Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 1 95 of
Meteodata 140 S weather station
Meteodata 140 S 1409207
Meteodata 140 S 24V 1409201
Meteodata 140 S GPS 1409208
Meteodata 140 S 24V GPS 1409204

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 2 95 of
Contents
1 Functional characteristics ................................................................................................ 4
1.1 ......................................................................................................... 4 Special features
1.2 rtant information ............................................................................................. 5 Impo
2 ................................................................................................................... 6 Technical data
2.1 Technical data Meteodata 140 S / 140 S GPS ........................................................ 6
2.2 Technical data Meteodata 140 S 24V / 140 S 24V GPS ........................................ 7
3 The "Meteodata 140 S V1.2" application program ......................................................... 8
3.1 Selection in the product database ........................................................................... 8
3.2 ........................................................................................... 9 Communication objects
3.2.1 Description of objects ........................................................................................... 26
3.3 ................................................................................................................ 37 Parameter
3.3.1 .................................................................................................... 37 Parameter pages
3.3.2 ........................................................................................... 38 Parameter description
4 Typical applications ......................................................................................................... 76
4.1 Simple shading control........................................................................................... 76
4.1.1 ................................................................................................................ 76 Devices:
4.1.2 .............................................................................................................. 76 Overview
4.1.3 Objects and links .................................................................................................. 77
4.1.4 ................................................................................ 78 Important parameter settings
4.2 Shading control with sun position adjustment .................................................... 79
4.2.1 ................................................................................................................ 79 Devices:
4.2.2 .............................................................................................................. 79 Overview
4.2.3 and links .................................................................................................. 79 Objects
4.2.4 ................................................................................ 80 Important parameter settings
4.3 Guttering heating ................................................................................................... 82
4.3.1 ................................................................................................................ 82 Devices:
4.3.2 .............................................................................................................. 82 Overview
4.3.3 Objects and links .................................................................................................. 82
4.3.4 ................................................................................ 83 Important parameter settings
5 Appendix .......................................................................................................................... 84
5.1 .................................................................................................. 84 Brightness sensors
5.2 Sun position adjustment ........................................................................................ 85
5.3 Azimuth and the course of the sun ....................................................................... 86
5.4 Elevation .................................................................................................................. 87
5.5 ..................................................................................................... 88 Facade direction

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 3 95 of
5.6 ................................................................................................ 89 Sun protection area
5.7 ............................................. 90 Examples for determining the sun protection area
5.7.1 Asymmetrical sun protection area ........................................................................ 91
5.7.2 Unilateral sun protection area in the left zone ...................................................... 92
5.7.3 Unilateral sun protection area in the right zone ................................................... 93
5.8 Special case: Location south of the ....................................... 94 Tropic of Cancer.
5.9 ............................................................................... 95 The Beaufort wind force scale

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 4 95 of
1 Functional characteristics
The weather station measures temperature, brightness from 3 directions and wind speed.
A rain sensor (rain / no rain) is also installed on the top of the device.
The measured values and the rain status can be sent to the bus.
The weather station has the following channel types:
• 10 universal channels for wind, rain, temperature, brightness
• 8 sun protection channels with sun position adjustment
• 4 threshold channels with per cent, EIS5 , 8- and 16-bit value)
• 6 logic channels (AND, OR, XOR)
See attachment for detailed description of the channel types.
1.1 Special features
• Adjustment of slat position according to current position of the sun.
• Sun protection area both horizontal (azimuth) and vertical (elevation) can be set exactly.
• 3 installed brightness sensors at 90° spacing.
• 2 objects for external brightness sensors.
• Shading can be temporarily interrupted via object.
• Universal channels with AND/OR linking of weather parameters.
• Threshold channels with delay with falling below and exceeding.
• Logic channels with 4 input objects + internal link that can be configured with status of the
universal and threshold channels.
Caution!
In case of installation or replacement, always use the right ETS application program!
Meteodata 140 and Meteodata 140 S require different applications!
See: www.theben.de/en/downloads_en

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 5 95 of
1.2 Important information
• Rain can only be detected when the rain sensor is sufficiently wet.
This may lead to a certain delay between the first drops of rain falling and the point that rain is
detected.
• It is possible the sensor can dry off very quickly in light rain. It is recommended not to set the
delay time below 5 minutes (standard 10 minutes) when it rains as "rain"/"no rain" are
signaled alternatively at short intervals in light rain.
• With the most sensitive setting of the rain sensor, particularly when dew suppression is
switched off, "rain" can be detected if high humidity is combined with high temperature .
Another setting must be selected if this is not required.
• As it can take several minutes to retract the sun / sight protection devices (blinds, shutters
etc.), they are not immediately protected if the wind picks up suddenly.
Therefore, take the maximum permissible wind speed specified by the manufacturer into
account when configuring the wind threshold, and set the threshold below this value to be on
the safe side.
• If the wind hits the facade from front on, an air pocket can build up where the wind speed is
significantly below the actual wind speed.
Therefore, the Meteodata 140 is only able to measure the prevailing wind speed directly at the
installation site.
This should be taken into account when setting the wind threshold for facades exposed to
strong frontal winds.
Mast installation can provide a remedy here.
• Temperature measurement: Temperatures are normally measured in the shade.
In contrast, the weather station is typically installed where the sun shines.
The measured temperature can be considerably higher than in the shade due to the effect of the
sun.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 6 95 of
2 Technical data
2.1 Technical data Meteodata 140 / 140 S S GPS
Operating voltage 110 – 230 V AC
KNX operating voltage 21-32 V DC / ≤ 3 mA
Power consumption typically 0,7W (max. 5,5 W)
Installation type Wall or mast bracket
Dimensions (H x W x D) 84 x 121 x 227 mm
Connection type KNX bus terminal
Max. cable cross-section 1.5 mm2
Ambient temperature -20 … +55 °C °C
IP rating IP 44 in accordance with EN 60529
Protection class II subject to correct installation
Measuring ranges
Brightness 1..100,000 Lux
Temperature -30..60 °C
Wind 2 - 30 m/s
Precipitation Rain/no rain

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 7 95 of
2.2 Technical data Meteodata 140 S S 24V / 140 24V GPS
Operating voltage 15 – 24 V DC (SELV)
KNX operating voltage 21-32 V DC / ≤ 3 mA
Max. power input 350 mA (at 15 V)
Max. power input when connected to
- 24 V DC
- 29 V DC
210 mA
180 mA
Power input Standby ≤ ≤ 7 mA, 15 mA with GPS
Installation type Wall or mast bracket
Dimensions (H x W x D) 84 x 121 x 227 mm
Connection type KNX bus terminal
Max. cable cross-section 1.5 mm2
Ambient temperature -20 °C… +55 °C
IP rating IP 44 in accordance with EN 60529
Protection class I subject to II correct installation
Measuring ranges
Brightness 1..100,000 Lux
Temperature -30..60 °C
Wind 2 - 30 m/s
Precipitation Rain/no rain
IMPORTANT :
Meteodata 140 S 24 V KNX 1409201
Meteodata 140 S 24 V KNX GPS 1409204

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 8 95 of
3 The "Meteodata 140 S 2V1. " application
program
3.1 Selection in the product database
Manufacturer
Theben AG
Product family
Phys. sensors
Product type
Weather stations
Programname
Meteodata 140 S V1.2
The ETS database can be found on our downloads page:
www.theben.de/en/downloads_en
Table 2
Number of communication objects:
186
Number of group addresses:
254
Number of associations:
255

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 9 95 of
3.2 Communication objects
Table 2
No. Object name
Function
Type
DPT
Flags
0 Brightness value at front
Physical value
2 byte
9.004
C R - T
1 Brightness value left
Physical value
2 byte
9.004
C R - T
2 Brightness value right
Physical value
2 byte
9.004
C R - T
3 Maximum brightness value
Physical value
2 byte
9.004
C R - T
4 Temperature value
Physical value
2 byte
9.001
C R - T
5
Wind speed (m/s)
Physical value
2 byte
9.005
C R - T
Wind speed (km/h)
2 byte
9.005
C R - T
Wind speed (Bft)
1 byte
20.014
C R - T
6 Rain sensor
Rain /
no rain
1 bit
1.001
C R - T
7
n.a.
8 Local time
receive
3 byte
10.001
C - W -
transmit
3 byte
10.001
C - - T
9 Date
transmit
3 byte
11.001
C - - T
receive
3 byte
11.001
C - W -
10 Time query
transmit
1 bit
1.001
C R - T
receive
1 bit
1.001
C - W -
11 Status time
1 = Valid time
1 bit
1.001
C - - T
12 Elevation
0° = Horizon
4 byte
14.007
C R - T
13 Azimuth
N=0°, E=90°, S=180°,
W=270°
4 byte
14.007
C R - T
14
n.a.
15 Temperature sensor status
0=OK, 1=defect
1 bit
1.001
C R - T
16
n.a.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 10 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
17
n.a.
18 External lux value 1
Receive
2 byte
9.004
C R W -
19 External lux value 2
Receive
2 byte
9.004
C R W -
20 C1.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
21 C1.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
22 C1 lock
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
23 C1 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T
24 C2.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
25 C2.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
26 C2 lock
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
27 C2 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 11 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
28 C3.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
29 C3.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
30 C3 lock
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
31 C3 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T
32 C4.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
33 C4.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
34 C4 lock
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
35 C4 brightness threshold
Request
2 byte
9.004
C R - T
enter/view
2 byte
9.004
C R W T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 12 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
36 C5.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
37 C5.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
38 C5 lock
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
39 C5 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T
40 C6.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
41 C6.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
42 C6 lock
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
43 C6 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 13 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
44 C7.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
45 C7.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
46 C7 lock
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
47 C7 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T
48 C8.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
49 C8.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
50 C8 lock
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
51 C8 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 14 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
52 C9.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
53 C9.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
54 C9 Disable
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
55 C9 Brightness threshold
enter/view
2 byte
9.004
C R W T
Request
2 byte
9.004
C R - T
56 C10.1 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
57 C10.2 Universal channel
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
58 C10 Disable
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
59 C10 Brightness threshold
Request
2 byte
9.004
C R - T
enter/view
2 byte
9.004
C R W T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 15 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
60 C11 up/down
Drives up/down
1 bit
1.008
C - - T
61
C11 Shutters
Height
1 byte
5.001
C R - T
C11 Blinds
Height
1 byte
5.001
C R - T
C11 scene
transmit
1 byte
5.001
C R - T
62 C11 lamella
Position
1 byte
5.001
C R - T
63 C11 sun control
Morning=1 /
Evening=0
1 bit
1.001
C R W -
64 C11 Interrupt shading
receive
1 bit
1.001
C R W -
65 C11 safety
Input
1 bit
1.001
C R W -
66 C11 Dawn/dusk threshold
send/receive
2 byte
9.004
C R W T
67 C11 brightness threshold
send/receive
2 byte
9.004
C R W T
68 C12 up/down
Drives up/down
1 bit
1.001
C - - T
69
C12 scene
transmit
1 byte
18.001
C R - T
C12 Blinds
Height
1 byte
5.001
C R - T
C12 Shutters
Height
1 byte
5.001
C R - T
70 C12 Slats
Position
1 byte
5.001
C R - T
71 C12 Sun control
Morning=1
/ Evening=0
1 bit
1.001
C R W -
72 C12 Interrupt shading
receive
1 bit
1.001
C R W -
73 C12 Safety
Input
1 bit
1.001
C R W -
74 C12 Dawn/dusk threshold
send/receive
2 byte
9.004
C R W T
75 C12 Brightness threshold
send/receive
2 byte
9.004
C R W T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 16 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
76 C13 Up/down
Drives up/down
1 bit
1.001
C - - T
77
C13 Blinds
Height
1 byte
5.001
C R - T
C13 Shutters
Height
1 byte
5.001
C R - T
C13 Scene
transmit
1 byte
18.001
C R - T
78 C13 Slats
Position
1 byte
5.001
C R - T
79 C13 Sun control
Morning=1 / Evening=0
1 bit
1.001
C R W -
80 C13 Interrupt shading
receive
1 bit
1.001
C R W -
81 C13 Safety
Input
1 bit
1.001
C R W -
82 C13 Dawn/dusk threshold
send/receive
2 byte
9.004
C R W T
83 C13 Brightness threshold
send/receive
2 byte
9.004
C R W T
84 C14 Threshold switch input
0..65535
2 byte
7.001
C R W -
EIS 5
2 byte
9.*
C R W -
Percent
1 byte
5.001
C R W -
0..255
1 byte
5.010
C R W -
85 C14 Disable
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
86 C14.1 Threshold switch input
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
87 C14.2 Threshold switch input
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 17 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
88 C15 Threshold switch input
0..65535
2 byte
7.001
C R W -
EIS 5
2 byte
9.*
C R W -
Percent
1 byte
5.001
C R W -
0..255
1 byte
5.010
C R W -
89 C15 Disable
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
90 C15.1 Threshold switch input
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
91 C15.2 Threshold switch input
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
92 C16 Threshold switch input
0..65535
2 byte
7.001
C R W -
EIS 5
2 byte
9.*
C R W -
Percent
1 byte
5.001
C R W -
0..255
1 byte
5.010
C R W -
93 C16 Disable
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
94 C16.1 Threshold switch input
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 19 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
100
C18 Logic module
Logic input 1 in AND/OR/XOR
gate
1 bit
1.001
C R W -
101
Logic input 2 in AND/OR/XOR
gate
1 bit
1.001
C R W -
102
Logic input 3 in AND/OR gate
1 bit
1.001
C R W -
103
Logic input 4 in AND/OR gate
1 bit
1.001
C R W -
104 C18 Logic module
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
105 C18.1 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
106 C18.2 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
107
C19 Logic module
Logic input 1 in AND/OR/XOR
gate
1 bit
1.001
C R W -
108
Logic input 2 in AND/OR/XOR
gate
1 bit
1.001
C R W -
109
Logic input 3 in AND/OR gate
1 bit
1.001
C R W -
110
Logic input 4 in AND/OR gate
1 bit
1.001
C R W -
111 C19 Logic module
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
112 C19.1 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 21 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
126 C21.1 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
127 C21.2 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
128
C22 Logic module
Logic input 1 in AND/OR/XOR
gate
1 bit
1.001
C R W -
129
Logic input 2 in AND/OR/XOR
gate
1 bit
1.001
C R W -
130
Logic input 3 in AND/OR gate
1 bit
1.001
C R W -
131
Logic input 4 in AND/OR gate
1 bit
1.001
C R W -
132 C22 Logic module
Disable = 1
1 bit
1.001
C R W -
Disable = 0
1 bit
1.001
C R W -
133 C22.1 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
134 C22.2 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 22 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
135
C23 Logic module
Logic input 1 in AND/OR/XOR
gate
1 bit
1.001
C R W -
136
Logic input 2 in AND/OR/XOR
gate
1 bit
1.001
C R W -
137
Logic input 3 in AND/OR gate
1 bit
1.001
C R W -
138
Logic input 4 in AND/OR gate
1 bit
1.001
C R W -
139 C23 Logic module
Disable = 0
1 bit
1.001
C R W -
Disable = 1
1 bit
1.001
C R W -
140 C23.1 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
141 C23.2 Logic module
Switching
1 bit
1.001
C R - T
Value
1 byte
5.010
C R - T
priority
2 bit
2.001
C R - T
142
n.a.
143
n.a.
144 UTC time
send
3 byte
10.001
C - - T
145 UTC date
send
3 byte
10.001
C - - T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 23 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
146 C24 up/down
Drives up/down
1 bit
1.008
C - - T
147
C24 Shutters
Height
1 byte
5.001
C R - T
C24 Blinds
Height
1 byte
5.001
C R - T
C24 scene
transmit
1 byte
5.001
C R - T
148 C24 lamella
Position
1 byte
5.001
C R - T
149 C24 sun control
Morning=1 / Evening=0
1 bit
1.001
C R W -
150 C24 Interrupt shading
receive
1 bit
1.001
C R W -
151 C24 safety
Input
1 bit
1.001
C R W -
152 C24 Dawn/dusk threshold
send/receive
2 byte
9.004
C R W T
153 C24 brightness threshold
send/receive
2 byte
9.004
C R W T
154 C25 up/down
Drives up/down
1 bit
1.008
C - - T
155
C25 Shutters
Height
1 byte
5.001
C R - T
C25 Blinds
Height
1 byte
5.001
C R - T
C25 scene
transmit
1 byte
5.001
C R - T
156 C25 lamella
Position
1 byte
5.001
C R - T
157 C25 sun control
Morning=1 / Evening=0
1 bit
1.001
C R W -
158 C25 Interrupt shading
receive
1 bit
1.001
C R W -
159 C25 safety
Input
1 bit
1.001
C R W -
160 C25 Dawn/dusk threshold
send/receive
2 byte
9.004
C R W T
161 C25 brightness threshold
send/receive
2 byte
9.004
C R W T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 25 95 of
Continuation:
No. Object name
Function
Type
DPT
Flags
178 C28 up/down
Drives
up/down
1 bit
1.008
C - - T
179
C28 Shutters
Height
1 byte
5.001
C R - T
C28 Blinds
Height
1 byte
5.001
C R - T
C28 scene
transmit
1 byte
5.001
C R - T
180 C28 lamella
Position
1 byte
5.001
C R - T
181 C28 sun control
Morning=1 / Evening=0
1 bit
1.001
C R W -
182 C28 Interrupt shading
receive
1 bit
1.001
C R W -
183 C28 safety
Input
1 bit
1.001
C R W -
184 C28 Dawn/dusk threshold
send/receive
2 byte
9.004
C R W T
185 C28 brightness threshold
send/receive
2 byte
9.004
C R W T

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 26 95 of
3.2.1 Description of objects
3.2.1.1 Physical values
• Object 0 "Brightness value at front"
Sends the current brightness value at front brightness sensor.
Only the value measured directly by the installed sensor is sent.
Received external brightness values are not considered.
• Object 1 "Brightness value left"
Sends the current brightness value at the left brightness sensor (looking at device from the front).
Received external brightness values are not considered.
• Object 2"Brightness value right"
Sends the current brightness value at the left brightness sensor (looking at device from the front).
Received external brightness values are not considered.
• Object 3 "Maximum brightness value"
Reports the highest measured value from objects 0, 1 and 2.
Received external brightness values are not considered.
• Object 4 "Temperature value"
Depending on the configuration, sends the current temperature value either if there is a change
and/or cyclically.
• Object 5 "Wind speed"
Depending on the configuration, sends the current wind speed if there is a change
and/or cyclically.
The unit used, i.e. m/s or km/h, Beaufort can be selected on the measured values parameter page.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 27 95 of
• Object 6 "Rain sensor"
This 1-bit object sends the current rain status – "1" for "rain" and "0" for "no rain".
Depending on how it is configured, it can be sent only when the status has changed,
after a change, or cyclically.
• Object 7
Not used.
• Object 8 "Local time"
As a transmission object:
Sends the current time in DPT 10.001 format, depending on the configuration: only on request,
cyclically or at specific times (see “Send time and date” parameter table).
As a receive object:
Used to set the time via the bus:
• Object 9 "Local date"
As a transmission object (send time):
Sends the current date in DPT 11.001 format, depending on the configuration: only on request,
cyclically or at specific times.
As a receive object (receive time):
Used to set the date via the bus:
• Object 10"Time query"
Table 2
Device version
Data orientation
without GPS module
Object sends time query to bus clock to receive the current time.
with GPS module
Object receives time query from other bus participants and initiates sending
process for time and date object.
• Object 11 "Time status"
Only with version with GPS module.
0 = No GPS time reception in the previous 24 hours. No sun position adjustment possible.
1 = Time synchronised via GPS signal and can be transmitted.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 28 95 of
• Object 12 "Elevation"
Height of the sun over the horizon.
0° corresponds to sun at lowest point on horizon (sunrise or sunset).
The actual elevation depends on the latitude and date and time.
• Object 13 "Azimuth"
Horizontal angle of the sun in all directions.
0° = North
90° = East
180° = South
270° = West
• Object 14
Not used.
• Object 15 "Temperature sensor status"
0 = Sensor OK.
1 = Error.
• Object 16
Not used.
• Object 17
Not used.
• Object 18 "External lux value 1"
Receives the brightness value of another facade from another KNX sensor (e.g. Luna 133 KNX order
no. 1339200).
• Object 19 "External lux value 2"
Receives the brightness value of another facade from another KNX sensor (e.g. Luna 133 KNX order
no. 1339200).

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 29 95 of
3.2.1.2 Universal channels C1..C10
• Object 20 "C1.1 Universal channel switch/value/priority"
This is the first output object of a universal channel.
The function of the object depends upon the selected telegram type
(see Objects parameter page, telegram type C1.1 parameter).
Table 2
Telegram type
format
Sent telegrams
Switching
DPT 1.001
(On/Off)
On/Off
priority
DPT 2.001
(priority
control)
2-bit telegram
Function
value
no priority (no control)
0
Priority OFF (control: disable, off)
2
Priority ON (control: enable, on)
3
value
DPT 5.010
Value between 0 and 255
• Object 21 "C1.2 Universal channel switch/value/priority"
This is the second output object of a universal channel.
The function of the object depends upon the selected telegram type
(see Objects parameter page, telegram type C1.2 parameter).
The telegram type can be parameterized independently of the first output object.
The same setting options are available for this purpose as for the first output object
(see table above for object 20).
The cycle time and the disabling behaviour are valid together for both objects (objects 20+21).

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 30 95 of
• Object 22 "C1 disable"
Only available if the disable function is activated.
The behaviour on setting and cancelling the disable status can be selected on the Objects parameter
page.
• Object 23 "C1 brightness threshold"
Only available if the channel is configured as brightness sensor or as link of several sensors.
This object makes it possible to change the configured brightness threshold of the channel via bus
telegram at any time.
• Objects 24..59
Objects 24 to 59 are for universal channels C2..C10 and have an identical function as with objects on
channel C1.
3.2.1.3 Sun protection channels C11..C13 and C24..C28
• Object 60 "C11 up/down"
This object is used to completely open or close the sun protection devices.
0 = raise
1 = lower
• Object 61 "C11 send shutters/blinds height, scenes"
The function of this object depends on the channel parameter controlled by sun protection channel
C11 parameter page.
Table 2
Channel controls
Object transmits
Shutter
Height telegram in %
Via scenes
Scene numbers 1..64
Blinds
Height telegram in %

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 31 95 of
• Object 62 "C11 slats"
Sends the required slat position from 0% to 100% in 1% increments to the
blinds actuator.
• Object 63 "C11 Sun control"
This object is only available if the "via object" activation of the sun control is selected on the sun
control parameter page.
A "1" on the object activates the sun control and the weather station sends the necessary height and
position telegrams to the actuator.
The sun control is deactivated with a "0", and the drives are then no longer controlled by the weather
station.
• Object 64 "C11 Interrupt shading"
This function is only effective while the sun is in defined sun protection area.
Table 2
Channel controls
Response
Shutter
Shutters move all the way up.
Via scenes
Configured scene numbers for shading break is transmitted
Blinds
Calculation of slat position
Response
Automatic via slat dimensions
Configured slat position for shading
break is sent
Allocate own values
Configured values for shading break
is transmitted.
Note: Safety has priority over shading break.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 32 95 of
• Object 65 "C11 safety"
If safety is set (= 1) then the 2 objects, C11 height and C11 slats, of the affected channel do no
transmit.
The response to the start of safety is controlled by the actuator.
On cancellation of safety (=0):
During the day: The current channel status is resent after the delay timer has finished. This means that
the actuator is sent the new settings from the weatherstation after the end of the safety phase.
During the night, the " Reaction to dusk" or "Reaction to sun control OFF " parameters apply
depending on setting (Activation of sun control object
or dawn/dusk threshold).
• Object 66 "C11 Dawn/dusk threshold"
This object makes it possible to change the configured dawn/dusk threshold of the channel via bus
telegram at any time.
• Object 67 "C11 brightness threshold"
This object makes it possible to change the configured brightness threshold of the channel via bus
telegram at any time.
• Objects 68..83, 146..185
Objects 68 to 83, 146 to 185 are for sun protection channels C12..C13, C24 to C28 and have an
identical function as with objects on channel C11.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 33 95 of
3.2.1.4 Threshold switch C14..C17
• Object 84 "C14 Threshold switch input“
Input object of channel: This object activates the set channel function.
Table 2
Type of threshold value object
Activation of channel function via
object type: Per cent (DPT 5.001)
Exceeding per cent value
Object type: Counter value 0..255 (DPT
5.010)
Any value in given numerical range
object type: Counter value 0..65535
(DPT 7.001)
Object type: EIS5 e.g. CO2, brightness
(DPT 9.xxx)
2 byte floating-point number
• Object 85 "C14 disable"
Disable object on channel
Only visible if the disable function is activated.
The action (disable with 0 or 1) can be set via parameters.
• Object 86 "C14.1 Threshold value switch, switch/value/priority"
This is the first output object of the threshold value switch.
The function of the object depends upon the selected telegram type
(see Objects parameter page, telegram type C14.1 parameter).
Table 2
Telegram type
format
Sent telegrams
Switching
DPT 1.001
(On/Off)
On/Off
priority
DPT 2.001
(priority
control)
2-bit telegram
Function
value
no priority (no control)
0
Priority OFF (control: disable, off)
2
Priority ON (control: enable, on)
3
value
DPT 5.010
Value between 0 and 255

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 34 95 of
• Object 87 "C14.2 Threshold value switch, switch/value/priority"
This is the second output object of the threshold value switch.
The function of the object depends upon the selected telegram type
(see Objects parameter page, telegram type C14.2 parameter).
The telegram type can be parameterized independently of the first output object.
The same setting options are available for this purpose as for the first output object
(see table above for object 86).
The cycle time and the disabling behaviour are valid together for both objects (objects 86+87).
• Objects 88..99
Objects 88 to 99 are for threshold value switches C15/C17 and have an identical function as with
objects on channel C14.
3.2.1.5 Logic modules C18..C23
• Object 100 "C18 Logic module, logic input 1 in AND/OR/XOR gate 1"
First input object of logic module.
• Object 101 "C18 Logic module, logic input 2 in AND/OR/XOR gate"
Second input object of logic module.
• Object 102 "C18 Logic module, logic input 3 in AND/OR/ gate"
Third input object of logic module.
Not used with XOR link.
• Object 103 "C18 Logic module, logic input 4 in AND/OR/ gate"
Fourth input object of logic module.
Not used with XOR link.

Meteodata 140 S weather station
As at: Feb- 17 (Subject to change) Page 35 95 of
• Object 104 "C18 logic module disable"
Disable object on channel
Only visible if the disable function is activated.
The action (disable with 0 or 1) can be set via parameters.
• Object 105"C18.1 Logic module, switch/ value/priority"
This is the first output object of the logic module.
The function of the object depends upon the selected telegram type
(see Objects parameter page, telegram type C18.1 parameter).
Table 2
Telegram type
format
Sent telegrams
Switching
DPT 1.001
(On/Off)
On/Off
priority
DPT 2.001
(priority
control)
2-bit telegram
Function
value
no priority (no control)
0
Priority OFF (control: disable, off)
2
Priority ON (control: enable, on)
3
value
DPT 5.010
Value between 0 and 255
• Object 106 "C18.2 Logic module, switch/value/priority"
This is the second output object of the logic module.
The function of the object depends upon the selected telegram type
(see Objects parameter page, telegram type C18.2 parameter).
The telegram type can be parameterized independently of the first output object.
The same setting options are available for this purpose as for the first output object
(see table above for object 105).
The cycle time and the disabling behaviour are valid together for both objects (objects 86+87).
• Objects 107..141
Objects 107 to 141 are for logic modules C19/C23 and have an identical function as with objects on
channel C18.
Produkt Specifikationer
Mærke: | Theben |
Kategori: | Vejrstation |
Model: | Meteodata 140 S KNX |
Har du brug for hjælp?
Hvis du har brug for hjælp til Theben Meteodata 140 S KNX stil et spørgsmål nedenfor, og andre brugere vil svare dig
Vejrstation Theben Manualer

6 August 2024

5 August 2024

3 August 2024

1 August 2024

20 Juli 2024

19 Juli 2024
Vejrstation Manualer
- Vejrstation OBH Nordica
- Vejrstation Denver
- Vejrstation Sencor
- Vejrstation Day
- Vejrstation Beurer
- Vejrstation Daikin
- Vejrstation Extech
- Vejrstation Vitek
- Vejrstation Medisana
- Vejrstation Braun
- Vejrstation Tanita
- Vejrstation Emos
- Vejrstation Daewoo
- Vejrstation Lowrance
- Vejrstation TFA
- Vejrstation Livoo
- Vejrstation Pyle
- Vejrstation Biltema
- Vejrstation Hama
- Vejrstation Muse
- Vejrstation Thomson
- Vejrstation Hyundai
- Vejrstation Clas Ohlson
- Vejrstation Optex
- Vejrstation Trevi
- Vejrstation Rocktrail
- Vejrstation Blaupunkt
- Vejrstation Honeywell
- Vejrstation Clatronic
- Vejrstation Soehnle
- Vejrstation König
- Vejrstation Elro
- Vejrstation Auriol
- Vejrstation Ventus
- Vejrstation Balance
- Vejrstation Sjöbo
- Vejrstation Bresser
- Vejrstation Davis
- Vejrstation Jacob Jensen
- Vejrstation National Geographic
- Vejrstation Alecto
- Vejrstation Krontaler
- Vejrstation GlobalTronics
- Vejrstation Rain Bird
- Vejrstation Velleman
- Vejrstation Perel
- Vejrstation JUNG
- Vejrstation Netatmo
- Vejrstation Eurochron
- Vejrstation Technoline
- Vejrstation Fluke
- Vejrstation EQ3
- Vejrstation La Crosse Technology
- Vejrstation Techno Line
- Vejrstation ADE
- Vejrstation Cotech
- Vejrstation ECG
- Vejrstation Elgato
- Vejrstation EVE
- Vejrstation Renkforce
- Vejrstation Waldbeck
- Vejrstation Brandson
- Vejrstation Orion
- Vejrstation Irox
- Vejrstation Majestic
- Vejrstation Steinberg
- Vejrstation Mebus
- Vejrstation EQ-3
- Vejrstation Vimar
- Vejrstation Oregon Scientific
- Vejrstation PeakTech
- Vejrstation Chacon
- Vejrstation Lexibook
- Vejrstation Ascot
- Vejrstation AcuRite
- Vejrstation Avidsen
- Vejrstation Chauvin Arnoux
- Vejrstation Taylor
- Vejrstation GoGen
- Vejrstation Levenhuk
- Vejrstation Minox
- Vejrstation Homematic IP
- Vejrstation ClimeMET
- Vejrstation Steren
- Vejrstation Bearware
- Vejrstation Setti+
- Vejrstation Profile
- Vejrstation Cresta
- Vejrstation Brigmton
- Vejrstation Marquant
- Vejrstation Goddess
- Vejrstation Conrad
- Vejrstation UPM
- Vejrstation Gira
- Vejrstation ELV
- Vejrstation Dexford
- Vejrstation Kemot
- Vejrstation Buienradar
- Vejrstation Saxon
- Vejrstation HomeMatic
- Vejrstation La Crosse
- Vejrstation Durabase
- Vejrstation Meade
- Vejrstation Guardo
- Vejrstation Sempre
- Vejrstation Digi-tech
- Vejrstation Unitec
- Vejrstation TFA Dostmann
- Vejrstation Greisinger
- Vejrstation Nor-tec
- Vejrstation DMV Electronics
- Vejrstation Inovalley
- Vejrstation Balance Meteo
- Vejrstation Ease Electronicz
- Vejrstation Rebel
- Vejrstation Saphir
- Vejrstation Paget Trading
- Vejrstation YONO
- Vejrstation Ytora
- Vejrstation JDC
- Vejrstation Greenure
- Vejrstation PCE Instruments
- Vejrstation Nasa
- Vejrstation Global Water
- Vejrstation ChiliTec
- Vejrstation Uzoli
- Vejrstation Xeecom ApS
- Vejrstation Marathon
- Vejrstation Ea2 LABS
- Vejrstation Hesdo
- Vejrstation Weinberger
- Vejrstation EMOS SELECT
- Vejrstation Prologue
- Vejrstation Gewiss
- Vejrstation Browin
- Vejrstation Otio
- Vejrstation Baldr
- Vejrstation Thierry Mugler
Nyeste Vejrstation Manualer

14 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025

9 Marts 2025