Supermicro SuperServer 7048R-C1R4+ Manual
Supermicro
Server
SuperServer 7048R-C1R4+
Læs nedenfor 📖 manual på dansk for Supermicro SuperServer 7048R-C1R4+ (132 sider) i kategorien Server. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/132

®
S SUPER ERVER®
7048R-C1RT4+
7048R-C1R4+
SUPER
USER’S MANUAL
1.0

The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and docu-
mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn-
ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other repro-
ductive harm.
Manual Revision 1.0
Release Date: October 9, 2014
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2014 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America

S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
iv
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X10DRC-T4+/LN4+ serverboard,
including the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconguring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC745TQ-R1K03B/SC745TQ-
R920B server chassis. You should follow the procedures given in this chapter
when installing, removing or reconguring SAS/SATA or peripheral drives and when
replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specications

Notes
Preface
v

vi
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors 1-2 ......................................................................................................
Memory 1-2 ...........................................................................................................
SAS 1-2 ................................................................................................................
SATA .............................................................................................................. 1-2
PCI Expansion Slots ....................................................................................... 1-2
Rear I/O Ports ................................................................................................. 1-3
1-3 Server Chassis Features ................................................................................1-3
System Power ................................................................................................. 1-3
Front Control Panel ......................................................................................... 1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro .................................................................................... 1-5
Chapter 2 Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-1
2-4 Warnings and Precautions .............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-5 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ..................................................... 2-4
Installing the Chassis Rails ............................................................................. 2-5
Installing the Rack Rails ................................................................................. 2-6
Installing the Server into the Rack .................................................................. 2-7
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual

vii
Power 3-1 ..............................................................................................................
Reset 3-1 ...............................................................................................................
3-3 Control Panel LEDs ........................................................................................ 3-2
Power 3-2 ..............................................................................................................
HDD 3-2 .................................................................................................................
NIC1 3-2 ................................................................................................................
NIC2 3-2 ................................................................................................................
Information LED .............................................................................................. 3-3
Power Fail ....................................................................................................... 3-3
3-4 Drive Carrier LEDs .........................................................................................3-3
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning Denition ........................................................................................... 4-1
Installation Instructions .................................................................................... 4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................ 4-10
Redundant Power Supplies .......................................................................... 4-12
Backplane Voltage ........................................................................................ 4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning ................................................................................. 4-16
Power Cable and AC Adapter ...................................................................... 4-18
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions 5-1 .....................................................................................................
Unpacking 5-1 .......................................................................................................
5-2 Processor and Heatsink Installation................................................................ 5-2
Installing a Passive CPU Heatsink ................................................................. 5-5
Removing the Heatsink ................................................................................... 5-5
5-3 Connecting Cables .......................................................................................... 5-6
Connecting Data Cables ................................................................................. 5-6
Connecting Power Cables ..............................................................................5-6
5-4 I/O Ports .......................................................................................................... 5-7
LAN Ports ........................................................................................................ 5-7
5-5 Installing Memory ............................................................................................ 5-8
Table of Contents

viii
Memory Support .............................................................................................. 5-9
Processor & Memory Module Population Conguration ............................ 5-9
5-6 Serverboard Details .......................................................................................5-11
Serverboard Quick Reference....................................................................... 5-12
5-7 Connector Denitions .................................................................................... 5-14
Front Control Panel ....................................................................................... 5-15
Rear I/O Shield ............................................................................................. 5-17
Other Connectors .......................................................................................... 5-19
5-8 Jumper Settings ............................................................................................ 5-22
5-9 Onboard Indicators ........................................................................................ 5-24
5-10 SATA/SAS Connections ................................................................................ 5-26
5-11 Installing Software ......................................................................................... 5-27
SuperDoctor® 5 ............................................................................................ 5-28
5-12 Onboard Battery ............................................................................................ 5-29
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions 6-1 .....................................................................................................
6-2 Front Control Panel ......................................................................................... 6-3
6-3 System Fans ................................................................................................... 6-4
Fan Failure ...................................................................................................... 6-4
6-4 Drive Bay Installation ...................................................................................... 6-6
SAS/SATA Hard Drives ................................................................................... 6-6
SAS/SATA Backplane ...................................................................................... 6-7
Mobile Rack (Storage Module) ....................................................................... 6-8
6-5 Power Supply ................................................................................................ 6-10
Power Supply Failure .................................................................................... 6-10
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Conguration Data ......................................................... 7-1
How to Start the Setup Utility ......................................................................... 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Congurations...................................................................... 7-4
7-4 Event Logs .................................................................................................... 7-32
7-5 IPMI ............................................................................................................... 7-34
7-6 Security Settings ........................................................................................... 7-36
7-7 Boot Settings ................................................................................................. 7-37
7-8 Save & Exit ................................................................................................... 7-39
Appendix A BIOS Error Beep Codes
Appendix B System Specications
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual

Chapter 1
Introduction
1-1 Overview
The SuperServer 7048R-C1RT4+/7048R-C1R4+ is a high-end server comprised of
two main subsystems: the SC745TQ-R1K03B/SC745TQ-R920B 4U server chassis
and the X10DRC-T4+/LN4+ dual processor serverboard. Please refer to our web
site for information on operating systems that have been certied for use with the
system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been
included with the 7048R-C1RT4+/7048R-C1R4+, as listed below:
•Two passive CPU heatsinks (SNK-P0048P)
•Three 8-cm system fans (7048R-C1RT4+: FAN-0127L4, 7048R-C1R4+: FAN-
0074L4)
•Two 8-cm rear exhaust fans (FAN-0082L4)
•Air shrouds (7048R-C1RT4+: 1x MCP-310-74501-0B, 1x MCP-310-49001-0N;
7048R-C1R4+: MCP-310-49001-0N)
•SAS/SATA Accessories
One SAS/SATA backplane (BPN-SAS-743TQ)
Eight drive carriers (MCP-220-00092-0B)
•One mobile rack unit to support eight 2.5" HDDs (CSE-M28SACB-OEM)
Optional
•One rackmount kit (CSE-PT26L)
Note: For your system to work properly, please follow the links below to download
all necessary drivers/utilities and the user’s manual for your server.
•Supermicro product manuals: http://www.supermicro.com/support/manuals/
•Product drivers and utilities: ftp://ftp.supermicro.com
•Product safety info: http://super-dev/about/policies/safety_information.cfm
Chapter 1: Introduction
1-1

1-3
Chapter 1: Introduction
Rear I/O Ports
The I/O ports include two COM ports (one Fast UART 16550 external serial port, one
serial port header), two VGA ports (1x rear, 1x internal), a dedicated IPMI LAN port
and seven USB ports (2x rear, 4x header, 1x type A). It also offers four LAN ports:
•X10DRC-LN4+ has Gigabit ports.
•X10DRC-T4+ has 10GBaseT ports.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC745TQ-R1K03B/
SC745TQ-R920B server chassis.
System Power
The SC745TQ-R1K03B features a redundant, hot-plug 1000W power supply com-
posed of two separate power modules. The SC745TQ-R920B features a redundant,
hot-plug 920W power supply composed of two separate power modules. The power
redundancy feature allows you to replace a failed power supply without shutting
down the system.
Front Control Panel
The control panel on the SuperServer 7048R-C1RT4+/7048R-C1R4+ provides you
with system monitoring and control. LEDs indicate system power, HDD activity,
network activity, system overheat and power supply failure. A main power button
and a system reset button are also included. In addition, two USB ports have been
incorporated into the control panel to provide front side USB access.
Cooling System
The chassis has an innovative cooling design that includes three 8-cm hot-plug
system cooling fans located in the middle section of the chassis as well as two 8-cm
hot-plug exhaust fans located at the rear of the chassis. An air shroud channels the
airow from the system fans to efciently cool the processor area of the system.
The power supply module also includes a cooling fan.

1-4
S SUPER ERVER 7048R-C1RT/7048R-C1R User's Manual
Figure 1-1. Chipset Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
P0
P0
P1
P1
DD
EEE
FFF
G
G
G
H
H
H
CPU 1
CPU 0
PCI-E p12-x16 SLOT 3
PCI-E
SATA #1
SATA #2
DDR4 DIMM
SATA #3
SATA #4
SATA #5
SATA #6
USB 3.0
SATA
DDR4 DIMM
#3
#2
#1
DDR4 DIMM
G
A
LPC
USB 3.0
LAN
I350/
X540/
SAGEVILL
ABD BC
PROCESSOR
HASWELL
A
C
PROCESSOR
HASWELL
A
B
C
QPI
#1
DDR4 DIMM
#2
#3
DDR4 DIMM
PCI-E p12-x8 SLOT 4
DDR4 DIMM
x16
LSI
3108
x8
x8 (0-7)
TPM HDR
PCH
WELLSBURG
QPI
x16
DMI
VGA BMC
VGA
CONN
AST2400
DDR 3
DDR4 DIMM
PHY1
LAN
RTL8211
B
PCI-E p12-x8 SLOT 6
PCI-E p12-x16 SLOT 5
DDR4 DIMM
PCI-E p12-x8 SLOT 2
PCI-E X1 G2
D
C
H
F
E
Socket 00
Socket 01
#1#2
#3
#1#2#3
#1
#2
#3
#1
#2
#3
#1
#2
#3
#1
#2
#3
SYSTEM
BIOS
SPI
SPI
COM
SATA #7
SATA #8
SATA #9
SATA #10
BMC BOOT FLASH
12345
USB
LAN
x8 (8-15)
9.6G
6GB/s
x8
x16
x16
PCI-E p12-x8 SLOT 1
x8 x8 x8
SPI
USB2.0
USB2.0
I350/
X540/
SAGEVILL
Gen2 x4
x16
Gen2 x4
USB 2.0
123456
USB
USB 2.0
9
8
7
x8
x16
(7-0)
(15-8)
(15-0)
RJ45 RJ45
RJ45 RJ45
PE PE2 3 PE1 DM1
PE2PE PE3 1 DM1

1-5
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Website: www.supermicro.nl
Asia-Pacic
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Website: www.supermicro.com.tw

1-6
S SUPER ERVER 7048R-C1RT/7048R-C1R User's Manual
Notes

Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 7048R-
C1RT4+/7048R-C1R4+ up and running. Following these steps in the order given
should enable you to have the system operational within a minimum amount of
time. This quick setup assumes that your system has come to you with the proces-
sors and memory preinstalled. If your system is not already fully integrated with a
serverboard, processors, system memory etc., please turn to the chapter or section
noted in each step for details on installing specic components.
The 7048R-C1RT4+/7048R-C1R4+ may be employed either as a tower or mounted
in a rack as a 4U rackmount chassis.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged
in any way. If the server itself shows damage you should le a damage claim with
the carrier who delivered it.
Decide on a suitable location for the SuperServer 7048R-C1RT4+/7048R-C1R4+.
It should be situated in a clean, dust-free area that is well ventilated. Avoid areas
where heat, electrical noise and electromagnetic elds are generated. You will also
need it placed near a grounded power outlet. Be sure to read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the system was shipped in may include two sets of rail assemblies, two
rail mounting brackets and mounting screws needed for installing the system into
a rack (optional kit). Follow the steps in the order given to complete the installation
process in a minimum amount of time. Please read this section in its entirety before
you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
•Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for sufcient airow and ease in servicing.

2-2
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
•This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Rack Precautions
•Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
•In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
•Always make sure the rack is stable before extending a component from the
rack.
•You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
•Slide/rail-mounted equipment is not to be used as a shelf or workspace.
Server Precautions
•Review the electrical and general safety precautions in Chapter 4.
•Determine the placement of each component in the rack you install the before
rails.
•Install the heaviest server components on the bottom of the rack rst, and then
work up.
•Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
•Allow the hot plug drives and power supply modules to cool before touching
them.
•Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.

Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airow
Equipment should be mounted into a rack so that the amount of airow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable.
The following guidelines are provided to ensure your safety:
•This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
•When mounting this unit in a partially lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
•If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.

2-4
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
2-5 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack
installation requires the use of the optional rackmount kit. If the system has already
been mounted into a rack or if you are using it as a tower, you can skip ahead to
Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. The following is a guideline for installing the server into
a rack with the rack rails provided in the rackmount kit. You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
The optional rackmount kit includes two rack rail assemblies. Each of these as-
semblies consist of three sections: an inner xed chassis rail that secures to the
chassis, an outer rack rail that secures directly to the rack itself and two rail brackets,
which also attach to the rack (see Figure 2-1.) The inner and outer rails must be
detached from each other to install.
To remove the inner chassis rail, pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Depress the locking tab to pull the inner rail completely out. Do this for
both assemblies (one for each side).
Figure 2-1. Identifying the Sections of the Rack Rails
Inner rail
Outer rail
Rail brackets
Warning: When initially installing the server to a rack, test that the rail
locking tabs engage to prevent the server from being overextended. Have
a rack lift in place as a precaution in case the test fails.

Chapter 2: Server Installation
2-5
Installing the Chassis Rails
You will need to remove the top cover and the feet to add rack rails to the chassis.
First, remove the top and right covers (top and left covers when standing as a tower
chassis) by rst removing the screws that secure them to the chassis. Depress the
button on the top (side if tower) of the chassis to release the cover and then pull
the cover off. Then unscrew the four feet and remove them from the chassis (see
Figure 2-2).
You can now attach rack rails to the top and bottom (now the sides) of the chassis.
First add the rack handles. Then position the inner chassis rail sections you just
removed along the side of the chassis making sure the screw holes line up. Note
that these two rails are left/right specic. Screw the rail securely to the side of the
chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side
of the chassis. You will also need to attach the rail brackets when installing into a
telco rack.
Locking Tabs: As mentioned, the chassis rails have a locking tab, which serves
two functions. The rst is to lock the server into place when installed and pushed
fully into the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended from the rack. This prevents the server from
coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Preparing to Install the Chassis Rails
Warning: In any instance of pulling the system from the rack, always use
a rack lift and follow all associated safety precautions.

2-6
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Installing the Rack Rails
Determine where you want to place the SuperServer 7048R-C1RT4+/7048R-C1R4+
in the rack. (See Rack and Server Precautions in Section 2-3.) Position the xed
rack rail/sliding rail guide assemblies at the desired location in the rack, keeping
the sliding rail guide facing the inside of the rack. Screw the assembly securely to
the rack using the brackets provided. Attach the other assembly to the other side
of the rack, making sure both are at the exact same height and with the rail guides
facing inward.
Figure 2-3. Installing the Rails to the Chassis
Warning: Do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Warning: Stability hazard. The rack stabilizing mechanism must be in
place, or the rack must be bolted to the oor before you slide the unit out
for servicing. Failure to stabilize the rack can cause the rack to tip over.
Warning: Slide rail mounted equipment is not to be used as a shelf or a
work space.

Chapter 2: Server Installation
2-7
Figure 2-4. Installing the Server into a Rack
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. You should have two brackets in the rack
mount kit. Install these rst keeping in mind that they are left/right specic (marked
with "L" and "R"). Then, line up the rear of the chassis rails with the front of the rack
rails. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack (see Figure 2-4).
Note: Figure is for illustrative purposes only. Always install servers to the bottom
of a rack rst.

Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
The control panel on the 7048R-C1RT4+/7048R-C1R4+ has several LEDs and two
buttons. There are also two LEDs on each hard drive carrier. These LEDs keep you
constantly informed of the overall status of the system and the activity and health
of specic components.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a power on/off
button and a reset button.
Power
This is the main power button, which is used to apply or turn off the main system
power. Turning off system power with this button removes the main power but keeps
standby power supplied to the system.
Reset
Use the reset button to reboot the system.

3-4
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Notes

4-1
Chapter 4: Warning Statements for AC Systems
Chapter 4
Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certied technicians should attempt to install or congure
components.
Read this appendix in its entirety before installing or conguring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.
Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
Warning Denition
警告の定義
この警告サインは危険を意味します。
人身事故につながる可能性がありますので、いずれの機器でも動作させる前に、
電気回路に含まれる危険性に注意して、標準的な事故防止策に精通して下さい。
此警告符号代表危险。
您正处于可能受到严重伤害的工作环境中。在您使用设备开始工作之前,必须充分
意识到触电的危险,并熟练掌握防止事故发生的标准工作程序。请根据每项警告结
尾的声明号码找到此设备的安全性警告说明的翻译文本。
此警告符號代表危險。
您正處於可能身體可能會受損傷的工作環境中。在您使用任何設備之前,請注意觸
電的危險,並且要熟悉預防事故發生的標準工作程序。請依照每一注意事項後的號
碼找到相關的翻譯說明內容。

4-2
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie benden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
nal de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
gurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la n de chaque avertissement.
CONSERVEZ CES INFORMATIONS.
ןונקת תורהצהאהרהז
ןה תואבה תורהצהא ינפמ שמתשמה תא ריהזהל תנמ לע ,היישעתה ינקת יפ לע תורהז הלבח
ה וא תולאש שיו הדימב .תירשפא תיזיפי ,יהשלכ היעבב תולקתרוציל שי הכימת תקלחמ םע רשק
רידגהל וא ןיקתהל םיאשר דבלב םיכמסומ םיאנכט .ורקימרפוס לש תינכ תאה .םיביכר
אורקל שי .ורקימרפוס יזראמב םיביכרה תרדגה וא תנקתה ינפל ואולמב חפסנה תא

4-3
Warning Statements for AC Systems
!
.
.
.
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken,
dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's
en dient u op de hoogte te zijn van de standaard procedures om ongelukken te
voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te
herleiden naar de desbetreffende locatie.
BEWAAR DEZE INSTRUCTIES
. !

4-4
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Installation Instructions
Warning!
Read the installation instructions before connecting the system to the power source.
Warnung
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen
lesen.
¡Advertencia!
Lea las instrucciones de instalación antes de conectar el sistema a la red de
alimentación.
Attention
Avant de brancher le système sur la source d'alimentation, consulter les directives
d'installation.
設置手順書
システムを電源に接続する前に、設置手順書をお読み下さい。
אורקל שי רוקמל תכרעמה רוביח ינפל הנקתה תוארוה תאחתמ.
.
Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron
aansluit.
警告
将此系统连接电源前,请先阅读安装说明。
警告
將系統與電源連接前,請先閱讀安裝說明。

4-6
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Power Disconnection Warning
電源切断の警告
システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス
するには、
システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り
外す必要があります。
警告
在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es
auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder
zu entfernen.
Warning!
The system must be disconnected from all sources of power and the power cord
removed from the power supply module(s) before accessing the chassis interior to
install or remove system components.
!
()
. 250V(), 20A()
.
Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van
uw electrische installatie. Controleer of het beveiligde aparaat niet groter
gedimensioneerd is dan 220V, 20A.

4-7
Chapter 4: Warning Statements for AC Systems
¡Advertencia!
El sistema debe ser disconnected de todas las fuentes de energía y del cable
eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso
el interior del chasis para instalar o para quitar componentes de sistema.
Attention
Le système doit être débranché de toutes les sources de puissance ainsi que de
son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour
installer ou enlever des composants de systéme.
!הרהזא
למשחה תורוקמ לכמ תכרעמה תא קתנל ריסהל שיו קפסהמ ילמשחה לבכ תא
נקתה ךרוצל זראמה לש ימינפה קלחל השיג ינת רסה ואת .םיביכר
!
.
Waarschuwing
Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren
of verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle
stroomkabels aangesloten op de voeding(en) van de behuizing te verwijderen

4-8
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Equipment Installation
機器の設置
トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可
されています。
Warning!
Only trained and qualied personnel should be allowed to install, replace, or service
this equipment.
Warnung
Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem,
qualiziertem Personal gestattet werden.
¡Advertencia!
Solamente el personal calicado debe instalar, reemplazar o utilizar este equipo.
Attention
Il est vivement recommandé de confier l'installation, le remplacement et la
maintenance de ces équipements à des personnels qualiés et expérimentés.
!הרהזא
שר דבלב ךמסומ תווצתא ףילחהל ,ןיקתהל יא .דויצה רובע תוריש תתל וא דויצה
!
,
.
警告
只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。
警告
只有經過受訓且具資格人員才可安裝、更換與維修此設備。

4-9
Chapter 4: Warning Statements for AC Systems
アクセス制限区域
このユニットは、アクセス制限区域に設置されることを想定しています。
アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いての
み出入りが可能です。
Warning!
This unit is intended for installation in restricted access areas. A restricted access
area can be accessed only through the use of a special tool, lock and key, or other
means of security. (This warning does not apply to workstations).
Restricted Area
Waarschuwing
Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door
geschoold en gekwaliceerd personeel.
Warnung
Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen.
Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und
Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich.
¡Advertencia!
Esta unidad ha sido diseñada para instalación en áreas de acceso restringido.
Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una
herramienta especial, cerradura con llave u otro medio de seguridad.
Attention
Cet appareil doit être installée dans des zones d'accès réservés. L'accès à une
zone d'accès réservé n'est possible qu'en utilisant un outil spécial, un mécanisme
de verrouillage et une clé, ou tout autre moyen de sécurité.
警告
此部件应安装在限制进出的场所,限制进出的场所指只能通过使用特殊工具、锁和
钥匙或其它安全手段进出的场所。
警告
此裝置僅限安裝於進出管制區域,進出管制區域係指僅能以特殊工具、鎖頭及鑰匙
或其他安全方式才能進入的區域。

4-11
Chapter 4: Warning Statements for AC Systems
Warnung
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die
Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp.
Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer
que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Jeter les piles usagées conformément aux instructions du fabricant.
¡Advertencia!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta.
Reemplazar la batería exclusivamente con el mismo tipo o el equivalente
recomendado por el fabricante. Desechar las baterías gastadas según las
instrucciones del fabricante.
!הרהזא
תנכס תמייקץוציפ .הניקת אל ךרדב הפלחוהו הדימב הללוסה לש ףילחהל שי
גוסב הללוסה תא מ םאותה תרבחלמומ ןרציתצ.
תוללוסה קוליס תושמושמה עצבל שי .ןרציה תוארוה יפל
!
.
.
.
Waarschuwing
Er is ontplofngsgevaar indien de batterij verkeerd vervangen wordt. Vervang de
batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen
wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd
te worden.

4-14
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Comply with Local and National Electrical Codes
Warning!
Installation of the equipment must comply with local and national electrical codes.
地方および国の電気規格に準拠
機器の取り付けはその地方および国の電気規格に準拠する必要があります。
Warnung
Die Installation der Geräte muss den Sicherheitsstandards entsprechen.
¡Advertencia!
La instalacion del equipo debe cumplir con las normas de electricidad locales y
nacionales.
!
(Backplane)
. .
Waarschuwing
Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het
systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.
ירוחאה לנפב חתמ
זא!הרה
ךלהמב רהזיהל שי .תכרעמה לועפת ןמזב ירוחאה לנפב חתמ תנכס
.הדובעה
警告
设备安装必须符合本地与本国电气法规。
警告
設備安裝必須符合本地與本國電氣法規。

4-15
Chapter 4: Warning Statements for AC Systems
Product Disposal
Warning!
Ultimate disposal of this product should be handled according to all national laws
and regulations.
יצראה למשחה יקוח םואית
!הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תבייח דויצה.
Attention
L'équipement doit être installé conformément aux normes électriques nationales
et locales.
!
.
Waarschuwing
Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale
elektriciteitsvoorschriften.
製品の廃棄
この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要が
あります。
警告
本产品的废弃处理应根据所有国家的法律和规章进行。
警告
本產品的廢棄處理應根據所有國家的法律和規章進行。
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen
des Landes erfolgen.

4-20
S SUPER ERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Notes

5-4
S SUPER ERVER 7048R-C1R(T)4+ User's Manual
8. Make sure the locking mechanism
on the "Close 1st" lever catches the
lip of the load plate. Close and lock
the "Close 1st" lever.
Push down and lock
the
lever labeled "Open 1st"
OPEN 1st
OPEN 1st
Push down and lock the
lever labeled "Close 1st".
9. Close and lock the "Open 1st" lever.
Engage the lip of
the load plate and
locking portion of
the lever."
7. With the "Close 1st" lever fully
retracted, gently close the load
plate.
Gently close
the load plate.

Chapter 5: Advanced Serverboard Setup
5-5
Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die; the required
amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are aligned
with those on the Serverboard's and the Heatsink Bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug (to
avoid possible damage to the CPU do not over-tighten the screws.)
4. Finish the installation by fully tightening all four screws.
OPEN 1s t
Serverboard
Screw#1
Screw#2
Mounting
Holes
Screw#3
Screw#4
Removing the Heatsink
Caution: We do not recommend that the CPU or the heatsink be removed. However,
if you do need to uninstall the heatsink, please follow the instructions below to prevent
damage done to the CPU or the CPU socket.
1. Unscrew the heatsink screws in the sequence as shown in the illustration below.
2. Gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive
force when wriggling the heatsink!)
3. Once the CPU is loosened, remove the heatsink from the CPU.
4. Remove the used thermal grease and clean the surface of the CPU and the
heatsink, Reapply the proper amount of thermal grease on the surface before
reinstalling the heatsink.

5-6
S SUPER ERVER 7048R-C1R(T)4+ User's Manual
5-3 Connecting Cables
Now that the processors are installed, the next step is to connect the cables to the
serverboard. These include the data (ribbon) cables for the peripherals and control
panel and the power cables.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully
routed in precongured systems to prevent them from blocking the ow of cooling
air that moves through the system from front to back.
If you need to disconnect any of these cables, you should take care to reroute them
as they were originally after reconnecting them and be aware of the pin 1 locations.
If you are conguring the system, keep the airow in mind when routing the cables.
Connecting Power Cables
The X10DRC-T4+/LN4+ has a 24-pin ATX power connector designated "J24" and
two 8-pin primary power supply connectors designated "JPWR1" and "JPWR2" for
connection to the power supply. Connect the appropriate connector from the power
supply to these three connectors to supply power to the serverboard. See the
Connector Denitions section in this chapter for power connector pin denitions.

Chapter 5: Advanced Serverboard Setup
5-7
5-4 I/O Ports
Figure 5-2 shows the I/O ports on the rear of the system.
Figure 5-2. Rear Panel I/O Ports
LAN Ports
For the 7048R-C1RT4+ using the X10DRC-T4+ serverboard, the LAN ports offer
10GBase-T. For 7048R-C1R4+ using the X10DRC-LN4+, the LAN ports provide
1Gb speed.)
Rear I/O Ports
1. COM Port 1
2. USB Port 0 (USB 2.0)
3. USB Port 1 (USB 2.0)
4. IPMI_Dedicated LAN
5. USB Port 4 (USB 3.0)
6. USB Port 5 (USB 3.0)
7. LAN 1
8. LAN 2
9. LAN 3
10. LAN 4
11. VGA Port
12. UID Button
1 9
8
7
6
5
4
3
2
10
11 12

5-8
S SUPER ERVER 7048R-C1R(T)4+ User's Manual
5-5 Installing Memory
Note: Check the Supermicro web site for recommended memory modules.
CAUTION
Exercise extreme care when installing or removing DIMM modules
to prevent any possible damage.
Installing DIMMs
1. Insert the desired number of DIMMs into the memory slots, starting with slot
DIMMA1.
2. Push the release tabs outwards on both ends of the DIMM slot to unlock it.
3. Align the key on the DIMM module with the receptive point on the slot.
4. Use two thumbs together to press on both ends of the module straight down
into the slot until the module snaps into place.
5. Press the release tabs to the lock positions to secure the DIMM module into
the slot. See Figure 5-3.
Figure 5-3. Installing DIMM into Slot
Socket Key
Release Tab
Release Tab

Chapter 5: Advanced Serverboard Setup
5-9
Memory Support
The server features 24 DIMM slots that can support up to 1536GB of Load
Reduction (LRDIMM) or up to 768GB of Registered (RDIMM)/Non-volatile (NV-
DIMM) ECC DDR4-2133/1866/1600/1333 SDRAM or LRDIMM type memory. For
the latest memory updates, please refer to our website at http://www.supermicro.
com/products/motherboard.
Processor & Memory Module Population Conguration
For memory to work properly, follow the tables below for memory installation.
Processors and their Corresponding Memory Modules
CPU# Corresponding DIMM Modules
CPU1 P1-DIMMA1~P1-DIMMD3
P1-
DIMM-
A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3
CPU2 P2-DIMME1~P1-DIMMH3
P2-
DIMM-
E1 F1 G1 H1 E2 F2 G2 H2 E3 F3 G3 H3
Processor and Memory Module Population for Optimal Performance
Number of
CPUs+DIMMs
CPU and Memory Population Conguration Table
(For memory to work properly, please follow the instructions below.)
1 CPU &
2 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1
1 CPU &
4 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
1 CPU &
5~8 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + Any memory pairs in P1-
DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slots
2 CPUs &
4 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
2 CPUs &
6 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs &
8 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-
DIMMG1/P2-DIMMH1
2 CPUs &
9~16 DIMMs
CPU1/CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-
DIMMG1/P2-DIMMH1 + Any memory pairs in P1, P2 DIMM slots
2 CPUs &
16 DIMMs
CPU1/CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/
P2-DIMMG1/P2-DIMMH1,P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-
DIMME2/P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
2 CPUs &
16~24 DIMMs
CPU1/CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/
P2-DIMMG1/P2-DIMMH1, P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2,
P2-DIMME2/P2-DIMMF2/P2-DIMMG2/P2-DIMMH2, P1-DIMMA3/P1-DIMMB3/P1-
DIMMC3/P1-DIMMD3, P2-DIMME3/P2-DIMMF3/P2-DIMMG3/P2-DIMMH3

Chapter 5: Advanced Serverboard Setup
5-13
W
a
c
c
m
(CPU2) Slot4 PCI-Express 2.0 p59-x4 in x8 Slot from CPU2
(CPU2) Slot5 PCI-Express 3.0 x16 Slot from CPU2
(CPU2) Slot6 PCI-Express 3.0 x8 Slot from CPU2
S-SGPIO1,
T-SGPIO1/2
Seria_Link General Purpose I/O Headers 1/2/3 (for SATA ports),
(T-SGPIO1 for I-SATA0-3, T-SGPIO2 for I-SATA4/5, S-SGPIO1 for
S-SATA0-3)
SP1 Internal Speaker/Buzzer
JSTBY1 +5V Standby Power Header
(BP) USB 0/1
(2.0)
Backpanel USB 2.0 Ports 0/1
(BP) USB 4/5
(3.0)
Backpanel USB 3.0 Ports 4/5
(FP) USB 7/8
(3.0)
Front Accessible USB 3.0 Connection Header 7/8
(FP) USB 2/3
(2.0)
Front Accessible USB 2.0 Connection Header 2/3
(FP) USB 6 (3.0) Front Accessible USB 3.0 Connection Header 6
VGA Backpanel VGA Port
LED Indicators
LED Description State Status
DS13 (Note below) SAS Heartbeat LED Green: Blinking SAS Normal
LE1 Rear UID LED Blue: On Unit Identied
LE2 Onboard Power LED Green: On System PWR On
LEDM1 BMC Heartbeat Green: Blinking BMC Normal LED
LEDS5 (Note below) Green: BlinkingSAS Activity LED SAS Active
LEDS6 (Note below) SAS Error LED Red: On SAS Error(s)

5-14
S SUPER ERVER 7048R-C1R(T)4+ User's Manual
5-7 Connector Denitions
Power Connectors
A 24-pin main power supply connector
(J24), and two 8-pin CPU power connectors
(JPWR1/JPWR2) are located on the
serverboard. These power connectors
meet the SSI EPS 12V specification
and must be connected to your power
supply to provide adequate power to the
system. See the tables on the right for
pin denitions.
Caution: To provide adequate power to
the serverboard, be sure to connect the
24-pin ATX PWR (J24) and the 8-pin two
power connectors (JPWR1, JPWR2) to the
power supply. Failure to do so may void the
manufacturer warranty on your power supply
and serverboard.
ATX Power 24-pin Connector
Pin Denitions (JPW1)
Pin# Denition Pin # Denition
13 +3.3V +3.3V1
14 +3.3V-12V (NC) 2
15 COM COM3
16 PS_ON +5V4
17 COM COM5
18 COM +5V6
19 COM COM7
20 PWR_OKRes (NC) 8
21 +5V 5VSB9
22 +5V 10 +12V
23 +5V +12V11
24 COM 12 +3.3V
(Required)
12V 8-pin
Power Connector
Pin Denitions
Pins Denition
1 through 4 Ground
5 through 8 +12V
Produkt Specifikationer
Mærke: | Supermicro |
Kategori: | Server |
Model: | SuperServer 7048R-C1R4+ |
Har du brug for hjælp?
Hvis du har brug for hjælp til Supermicro SuperServer 7048R-C1R4+ stil et spørgsmål nedenfor, og andre brugere vil svare dig
Server Supermicro Manualer

30 Januar 2025

30 Januar 2025

11 Januar 2025

11 Januar 2025

11 Januar 2025

8 Januar 2025

28 December 2024

28 December 2024

28 December 2024

28 December 2024
Server Manualer
- Server QNAP
- Server Bosch
- Server Acer
- Server Sony
- Server HP
- Server D-Link
- Server Asus
- Server Gigabyte
- Server Toshiba
- Server Lenovo
- Server Abus
- Server Planet
- Server Black Box
- Server TRENDnet
- Server Buffalo
- Server Medion
- Server Linksys
- Server Megasat
- Server Cisco
- Server Seagate
- Server Netgear
- Server Tripp Lite
- Server Western Digital
- Server Technics
- Server Digitus
- Server Dell
- Server Fujitsu
- Server MSI
- Server NEC
- Server APC
- Server LevelOne
- Server FLIR
- Server ZyXEL
- Server Eaton
- Server ELAC
- Server Synology
- Server Hikvision
- Server Monacor
- Server AVerMedia
- Server Asustor
- Server Kramer
- Server Hanwha
- Server LaCie
- Server Naim
- Server Fantec
- Server Provision-ISR
- Server Quantum
- Server Axis
- Server ACTi
- Server Digi
- Server ATen
- Server Teo
- Server Vimar
- Server Smart-AVI
- Server Intel
- Server StarTech.com
- Server Conceptronic
- Server Rocstor
- Server IStarUSA
- Server Blackmagic Design
- Server Lindy
- Server Veritas
- Server Promise Technology
- Server Sitecom
- Server HGST
- Server AMX
- Server Intellinet
- Server Iomega
- Server Silverstone
- Server Geovision
- Server Ernitec
- Server KanexPro
- Server Gefen
- Server Moxa
- Server C2G
- Server Allnet
- Server Maxdata
- Server Matrox
- Server Valcom
- Server Freecom
- Server IoSafe
- Server Revox
- Server Luxman
- Server G-Technology
- Server Areca
- Server SEH
- Server Ibm
- Server Sonnet
- Server TAIDEN
- Server SIIG
- Server Advantech
- Server Mobotix
- Server Extron
- Server Avocent
- Server Silex
- Server Middle Atlantic
- Server In Win
- Server Sun
- Server Atlona
- Server MvixUSA
- Server Dual Bay
- Server Raidsonic
- Server EMC
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Mr. Signal
- Server Atlantis Land
- Server Lantronix
- Server NETSCOUT
- Server Origin Storage
- Server IMC Networks
Nyeste Server Manualer

9 Marts 2025

9 Marts 2025

9 Marts 2025

23 Januar 2025

23 Januar 2025

23 Januar 2025

23 Januar 2025

23 Januar 2025

19 Januar 2025

14 Januar 2025