DESKTOP UPS
Installation & Operation
UPS1DT550-1N
UPS1DT750-1N
Product Overview
Operation Display
1. Inspection
The following items are inside the box: UPS Unit, User Manual
•Remove the UPS from its package and inspect it for damage that may have occurred during
shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.
2. Connect to Utility Power
•Connect AC power cord to utility power. Then, the UPS will start to charge inside battery. For best
result, charge the battery for 6 hours prior to initial use.
3. Plug in Equipment
•Battery back-up Outlets (5)
•Connect computer and monitor to the “Battery Backup” outlets. These outlets provide battery
backup, EMI ltering, line conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
•Surge-Protected Outlets (5)
•Connect a printer, fax machine, or scanner to the “Surge-protected” outlets. These outlets do not
provide power during power failure.
CAUTION: NEVER connect a laser printer or scanner to the battery backup sockets of UPS. The
equipment may draw signicantly power to overload the UPS
4. Turn On/O the UPS
•To turn on the UPS unit, press the power switch lightly. Then, the LED or LCD will light up. To turn
o the UPS unit, press the power switch again. Then, display will shut o.
1. LCD display or LED indicators
(Please check LED or LCD
section for the details)
2. Power Switch
3. AC input
4. Battery backup
5. Surge-protected outlets
6. USB port
7. RJ11/RJ45 in/out
UPS Mode DescriptionLCD
UPS Power ON When UPS is powered on, it will
enter this mode for 4 seconds
AC Mode
LCD information will be displayed
in the following order when LCD is
touched.
1. Output voltage
2. Input voltage
3. Load Level
4. Battery capacity
Overload in AC mode
icon will ash
When overload occurs, alarm will
beep every 0.5 seconds
Battery Mode
When batter level is low.
icon will ash.
Alarm will beep every 10 seconds
and LCD information will be
displayed in the following order
when LCD is touched
1. Output voltage
2. Input voltage
3. Load Level
4. Battery capacity
Overload in battery mode
icon will ash
When overload occurs, alarm will
beep every 0.5 seconds
*NOTE: If backlight shuts o, you may activate it by touching the screen
LED Indicators UPS1DT550-1N only
UPS1DT750-1N only
LED Alarm UPS Status
Green OFF The mains is normal and
UPS is operating normally
Yellow Sounds every 10 seconds Power failure occurs and
UPS is on battery mode
Yellow Sounds every second Low Battery
Green OFF UPS is o
Red Continuously Sounds UPS fault
LED on LED o LED Flashing
5. Install software (Optional for advanced users)
For optimal computer system protection, install UPS monitoring software to fully congure the UPS
system. Please follow steps below to download and install monitoring software.
1. Go to the website http://www.V7-world.com/downloads
2. Select ViewPower software for your operating system to download the software.
3. Follow the on-screen instructions to install the software.
Produkt Specifikationer
Mærke: | V7 |
Kategori: | Uafbrydelig strømforsyning (UPS) |
Model: | UPS1DT750-1N |
Bredde: | 158.5 mm |
Dybde: | 305 mm |
Højde: | 95 mm |
Vægt: | 3400 g |
Produktfarve: | Sort |
Batterispænding: | 12 V |
Batterikapacitet: | 5 At |
Skærmtype: | LCD |
Pakkevægt: | 3700 g |
Pakkedybde: | 376 mm |
Pakkebredde: | 142 mm |
Pakkehøjde: | 237 mm |
USB-port: | Ja |
Batteriteknologi: | Blybatterier (VRLA) |
Formfaktor: | Kompakt |
Relativ luftfugtighed ved drift (H-H): | 0 - 90 % |
Ethernet LAN-porte (RJ-45): | 1 |
Driftstemperatur (T-T): | 0 - 40 °C |
Hurtig installationsvejledning: | Ja |
Støjniveau: | 40 dB |
Udgangseffekt: | 450 W |
Certificering: | FCC, TUV, REACH |
Kabellængde: | 1.83 m |
Opladningstid for batteri: | 6 t |
Bæredygtighedscertifikater: | RoHS, ENERGY STAR |
Indgangsfrekvens: | - Hz |
Garantibevis: | Ja |
Lydalarmer: | Ja |
Strømstik: | NEMA 5-15 |
Modem-porte (RJ-11): | 1 |
AC udgange, antal: | 10 AC stikkontakt(er) |
Overspænding energivurdering: | 632 J |
Indgående driftsspænding (maks.): | - V |
Output strømkapacitet (VA): | 0.75 kVA |
Indgående driftsspænding (min.): | - V |
Udgangs driftsspænding (min.): | - V |
Udgangs driftsspænding (maks.): | - V |
UPS topologi: | Standby (offline) |
Holdetid (maks.): | 10 ms |
Beskyttelse ved overspænding: | Ja |
Bølgeform: | Sine |
Holdetid (min.): | 6 ms |
Hørbare alarmtilstande: | Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement |
Typisk backup tid ved halv styrke: | 5.5 min. |
Har du brug for hjælp?
Hvis du har brug for hjælp til V7 UPS1DT750-1N stil et spørgsmål nedenfor, og andre brugere vil svare dig
Uafbrydelig strømforsyning (UPS) V7 Manualer
27 Juni 2024
27 Juni 2024
27 Juni 2024
Uafbrydelig strømforsyning (UPS) Manualer
- Uafbrydelig strømforsyning (UPS) Ikea
- Uafbrydelig strømforsyning (UPS) Siemens
- Uafbrydelig strømforsyning (UPS) CyberPower
- Uafbrydelig strømforsyning (UPS) HP
- Uafbrydelig strømforsyning (UPS) GYS
- Uafbrydelig strømforsyning (UPS) Lenovo
- Uafbrydelig strømforsyning (UPS) Adj
- Uafbrydelig strømforsyning (UPS) Wago
- Uafbrydelig strømforsyning (UPS) Gembird
- Uafbrydelig strømforsyning (UPS) Tripp Lite
- Uafbrydelig strømforsyning (UPS) Digitus
- Uafbrydelig strømforsyning (UPS) Aiptek
- Uafbrydelig strømforsyning (UPS) EnerGenie
- Uafbrydelig strømforsyning (UPS) Voltcraft
- Uafbrydelig strømforsyning (UPS) APC
- Uafbrydelig strømforsyning (UPS) LevelOne
- Uafbrydelig strømforsyning (UPS) Eaton
- Uafbrydelig strømforsyning (UPS) BlueWalker
- Uafbrydelig strømforsyning (UPS) Steren
- Uafbrydelig strømforsyning (UPS) Salicru
- Uafbrydelig strømforsyning (UPS) Approx
Nyeste Uafbrydelig strømforsyning (UPS) Manualer
15 November 2024
8 November 2024
8 November 2024
22 Oktober 2024
22 Oktober 2024
21 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
2 Oktober 2024