Sygonix SY-RS2W-R2 Manual
Læs nedenfor 📖 manual på dansk for Sygonix SY-RS2W-R2 (3 sider) i kategorien Skifte. Denne guide var nyttig for 19 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/3
Intended use
In conjunction with an appropriate radio transmitter of the RS2W sys-
tems is this product capable of switching on or off a connected load
wirelessly.
The wireless switch may only be used on mains voltage (230 V/AC,
50 Hz). A maximum load of 2000 W/8.7 A (resistive load) or max.
600 W/2.6 A (inductive load) can be connected.
It is intended for indoor use only. Do not use it outdoors. Contact with
moisture, e.g. in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or mo-
dify this product. If you use the product for purposes other than those
described above, the product may be damaged. In addition, improper
use can cause hazards such as short circuiting, re, electric shock
etc. Read the instructions carefully and keep them. Make this product
available to third parties only together with its operating instructions.
This product complies with the statutory national and European requi-
rements. All company names and product names are trademarks of
their respective owners. All rights reserved.
Safety instructions
Read the operating instructions carefully and espe-
cially observe the safety information. If you do not fol-
low the safety instructions and information on proper
handling in this manual, we assume no liability for any
resulting personal injury or damage to property. Such
cases will invalidate the warranty/guarantee.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. This may
become dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight,
strong jolts, high humidity, moisture, ammable gases, vapours and
solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of
operation and protect it from any accidental use. Safe operation can
no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions
or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even
from a low height can damage the product.
• -Also observe the safety and operating instructions of any other de
vices which are connected to the product.
• This product may only be installed by a qualied technician (e.g., an
electrician) who is familiar with the relevant regulations (e.g., VDE,
German electrical wiring regulations)!
• Improper work carried out on the mains voltage endangers not only
your own life, but also the life of others!
• If you do not have the expertise required for the installation, do not
install it yourself but ask a qualied technician.
• Only use the product when it is securely installed and steady. Install
the product in a suitable ush or wall mounted box or any other
suitable housing, so that the required protection against accidental
contact is ensured.
• -Keep the product out of strong magnetic elds prevalent near ma
chines, electric motors or loudspeakers.
• Do not use this product in hospitals or medical institutions. Although
RS2W radio system transmitters only emit relatively weak radio sig-
nals, these may lead to the malfunctioning of life-support systems.
The same may also apply to other zones.
• Never touch, operate, plug in or unplug the product with damp or
wet hands. There is a risk of a life-threatening electric shock!
• -Only carry out the installation when all the mains cables to the wi
reless switch are disconnected from the mains voltage. Otherwise,
there is a risk of a life-threatening electric shock!
• An all-pole disconnection from the mains voltage (such as a surge
protector) must be provided as part of the wiring set-up.
• Never connect the product to the power supply immediately after it
has been transferred from a cold room into a warm one (e.g., during
transport). Condensation water that forms might destroy the device.
Moreover, there is danger of electric shock!
Allow the device to reach room temperature before switching it on.
Wait until the condensation has evaporated. This might take several
hours. Only after this should it be plugged in to the mains supply
and put into use.
• Never overload the product. Observe the maximum connected load
in the chapter “Technical Data”.
• Do not use the product if it is damaged. There is a risk of a life-
threatening electric shock! In this case, dispose of the product in an
environmentally correct manner.
• If it can be assumed that safe operation is no longer possible, the
device must be turned off and precautions must be taken to ensure
that it is not used unintentionally. Do not touch the wireless switch
or any device connected to it.
Latest operating instructions
Download the latest operating instructions via the
link www.conrad.com/downloads or scan the QR
code shown. Follow the instructions on the website.
Explanation of symbols
The lightning symbol inside a triangle is used when the-
re is a potential risk of personal injury, such as electric
shock.
An exclamation mark in a triangle indicates important ins-
tructions in this operating manual that absolutely have to
be observed.
The arrow symbol indicates specic tips and advice on
operation.
The product is only intended to be installed and used in
dry, indoor rooms; it must not get damp or wet.
Observe the operating instructions!
Delivery content
• RS2W radio-controlled switch
• Operating instructions
Operating instructions
RS2W radio-controlled switch
Item no. 1761777
Disconnect the wireless switch from the mains by switching off at
the appropriate circuit breaker or by pulling out the fuse. Further-
more, turn off the earth leakage circuit breaker to disconnect all the
poles of the mains supply.
• Use the product only in a temperate climate, never in a tropical
climate.
• -Consult an expert when in doubt about operation, safety or connec
tion of the device.
• -Maintenance, modications and repairs are to be performed exclu
sively by an expert or at a qualied shop.
• If you have questions which remain unanswered by these operating
instructions, contact our technical support service or other technical
personnel.
Preparations for installation
Please observe the chapter “Safety instructions”!
• To use, install the wireless switch in a suitable ush or wall mounted
box or other suitable housing.
• Install the wireless switch only, if the switch is disconnected from the
mains. First switch off all poles of the mains supply by switching off
at the circuit breaker or removing the fuse and then also switch off
the associated residual current device.
Secure it against unauthorised reconnection, e.g., with a danger
sign. Then check the mains connection for absence of voltage using
a suitable tester.
Installation and connection
Refer to the section “Preparations for Installation”.
The wireless switch makes an ideal complementary component for a
standard wall switch providing an additional wireless switching func-
tion.
This means you can keep your existing wall switch (e.g. for room
lighting) and use it with an additional radio transmitter of the RS2W
radio system.
That requires, that the ush mounted box provides sufcient space for
installing the wireless switch behind the existing wall switch.
Ensure proper protection against accidental contact when
you connect, mount and later use the wireless switch.
Otherwise, there is a risk of a life-threatening electric
shock!
• Remove the cover of your existing wall
switch and take the switch out of the ush
mounted box.
• Connect the two wires on the wireless
switch to the two switch contacts on your
wall switch (“S1”), see picture to the right.
• Connect the device to the two middle
screw terminals. The connection is the “N”
neutral conductor, the connection is “ ”
the connected output/phase/L.
• The outer two screw terminals are used
for connecting to the mains voltage ( = Neutral wire, = Phase).“N” “L”
Produkt Specifikationer
Mærke: | Sygonix |
Kategori: | Skifte |
Model: | SY-RS2W-R2 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Sygonix SY-RS2W-R2 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Skifte Sygonix Manualer
14 Juli 2024
14 Juli 2024
14 Juli 2024
14 Juli 2024
Skifte Manualer
- Skifte QNAP
- Skifte Bosch
- Skifte SilverCrest
- Skifte CyberPower
- Skifte Panasonic
- Skifte Hager
- Skifte Extech
- Skifte TP-Link
- Skifte Ei Electronics
- Skifte Philips
- Skifte IFM
- Skifte Victron Energy
- Skifte Finder
- Skifte Behringer
- Skifte HP
- Skifte Sennheiser
- Skifte Worx
- Skifte D-Link
- Skifte Asus
- Skifte Pyle
- Skifte One For All
- Skifte Yamaha
- Skifte Nedis
- Skifte Abus
- Skifte Planet
- Skifte Hama
- Skifte Belkin
- Skifte Edimax
- Skifte Theben
- Skifte Black Box
- Skifte Wago
- Skifte Clas Ohlson
- Skifte DataVideo
- Skifte TRENDnet
- Skifte Smartwares
- Skifte Trotec
- Skifte Honeywell
- Skifte Quigg
- Skifte Buffalo
- Skifte Linksys
- Skifte Cisco
- Skifte Huawei
- Skifte König
- Skifte Elro
- Skifte Steinel
- Skifte B-Tech
- Skifte Powerfix
- Skifte Alpine
- Skifte Netgear
- Skifte Totolink
- Skifte Eberle
- Skifte Grässlin
- Skifte Triax
- Skifte Tripp Lite
- Skifte Mercury
- Skifte Alcatel
- Skifte Goobay
- Skifte Digitus
- Skifte Alecto
- Skifte Flamingo
- Skifte Plantronics
- Skifte Ansmann
- Skifte Techly
- Skifte Tork
- Skifte Schneider
- Skifte Marmitek
- Skifte Basetech
- Skifte PreSonus
- Skifte Tesla
- Skifte GEV
- Skifte APC
- Skifte Kathrein
- Skifte GlobalTronics
- Skifte Elation
- Skifte Omnitronic
- Skifte Velleman
- Skifte LevelOne
- Skifte Perel
- Skifte Mercusys
- Skifte JUNG
- Skifte Vemer
- Skifte ORNO
- Skifte ZyXEL
- Skifte Tiptel
- Skifte Tenda
- Skifte Eaton
- Skifte Shimano
- Skifte Hikvision
- Skifte Monacor
- Skifte Paladin
- Skifte Brennenstuhl
- Skifte Ubiquiti Networks
- Skifte Cotech
- Skifte Aeon Labs
- Skifte Chamberlain
- Skifte GAO
- Skifte EnGenius
- Skifte AV:link
- Skifte Grandstream
- Skifte EVE
- Skifte Renkforce
- Skifte Manhattan
- Skifte SPC
- Skifte Dormakaba
- Skifte Mikrotik
- Skifte Electro Harmonix
- Skifte Aztech
- Skifte LogiLink
- Skifte Eminent
- Skifte Kramer
- Skifte Vacmaster
- Skifte Generac
- Skifte Kopp
- Skifte Provision-ISR
- Skifte Audiovox
- Skifte Fibaro
- Skifte Merlin Gerin
- Skifte Iogear
- Skifte ATen
- Skifte Vimar
- Skifte Smart-AVI
- Skifte Dahua Technology
- Skifte Chacon
- Skifte Vivolink
- Skifte Boss
- Skifte Nexa
- Skifte StarTech.com
- Skifte Doepke
- Skifte Rex
- Skifte Adder
- Skifte Toolcraft
- Skifte Crestron
- Skifte Lindy
- Skifte Russound
- Skifte Emerson
- Skifte Elektrobock
- Skifte Lancom
- Skifte Kemo
- Skifte Delta Dore
- Skifte Audac
- Skifte CYP
- Skifte AMX
- Skifte Homematic IP
- Skifte H-Tronic
- Skifte Intellinet
- Skifte Whale
- Skifte Legrand
- Skifte Shelly
- Skifte SunBriteTV
- Skifte Steren
- Skifte Heitronic
- Skifte Intelix
- Skifte Kaiser
- Skifte Equip
- Skifte PCE
- Skifte Ernitec
- Skifte Speaka
- Skifte Setti+
- Skifte BZBGear
- Skifte KanexPro
- Skifte Gefen
- Skifte RGBlink
- Skifte Profile
- Skifte Blustream
- Skifte Intermatic
- Skifte KlikaanKlikuit
- Skifte Sylvania
- Skifte Matrox
- Skifte Merten
- Skifte UPM
- Skifte Gira
- Skifte PAC
- Skifte Wentronic
- Skifte Monoprice
- Skifte IPGARD
- Skifte OSD Audio
- Skifte Unify
- Skifte Berker
- Skifte Suevia
- Skifte SIIG
- Skifte Advantech
- Skifte Micro Connect
- Skifte Extron
- Skifte Avocent
- Skifte PureLink
- Skifte Comet
- Skifte Ebode
- Skifte Robbe
- Skifte ICasa
- Skifte Cambium Networks
- Skifte Kraus & Naimer
- Skifte Noble
- Skifte Intertechno
- Skifte Extreme Networks
- Skifte Ecler
- Skifte Inverto
- Skifte Rule
- Skifte Phoenix Contact
- Skifte Seuthe
- Skifte Maclean Energy
- Skifte SmartAVI
- Skifte Cudy
- Skifte Mach Power
- Skifte SEC24
- Skifte Cooking Performance Group
- Skifte STI
- Skifte Atlona
- Skifte Adviti
- Skifte Flic
- Skifte IB Connect
- Skifte Liberty
- Skifte Hamlet
- Skifte Noark
- Skifte 2USB
- Skifte Roline
- Skifte KVM-TEC
- Skifte Epiphan
- Skifte Axing
- Skifte Juniper
- Skifte Raritan
- Skifte ConnectPro
- Skifte Atlantis Land
- Skifte Pizzato Elettrica
- Skifte Baco
- Skifte SEADA
- Skifte CSL
Nyeste Skifte Manualer
15 Oktober 2024
14 Oktober 2024
11 Oktober 2024
8 Oktober 2024
8 Oktober 2024
7 Oktober 2024
7 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024