Smartwares FGA-13051 Manual


Læs nedenfor 📖 manual på dansk for Smartwares FGA-13051 (6 sider) i kategorien Gasdetektor. Denne guide var nyttig for 39 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
1
2
3
= Alarm
= Fault
= Power
Image 1:
TEST FGA-1305
1 2 3
min. 150cm
above the floor
min. 150cm from
the appliance
TEST FGA-1305
min. 30cm from the ceiling
Image 2:
Wall mount
Image 4: Back side - mounting plate
Image 3: Back side - CO detector
AA 1,5V
1,5V AA
1,5V AA
Image 5: Attaching alarm to mounting plate
SAFETY PIN
1
ENInstruction manual
GENERAL INFORMATION
Thank you for purchasing this Smartwares carbon monoxide alarm!
Please read these instructions carefully before using the carbon
monoxide alarm. Retain this information in a safe and easily
accessible place for future use and maintenance. If you have any
questions or if you are looking for additional information about your
carbon monoxide alarm or prevention of carbon monoxide poisoning,
please visit our website www.smartwares.eu.
Make/model number: FGA-1305
Battery powered carbon monoxide alarm with anDescription:
electrochemical sensor with a lifetime of 5 years under normal
circumstances. This apparatus contains 3 x AA 1.5VDC LR6
Alkaline batteries with a lifetime of 5 years and is supplied with a
wall plug and screw.
Carbon monoxide alarm device intended to alertFunction:
persons in case of carbon monoxide to give them time to react
properly to the danger.
Carbon monoxide alarm for buildings withScope of application:
residential function.
IMPORTANT:
The alarm is designed in order to detect carbonCaution:
monoxide; it cannot prevent a leakage!
The carbon monoxide alarm may not be painted orCaution:
covered because this may cause loss of functionality.
The carbon monoxide alarm must be replaced no laterWarning:
than 10 years after production date.
When the detector has been working for ten years, the product
cannot be used anymore. Mark the replacement date in your
calendar or register for free at www.smartreminder.eu
LED indicators (see image 1)
1. Alarm
2. Fault
3. Power
WHAT IS CARBON MONOXIDE
Carbon Monoxide (CO) is an insidious poison that is released when
fuels are burnt. It is a colorless, odorless, tasteless gas and
therefore very difficult to detect with the human senses. CO kills
hundreds of people each year and injures many more. It binds to the
hemoglobin in the blood and reduces the amount of oxygen being
circulated in the body. In high concentrations, CO can kill in minutes.
CO is produced by the incomplete combustion of fuels such as
wood, charcoal, coal, heating oil, paraffin, petrol, natural gas,
propane, butane etc. :Examples of CO sources
Running engine in garage Gas appliances
Oil and Gas furnaces Portable generators
Wood stoves Gas or kerosene heaters
Barbecues Clogged chimneys
Wood and gas fireplaces Heating boiler
SYMPTOMS OF CO POISONING
The following symptoms may be related to CO poisoning (ppm =
parts per million/ 1:1000.000):
35 ppm The maximum allowable concentration for continuous
exposure for healthy adults in any 8 hour period.
200 ppm Slight headaches, fatigue, nausea after 2-3 hours.
400 ppm Frontal headaches within 1-2 hours, life threatening
after 3 hours.
800 ppm Dizziness, nausea and convulsions within 45 minutes.
Unconsciousness within 2 hours. Death within 3 hours.
1600 ppm Headache, dizziness and nausea within 20 minutes.
Death within 1 hour.
6400 ppm Headache, dizziness and nausea within 1-2 minutes.
Warning: the apparatus may not prevent the chronic effects of CO
exposure or protect individuals who are at specific risk, always pay
attention to the symptoms of carbon monoxide poisoning.
LOCATING THE CO ALARM
The Carbon Monoxide alarm is designed to detect the toxic CO
fumes that result from incomplete combustion, such as those emitted
from appliances, furnaces, fireplace and auto exhaust. If your
dwelling is on a single story, for minimum protection you should fit an
alarm in the bedrooms or in the hallway of sleeping areas. Place it
as near to the sleeping areas as possible and ensure the alarm is
audible when the bedrooms are occupied. If your dwelling is multi-
story, for minimum protection place at least one alarm on each floor.
NOTE: For maximum protection an alarm should be fitted in or near
every room that contains a fuel-burning appliance such as any gas
fires, central heating boilers, room heaters, water heaters, cookers,
grills, etc.
CAUTION: This alarm will only indicate the presence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be present
in other areas.
Warning: a carbon monoxide alarm does not function as a
replacement for a smoke or gas detector.
POSITIONING THE CO ALARM (see image 2)
Carbon monoxide (CO) has a similar density to warm air and, to
ensure that the most effective use is made of the detector, it should
be fitted as follows: In rooms with a fuel-burning appliance CO will
mix with the warm air and rise up. Place the CO alarm on a the wall,
30-80 cm below the ceiling but above the top of any doors or
windows at a horizontal distance of minimum 150cm from the
possible source of CO. It is also optional to place the alarm on a
ceiling.
In rooms where people sleep or are present for a longer period of
time (bedroom, living room) place the CO alarm at breathing height.
For more information and examples see www.smartwares.eu.
Areas to be avoided include the following:
Situations where the temperature may fall below 0°C or rise above
45°C
Any area where high levels of dusty, dirty or greasy emissions
could contaminate or clog the sensor.
Behind drapes or furniture.
In the path of air discharged from a furnace / air conditioning vent
or ceiling fan.
Outside the building.
Directly above a sink or cooker.
In areas where there are a lot of lampback and dust which will
block up the sensor.
In too damp areas.
CAUTION: This carbon monoxide alarm is designed for indoor use
only. Do not expose to rain or moisture. It will not protect against the
risk of carbon monoxide poisoning when the battery has drained. Do
not open or tamper with the alarm as this could cause malfunction
and risk of electric shock.
INSTALLING THE CO ALARM
Before mounting your CO alarm, you have to attach the rating label
in your own language to the detector.
In order to ensure the product is correctly installed and used, it
should be installed strictly according to this user manual or be
installed by qualified professional personnel. This CO alarm is
powered by a battery and requires no additional wiring. Make sure
the alarm can be heard from all sleeping areas or place several
alarms.
Wall mount installation:
Having established the mounting location ensure that there is no
electrical wiring or pipe work in the area adjacent to the mounting
surface.
Mark the mounting hole location, drill a ø 6mm and 40 mm depth
hole in the marked position and insert the wall plug.
Before screwing the mounting plate to the wall, remove the safety
pin (see image 4). Insert the screw provided until the screw head
is 5mm from the wall. Screw on the mounting bracket, do not
overtighten.
Remove the plastic sealing from the batteries and insert them into
the battery compartment. Make sure that you fit the batteries in
accordance with the polarity markings (+ or -) within the battery
compartment. If correctly installed, the alarm will give a short
beep. It indicates that the power supply is normally connected, and
that the indicator lights and buzzer are working normally.
Assemble the alarm onto the mounting plate (see image 5). Insert
the safety pin to secure the alarm to mounting plate (see image
5.1 for location).
OPERATING YOUR CO ALARM
Normal Operation
When no carbon monoxide is present, the green “Power” indicator
LED flashes every 45 seconds and is an indication that your alarm is
powered and functional.
Fault indicator
The fault indicator flashes twice with beeps when there is a fault in
the sensor or circuit. Fault warning will be given at least once every
minute until the fault is eliminated. The CO alarm will not detect CO
and you are not protected. Contact Smartwares for assistance.
Alarm Condition
When the unit detects dangerous levels of CO, the alarm warning
will be made. The red LED flashes 15 times with 15 beeps in 4
seconds, rests for 3 seconds, then repeats. The alarm will not stop
until CO concentration is lower than 40 ppm.
CO-LEVEL (PPM) RESPONSE TIME (MIN)
27 +/- 3 ppm > 120 min.
55 +/- 5 ppm 60-90 min.
110 +/-10 ppm 10-40 min.
330 +/- 30 ppm < 3 min.
The alarm response time of this detector complies with EN
50291-1:2018.
Returning to normal operation
Put the detector in clean air, the alarm will terminate automatically in
6 minutes, or you can quit the alarm condition by pressing the TEST
button for 1 to 3 seconds and then release it.
Low Battery Signal / End of life warning
When the battery is empty the alarm will beep 1 times every 45
seconds and the green “Power” LED will flash at the same time for 7
days. The battery in the apparatus needs to be replaced as soon as
possible.
Battery levels:
When your CO alarm needs replacing, the unit will beep 2 times and
yellow “Fault” LED indicator will flash 2 times. The apparatus must
be replaced with a new CO alarm as soon as possible.
Low CO concentration warning
Prolonged exposure to low levels of CO can impair the health of
vulnerable groups such as children, pregnant women, elderly or
patients.
When CO concentration is greater than 30 ppm for a duration of over
60 minutes, or when CO concentration is greater than 40 ppm for a
duration of over 40 minutes, low CO concentration warning is given
once every 3-5 minutes. The alarm indicator flashes 4 times with
beeps at a lower speed.
TESTING YOUR CO ALARM
It is recommended that you test your CO alarm once a month to
ensure the alarm is working correctly by pressing and holding the
test button on the front of the alarm for 2 seconds. If the detector is
working properly, the alarm will sound 5 beep tones and the red LED
will flash at the same time. If there is malfunction, then the fault
warning will show.
ALARM SILENCE
Alarm silence mode only works in alarm condition.
To activate silence mode, the CO concentration must be less than
200 ppm , press and hold the TEST button for 1 to 3 seconds until
you see the alarm indicator flash with no beep. Alarm silence
condition is the same as alarm condition except the buzzer is silent
temporarily. The alarm indicator still flashes.
Alarm silence condition lasts maximum 10 minutes.
Press the TEST button in alarm silence condition, and it will recover
alarm condition immediately.
When the alarm silence condition ends it will recover alarm
condition.
MAINTAINING YOUR CO ALARM
Your alarm will alert you to potentially hazardous CO concentrations
in your home when maintained properly. To maintain your alarm in
proper working order, it is recommended that you:
Test your alarm at least once a month.
Clean your CO alarm regularly to prevent dust build up. This can
be done using a vacuum cleaner with the brush attachment once
per month. Clean gently around the front grilled section and sides.
Never use cleaning solutions on your alarm. Simply wipe with a
damp cloth.
Do not paint the alarm.
Do not block or cover the alarm’s venthole with paste adhesive or
other things.
ATTENTION:
When scouring or stripping a wooden floor, painting, wallpapering or
using adhesive or aerosol, you should remove the carbon monoxide
detector and keep it in a safe place to prevent damaging the sensor.
High concentrations of the following substances can damage the
sensor, which often results in a false alarm: methane, propane,
isopropyl butane, ethylene, ethanol, alcohol, isopropyl alcohol,
benzene, toluene, ethyl acetate, hydrogen, hydrogen sulfate and
sulfur dioxide. Also aerosol sprays, alcoholic products, paint,
solvents, adhesive, hair spray, aftershave, perfume and certain
cleaning agents can cause damage.
WHAT TO DO IN THE EVENT OF AN ALARM
In the event the CO alarm raises an alarm:
Immediately move to fresh air outdoor or open all doors/windows to
ventilate the area and allow the carbon monoxide to disperse. Where
possible turn off fuel burning appliance. Evacuate the building and
do not re-enter the premises nor move away from the open door/
window until emergency services responders have arrived, the
premises have been aired out, and your alarm remains in its normal
condition. Seek medical help immediately for anyone suffering from
the symptoms of headache, drowsiness, nausea, etc. Do not use the
appliances again until they have been checked by a qualified
technician and the fault located and cleared.
This product is not designed for use in a recreational vehicle or
mobile home. The alarm should be installed by a competent person.
This apparatus is designed to protect individuals from the acute
effects of carbon monoxide exposure. It will not fully safeguard
individuals with specific medical conditions. If in doubt consult a
medical practitioner.
The installation of this CO alarm should not be used as a substitute
for proper installation, use and maintenance of fuel burning
appliances including appropriate ventilation and exhaust systems.
TECHNICAL DATA
Power Source DC 4.5V Alkaline battery type: 3
x LR6 1,5VDC
Sensor Type Electrochemical sensor
Type of Gas sensed Carbon Monoxide
Sensor Lifetime 10 Year
Alarm activation 27 +/- 3 ppm (after 120 min.)
55 +/-5 ppm (Between 60-90
min.)
110 +/- 10 ppm (Between 10-40
min.)
330 +/- 30 ppm (Within 3
minutes)
Operation Temperature 0°C~45°C (storage: -20°~50°C ±
2°C)
Ambient Humidity 0%~70% RH (storage: 0%~90%
RH)
Horn Level >85 Decibels at 3 meter
Battery Life 5 years
For indoor use only.
Please read manual before use, and store it carefully for future use
and maintenance.
For DoC go to: www.smartwares.eu/doc and follow instructions.
Condition LED Sound
Normal operation Green LED flashes
every 45 seconds
None
Testing Red LED flashes
rapidly
5 beeps
Alarm Red LED flashes 15
times in 4 seconds.
Rest 3 seconds, then
repeats
15 beeps in 4
seconds, rest 3
seconds, then
repeats
Malfunction Yellow LED flashes 2
times every 11
seconds
2 beeps every 11
seconds
Low battery signal Yellow LED flashes
every 45 seconds
1 beep every 45
seconds
End of life Yellow LED flashes 2
times, END is shown
on display
2 beeps every 60
seconds
DE Bedienungsanleitung
ALLGEMEINES
Vielen Dank für den Kauf dieses Smartwares CO-Melders! Lesen
Sie vor der Benutzung des Produkts bitte aufmerksam diese
Betriebsanleitung. Bewahren Sie sie für zukünftige Zwecke und die
Instandhaltung an einem sicheren, leicht zugänglichen Ort auf. Falls
Sie Fragen haben oder weitere Informationen über den CO-Melder
oder das Vermeiden einer Kohlenmonoxidvergiftung benötigen,
besuchen Sie bitte unsere Website: www.smartwares.eu.
Fabrikations-/Modellnummer: FGA-1305
Batteriebetriebener Kohlenmonoxidmelder mitBeschreibung:
einem elektrochemischen Sensor und 5Jahren Lebensdauer
unter normalen Betriebsbedingungen. Dieses Gerät enthält 3 AA
1,5VDC LR6 Alkalibatterien (insg. 4,5V) mit einer Haltbarkeit von
5Jahre und wird inklusive Befestigungsdübel und -schraube
geliefert.
Der CO-Melder soll Personen beim AuftretenFunktionsweise:
von Kohlenmonoxid alarmieren und ausreichend Zeit geben, um
angemessen auf die Gefahr zu reagieren.
CO-Melder für Wohngebäude.Anwendungsbereich:
WICHTIG:
Der Melder ist dafür vorgesehen, KohlenmonoxidVorsicht:
festzustellen, und kann keine Undichtigkeiten verhindern!
Der CO-Melder darf keinesfalls mit Farbe angestrichenVorsicht:
oder auf irgendeine Art bedeckt werden, um die einwandfreie
Funktion zu gewährleisten.
Der CO-Melder muss spätestens 10Jahre nachWarnung:
seinem Produktionsdatum ersetzt werden.
Nach 10Jahren Betriebsdauer kann das Produkt nicht mehr benutzt
werden. Notieren Sie sich das Ersetzungsdatum im Kalender oder
melden Sie sich kostenlos an unter: www.smartreminder.eu
LED-Anzeigen (siehe Abb. 1)
1. Alarm
2. Fehler
3. Strom
WAS IST KOHLENMONOXYD?
Kohlenmonoxid (CO) ist ein schleichendes Gift, das freigesetzt wird,
wenn Brennstoffe verbrannt werden. Es ist ein farb-, geruch- und
geschmackloses Gas und mit den menschlichen Sinnen daher
äußerst schwer festzustellen. Jedes Jahr werden Hunderte von
Personen durch Kohlenmonoxid getötet und viele mehr verletzt. Es
bindet sich an das Hämoglobin im Blut und reduziert den im Körper
zirkulierenden Sauerstoffgehalt. In hohen Konzentrationen kann CO
innerhalb von Minuten tödlich wirken. CO entsteht bei
unvollständiger Verbrennung von Brennstoffen wie Holz, Holzkohle,
Kohle, Heizöl, Kerosin, Benzin, Erdgas, Propangas, Butangas usw.
Beispiele für CO-Quellen:
Laufender Motor in einer Garage Gasgeräte
Öl- und Gasheizungen Mobile Generatoren
Kaminöfen Gas- oder Kerosin-Heizgeräte
Grillgeräte Verstopfte Kamine
Holz- und Gaskamine Heizkessel
SYMPTOME EINER CO-VERGIFTUNG
Die folgenden Symptome lassen auf eine mögliche CO-Vergiftung
schließen (ppm = parts per million/ 1:1000.000):
35 ppm Die maximal zulässige Konzentration für eine
dauerhafte Exposition bei gesunden Erwachsenen
über 8Stunden.
200 ppm Leichte Kopfschmerzen, Müdigkeit, Übelkeit nach
2-3Stunden.
400 ppm Frontal-Kopfschmerzen binnen 1-2Stunden,
lebensbedrohlich nach 3Stunden.
800 ppm Schwindel, Übelkeit und Krämpfe binnen 45Minuten.
Bewusstlosigkeit binnen 2Stunden. Tod binnen
3Stunden.
1600 ppm Kopfschmerzen, Schwindel und Übelkeit binnen
20Minuten. Tod binnen 1Stunde.
6400 ppm Kopfschmerzen, Schwindel und Übelkeit binnen
1-2Minuten.
Warnung: Das Gerät kann nicht die chronischen Folgen einer CO-
Exposition verhindern oder Personen mit einem spezifischen Risiko
schützen. Achten Sie daher stets auf die Symptome einer
Kohlenmonoxidvergiftung
PLATZIERUNG DES CO-MELDERS
Der CO-Melder ist dafür vorgesehen, giftige CO-Dämpfe zu
erkennen, die durch eine unvollständige Verbrennung entstehen
(z.B. durch Geräte, Öfen, Kamine und Autoabgase). Falls Ihre
Wohnung nur eine Etage hat, sollten Sie zum minimalen Schutz
einen Melder in den Schlafzimmern oder im Flur von
Schlafbereichen platzieren. Bringen Sie ihn möglichst nahe an den
Schlafbereichen an und sorgen Sie dafür, dass der Melder zu hören
ist, wenn die Schlafzimmer belegt sind. Bei mehreren Etagen ist zum
minimalen Schutz mindestens ein Melder pro Etage vorzusehen.
HINWEIS: Für einen maximalen Schutz sollte ein Melder in jedem
Raum oder in dessen Nähe platziert werden, in dem sich eine
Feuerstätte befindet (z.B. Gasheizungen, Zentralheizkessel,
Raumheizgeräte, Wasserboiler, Herde, Grillgeräte usw.).
VORSICHT: Das Gerät schlägt bei erhöhten CO-Konzentrationen im
unmittelbaren Sensorbereich an. Beachten Sie, dass auch in
anderen Bereichen eine erhöhte CO-Konzentration vorliegen kann.
Achtung: CO-Melder ersetzen in keinem Falle Rauch- oder andere
Gasmelder.
PLATZIERUNG DES CO-MELDERS (siehe Abb. 2)
Kohlenmonoxid (CO) hat eine ähnliche Dichte wie warme Luft. Damit
der Melder möglichst effizient funktioniert, sollte er wie folgt
angebracht werden: In Räumen mit einer Feuerstätte vermischt sich
CO mit der warmen Luft und steigt auf. Bringen Sie den CO-Melder
an der Wand (30-80cm unterhalb der Decke), aber oberhalb von
Türen oder Fenstern in einem horizontalen Abstand von mindestens
150cm von der potenziellen CO-Quelle an. Der Melder kann auch
an der Decke angebracht werden.
In Räumen, in denen Menschen schlafen oder sich längere Zeit
aufhalten (Schlafzimmer, Wohnzimmer), bringen Sie den CO-Melder
in Atemhöhe an. Für weitergehende Hinweise und Beispiele siehe
www.smartwares.eu.
Folgende Bereiche sind u.a. zu meiden:
Fälle, in denen die Temperatur unter 0°C fallen oder auf mehr als
45°C steigen kann
Bereiche, in denen aufgrund hoher Staub-, Schmutz- oder
Sprühnebelbelastung mit starker Verschmutzung und einem
Ausfall des Sensors zu rechnen ist.
Hinter Vorhängen oder Möbelstücken.
Im Bereich von Warmluftströmen aus Öfen, Klimaanlagen oder
Lüftern.
Im Außenbereich.
Direkt oberhalb von Spülbecken oder Küchenherden.
Wo viel Ruß oder Staub den Sensor blockieren könnte
Zu feuchte Bereiche
VORSICHT: Dieser CO-Melder ist nur für den Innenbereich
vorgesehen. Er darf weder Regen noch Feuchtigkeit ausgesetzt
werden. Wenn die Batterie leer ist, schützt er schützt mehr vor der
Gefahr einer Kohlenmonoxidvergiftung. Der Melder darf weder
geöffnet noch manipuliert werden, weil dies zu Fehlfunktionen und
der Gefahr eines Stromschlags führen könnte.
MONTAGE DES CO-MELDERS
Bevor Sie den CO-Melder installieren, müssen Sie das Typenschild
in Ihrer jeweiligen Landessprache am Melder anbringen.
Um sicherzustellen, dass das Produkt korrekt installiert und benutzt
wird, sollte es strikt nach den Anweisungen in diesem Handbuch
oder von Fachpersonal montiert werden. Dieser CO-Melder wird von
einer Batterie gespeist und braucht keine zusätzliche Verdrahtung.
Achten Sie darauf, dass der Melder in allen Schlafräumen zu hören
ist, oder bringen Sie mehrere Melder an.
Wandmontage:
Achten Sie bei der Installation insbesondere auf elektrische
Unterputzleitungen oder Rohre im Bereich der
Montagebohrungen.
Markieren Sie das Befestigungsloch, bohren Sie ein Loch mit
6mm Durchmesser und 40mm Tiefe an dieser Stelle und setzen
Sie den Dübel ein.
Entfernen Sie den Sicherungsstift, bevor Sie die Montageplatte an
der Wand befestigen (siehe Abb. 4). Drehen Sie die mitgelieferte
Schraube hinein, bis der Schraubenkopf 5mm von der Wand
entfernt ist. Schrauben Sie die Montagehalterung fest. Nicht zu
stark anziehen.
Entfernen Sie die Plastikversiegelung von den Batterien und
setzen Sie sie in das Batteriefach ein. Achten Sie darauf, die
Batterien gemäß der Polaritätskennzeichnung (+ oder -) im
Batteriefach einzusetzen. Bei korrekter Installation gibt der Melder
einen kurzen Piepton ab. Dies bedeutet, dass die
Stromversorgung intakt ist und die Kontrollleuchten und der
Summer normal funktionieren. Befestigen Sie den Melder auf der
Montageplatte (siehe Abb. 5). Setzen Sie den Sicherungsstift ein,
um den Melder an der Montageplatte zu fixieren (siehe Abb. 5.1
zur Anordnung).
BEDIENUNG DES CO-MELDERS
Normalbetrieb
Wenn kein Kohlenmonoxid vorhanden ist, blinkt die grüne LED
„Power“ alle 45Sekunden als Hinweis darauf, dass Ihr Alarm
eingeschaltet und betriebsbereit ist.
Fehleranzeige
Bei einer Sensor- oder Schaltungsstörung blinkt die Fehleranzeige
zweimal und es ertönt ein Signalton. Die Störungswarnung erfolgt
mindestens einmal pro Minute so lange, bis der Fehler behoben ist.
Der CO-Melder kann kein Kohlenmonoxid feststellen und Sie sind
nicht geschützt. Wenden Sie sich zwecks Unterstützung an
Smartwares.
Alarmstatus
Wenn das Gerät gefährliche CO-Gehalte erkennt, wird Alarm
gegeben. Die rote LED blinkt 15 Mal mit 15Pieptönen alle
4Sekunden; nach 3Sekunden Pause wird der Vorgang wiederholt.
Der Alarm hört erst wieder auf, wenn die CO-Konzentration unter
40ppm absinkt.
DECLARATION OF CONFORMITY- For DoC go to:
www.smartwares.eu/doc and follow the instructions.
FGA-1305
Conform with EN50291-1:2018
EN Carbon monoxide detector / Manual
DE Kohlenmonoxid Melder / Gebrauchsanweisung
FR Détecteur de monoxyde de carbone / Mode d’emploi
NL Koolmonoxide detector / Gebruiksaanwijzing
ESDetector de monóxido de carbono / Instrucciones de uso
IT Rilevatore di monossido di carbonio / Manuale
PLCzujnik tlenku wegla (czadu) / instrukcje
SV Kolmonoxid detektor / Bruksanvisnin


Produkt Specifikationer

Mærke: Smartwares
Kategori: Gasdetektor
Model: FGA-13051
Bredde: 106 mm
Dybde: 76 mm
Højde: 35 mm
Antal pr. pakke: 1 stk
Brugervejledning: Ja
Produktfarve: Hvid
Indbygget skærm: Ingen
Husmateriale: Acrylonitrilbutadienstyren
Batterier inkluderet: Ja
LED-indikatorer: Ja
Strømkilde type: Batteri
Kan forbindes indbyrdes: Ingen
Test-knap: Ja
Alarm decibel: 85 dB
Monteringstype: Væg
DC indgangsspænding: 4.5 V
Monteringssæt: Ja
Lydalarmer: Ja
Maksimal dækning: 40 m²
Bedste anvendelsesmuligheder: Home, Office
Produkt levetid: 10 År
Registrerede gastyper: Carbon monoxide (CO)

Har du brug for hjælp?

Hvis du har brug for hjælp til Smartwares FGA-13051 stil et spørgsmål nedenfor, og andre brugere vil svare dig