Side 1/4
BUTTON PLACEMENT
1
6
7
8
9
2
3
4
5
MIN/-/MIN: shows minimum t emperat ure;
adjusts clock, ala rm, and temperature a larm
va lues
C/F: changes House Code and Channel Code;
select s °C or °F
SET: activates SET function
Battery Compartment
LCD Screen
ALARM /( °C/°F): toggles bet ween °C and °F,
12 and 24 hour format , and alarm ON and OFF;
disables t emperature alarms
CHN: scrolls t hrough local a nd remot e
channels (1 to 4);
HOUR/+/MAX: shows maximum temperature;
adjusts clock, ala rm, and temperature a larm
va lues
MODE/SNOOZE: scrolls t hrough t he
clock, alarm, and (upper & lower) t emperature
alarm modes; snooze for alarm
GETTING STARTED
Remove battery cover
Set up the transmitter(s) setting up the receiverbefore
Remove battery cover
2 AA size batteries (included)
2 AA size batteries (included)
setting up the transmitter
1
*
1
The temperature will appear on the LCD screen
House code will blink for 8 seconds
2
2
3
3
4
5
6
7
8
9
10
Select House code (1-15) by pressing C/F
Press SET
Press SET
Channel code will blink for 8 seconds
Select Channel code (1-4) by pressing C/F
* If you have multiple transmitters for a single receiver,
set each transmitter to the House codesame
* If you have multiple transmitters for a single receiver,
set each transmitter to a Channel codedifferent
Min and Max Temperature
Temperature Trend
WS222 Receiver
WT440 Remote Transmitter
TEMPERATURE DISPLAY
A
B
*
The trend indicator shows the trend of the temperature
in the past half-hour interval.
Example:
The following indicates t hat the
temperat ure is rising.
Arrow Indicator
Rising Steady FallingTrend
WS222 + WT440
Wireless Weather Station
OWNER’S
MANU AL
setting up the receiver
Synchronized!!!
1
1
1
2
2
3
4
WIRELESS TRANSMISSION
Automatic Learn Function:
Manual Learn Funct ion (Remote Signal Search):
The learn funct ion start s aut omat ically and runs for approximat ely
3 minutes when batteries are first inst alled in t he receiver.
Press and hold for
3 seconds to st art .
CHN
If a new remot e transmitter is added or if signal is lost (outdoor readout
on t he receiver is blinking), the learn function must be executed again.
Within t he 3 minutes, the receiver will pick up the temperature
signal from the remot e t ransmitter and display the reading.
Unit will beep to indicat e t hat
learn function has started.
Channel symbol will blink and
unit will continue t o beep as
each remote t ransmitter is detected.
1
Within 3 minut es, the t emperature reading of the remote transmitter
will display on the receiver.
WS222 receiver
WT440 transmitter
10
Battery Cover
11
Wall Mount Bracket & Table Stand
1
1
SE T C/F
-
AA 1.5 V
+
-
AA 1
.5V
+
5
9
4
7
6
8
10
11
2
Insert batteries into compartment,
observing proper polarity
Insert batteries into compartment,
observing proper polarity; replace cover
Select temperature display in C or F by pressing C/F
° °
Replace battery cover
Congratulations on your purchase of this
weat her station set, WS222+WT440.
Please take the time to read and
understand this manual so you can begin
to enjoy the convenience and features this
product has to offer.
Main Display Unit WS222:
* clock and alarm clock function
* local temperature display
* receives and displays temperature
readings from up to 4 remote
transmitters via RF technology of 433MHz
* minimum/maximum temperature memory
* temperature trend indicator
* local/remot e temperature alarms
* day/night icon
* user-selectable C or F
* battery type: 2 x AA
° °
FEATURES
Remote Transmitter WT440:
* drip-proof design with LCD screen
* temperature display in user-selectable
C or F
* transmission range: up to 40 metres in
open area
* table stand or wall mountable
* battery type: 2 x AA
° °
SET C/F
-
AA 1.5V
+
-
AA 1.5V
+
11
10
2
11
12
3
1
12
1
1
1
8
9
67
Press in the Clock mode to display
the minimum temperature
The MIN symbol will appear.
MIN
.
To ret urn to normal temperature
display, press again.MIN
To ret urn to normal temperature
display, press again.MAX
Press in Clock mode to display
the maximum temperature.
The MAX symbol will appear.
MAX
NOTE: Min/Max readings are automat ically cleared daily at 00:00
Press t o view the minimum or maximum temperatures of the
local and remote channels 1 to 4.
CHN
1
1
LOW BATTERY INDICATION
Replace t he batteries when the Low Bat t ery Indicat ion light s up on
the LCD screen by t he local (indoor) temperat ure display.
NOTE: After replacing the bat t eries, you will need t o perform t he Setup
and Learn Function procedures again. Refer t o t he GETTING START ED
and WIRELESS TRANSMISSION sections.
Replace t he batteries when the Low Bat t ery Indicat ion light s up on
the bottom-left corner of the LCD screen on the WT440 t ransmit t er.
When the batteries are low on a transmitter, a Low Bat t ery Indication
will also light up on the L CD screen of t he WS222 receiver for t hat
particular channel.
MINIMUM
MAXIMUM
A
B
B
C
3
4
B*
A
*
*
2
2
3
3
4
4
1
1
2
1
2
3
*
4
TEMPERATURE ALARM
The is an ideal feat ure t o be used for greenhouses
and wine cellars, or any place that you require controlled temperature.
Once activated, the temperat ure alarm would sound when the room get s
too warm or t oo cold depending on your settings.
temperature alarm
You can set bot h an upper and lower temperature alarm for the local
temperat ure (main receiver unit) and/or for each of the remote
(outdoor) channels of 1 t o 4.
Scroll t o t he Upper Temperature Alarm Setting mode by pressing .
You should see the symbol and dotted lines ( ) or pre-existing
setting blink.
MODE
---
Select the desired channel, local or remote channels (1 to 4) using .CHN
Press to finish; or rMODE epeat steps for all
ot her channels if desired.
Press or key to set the desired value for the upper temperature limit.+ -
To disable t he particular alarm, press .
The dot t ed lines ( ) would reappear to indicat e
that t he alarm has been disabled.
ALARM
---
Setting the Upper Temperature Alarm
UPPER TEM PERATURE LIMIT: warmIf t he temperat ure gets t oo
and reaches t he upper t emperature limit, t he alarm would sound.
LOWER TEMPERATURE L IMIT: coldIf t he temperat ure gets t oo
and reaches t he lower temperature limit, the alarm would sound.
1
2
3
*
4
TEMPERATURE ALARM
Scroll t o t he Lower Temperat ure Alarm Set ting mode by pressing .
You should see the symbol and dotted lines ( ) or pre-existing
setting blink.
MODE
---
Select the desired channel, local or remote channels (1 to 4) using .CHN
Press to finish; or rMODE epeat steps for all
ot her channels if desired.
NOTE: In t he normal clock display, when eit her t he upper or lower
temperat ure alarm has been set for a particular channel, the or
symbol will show up solid on the LCD screen when that channel is displayed.
Press or key to set the desired value for the lower temperature limit.+ -
To disable t he particular alarm, press .
The dot t ed lines ( ) would reappear to indicat e
that t he alarm has been disabled.
ALARM
---
Setting the Lower Temperature Alarm
When the Temperature Alarm Sounds
The temperat ure alarm will sound when t he actual temperat ure has
reached (or exceeded) t he upper or lower temperature limit .
The temperat ure alarm has a distinctive tone different to that of
the clock alarm.
or symbol and t emperature limit will blink
Press ANY key t o stop the temperature alarm. Or without interruption,
the t emperat ure alarm will aut omat ically stop after one minut e.
CA
1235
4
PAGE 1
PAGE 9
PAGE 2 PAGE 3 PAGE 4
PAGE 10 PAGE 11 PAGE 12
1
3
2


Produkt Specifikationer

Mærke: UPM
Kategori: Vejrstation
Model: WT440

Har du brug for hjælp?

Hvis du har brug for hjælp til UPM WT440 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vejrstation UPM Manualer

UPM

UPM WS222 - WT440 Manual

22 August 2024
UPM

UPM WS1200 - WT440 Manual

20 August 2024
UPM

UPM W2S100 Manual

7 August 2024
UPM

UPM WS222 Manual

4 August 2024
UPM

UPM WT440H Manual

1 August 2024
UPM

UPM WT440 Manual

25 Juli 2024
UPM

UPM WS298 Manual

24 Juli 2024
UPM

UPM TC381 Manual

24 Juli 2024

Vejrstation Manualer

Nyeste Vejrstation Manualer

Davis

Davis DAV-6332 Manual

17 November 2024
Techno Line

Techno Line WS 6501 Manual

16 November 2024
Biltema

Biltema 84-0806 Manual

12 November 2024
Irox

Irox JKR-1 Manual

5 Oktober 2024
Cresta

Cresta WX580M Manual

5 Oktober 2024
JUNG

JUNG WS10R Manual

4 Oktober 2024
Cresta

Cresta DSX100 Manual

2 Oktober 2024