with the recommendations stated in thi s
manual will damage the pump, and voi d
factory warranty.
DANGER
DANGER: Not for use with f sluid
that have a flash point below 100°
F ](38° C) [examples: gasoline, alcohol.
Sparking could result in death.
Should unit not operate ,
always check freeness
of grotation of impeller by insertin
scre river thr e basewd ough hol in
plate into slot in end of shaft.
IMPORTANT
Produkt Specifikationer
Mærke: | SANDPIPER |
Kategori: | Pomp |
Model: | PortaPump SPA 1-1/2-E |
Har du brug for hjælp?
Hvis du har brug for hjælp til SANDPIPER PortaPump SPA 1-1/2-E stil et spørgsmål nedenfor, og andre brugere vil svare dig
Pomp SANDPIPER Manualer
2 September 2024
2 September 2024
Pomp Manualer
- Pomp Scheppach
- Pomp SilverCrest
- Pomp Ozito
- Pomp Siemens
- Pomp Metabo
- Pomp Husqvarna
- Pomp RYOBI
- Pomp Gardena
- Pomp AL-KO
- Pomp Zipper
- Pomp Technaxx
- Pomp Makita
- Pomp Worx
- Pomp SKS
- Pomp Güde
- Pomp Eheim
- Pomp Biltema
- Pomp Bartscher
- Pomp Vonroc
- Pomp Hyundai
- Pomp Milwaukee
- Pomp Crivit
- Pomp Outwell
- Pomp Eurom
- Pomp Einhell
- Pomp Quigg
- Pomp Alpha Tools
- Pomp Osram
- Pomp Melinera
- Pomp FIAP
- Pomp Neptun
- Pomp Oase
- Pomp Pontec
- Pomp EvoHeat
- Pomp Ultimate Speed
- Pomp Vaillant
- Pomp Powerfix
- Pomp Hayward
- Pomp Hozelock
- Pomp Kärcher
- Pomp Michelin
- Pomp Coleman
- Pomp Danfoss
- Pomp Powerplus
- Pomp Enermax
- Pomp Westfalia
- Pomp Nibe
- Pomp Sanibroyeur
- Pomp Fieldmann
- Pomp Velda
- Pomp Ferroli
- Pomp Zodiac
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Gre
- Pomp Fluke
- Pomp Sun Joe
- Pomp Waldbeck
- Pomp Lezyne
- Pomp Lavorwash
- Pomp Generac
- Pomp ESPA
- Pomp Panduit
- Pomp Jabsco
- Pomp Polaris
- Pomp Pedrollo
- Pomp JANDY
- Pomp Toolcraft
- Pomp Simpson
- Pomp Fuxtec
- Pomp AstralPool
- Pomp Whale
- Pomp T.I.P.
- Pomp Topeak
- Pomp Nefit
- Pomp Sicce
- Pomp Tacklife
- Pomp Bulex
- Pomp For_Q
- Pomp Abac
- Pomp Cannondale
- Pomp Maruyama
- Pomp Batavia
- Pomp Gardenline
- Pomp Grundfos
- Pomp Perlick
- Pomp DAB
- Pomp Comet
- Pomp Vivaria
- Pomp Plantiflor
- Pomp Verto
- Pomp Wetelux
- Pomp Germania
- Pomp Anova
- Pomp Little Giant
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp Rule
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp MSW
- Pomp OKAY
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zéfal
- Pomp Zehnder Pumpen
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nyeste Pomp Manualer
22 December 2024
15 December 2024
15 December 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
12 Oktober 2024
6 Oktober 2024