Regolatore 230 V~ 50/60 Hz per lampade ad incandescenza 40-1000 W, tra-
sformatori ferromagnetici 40-1000 VA, funzione MASTER per 01862, fusibile
di protezione, tecnologia MOSFET+TRIAC, installazione su guida DIN (60715
TH35), occupa 4 moduli da 17,5 mm
Il dispositivo riceve i comandi direttamente dal bus ed è in grado di comandare direttamente il
carico. Può comandare inoltre fino a 4 regolatori SLAVE 01862.
CARATTERISTICHE.
Tensione nominale di alimentazione: BUS 29 V
Assorbimento: 10 mA
Potenza dissipata: 7 W
Morsetti: carico, L fase, bus TP
4 moduli da 17,5 mm
Memorizzazione, allo spegnimento del carico, della regolazione impostata (salvo interruzione di rete)
Accensione graduale (soft start): garantisce un passaggio graduale dallo stato di spento a
quello di massima luminosità; in questo modo, contribuisce all’aumento della vita della lam-
pada riducendo lo stress subìto dal filamento durante l’accensione a freddo ed evita l’effetto
abbagliante per le persone
Spegnimento graduale (soft end): garantisce un passaggio graduale dallo stato di massima
luminosità a quello di spento
Possibilità di impostare la ricerca del massimo
Fusibile ad alto potere di interruzione tipo F5H250V incorporato
Va utilizzato in luoghi asciutti e non polverosi ad una temperatura compresa tra -5 °C e + 45
°C (da interno).
CARICHI COMANDABILI
Lampade a incadescenza e alogene: 40-1000 W 50/60 Hz.
• Trasformatori ferromagnetici per lampade alogene in bassissima tensione: 40-1000 VA 50/60 Hz.
ATTENZIONE: I dati di potenza sopra riportati sono garantiti ad una temperatura ambiente
di 25°C; ad ogni incremento di 1C dI tale temperatura, il valore di potenza deve essere
ridotto del 10%.
Dichiarazioni supplementari a cura del costruttore
Non adatti al comando di motori (es. agitatori d’aria, aspiratori).
CONFIGURAZIONE.
PER LE OPERAZIONI DI INSTALLAZIONE E CONFIGURAZIONE, VEDERE IL MANUALE
ISTRUZIONI DEL SISTEMA By-me ALLEGATO ALLA CENTRALE DI CONTROLLO.
Blocchi funzionali: 1; il blocco può appartenere al massimo a 4 gruppi.
Selezione del blocco funzionale (configurazione): durante la creazione dei gruppi, quando la
centrale richiede di premere il pulsante dei dispositivi:
- premere il pulsante, si accende il led rosso;
- a led rosso acceso, la centrale configura il blocco funzionale; al termine dell’operazione il led
rosso si spegne.
PARAMETRI.
Velocità di regolazione: bassa, media o alta.
Led sempre spento o acceso solo a regolatore attivo.
Segnalazione LED regolatore:
- arancione acceso: normale funzionamento;
- spento: assenza tensione di alimentazione, collegamento errato oppure carico interrotto
(controllare il fusibile ed eventualmente sostituirlo con un altro dello stesso tipo).
Segnalazione LED di configurazione:
- acceso rosso: fase di configurazione;
- acceso verde: a seconda della configurazione e soltanto con centrali 20510-16950 -14510;
- spento: soltanto in presenza di centrali 20550+01960, 01950, 01951, 01952, 01956 e 01958.
Parametri di default: attuatore regolatore con velocità di regolazione media, led di configurazione
sempre spento.
SCENARI.
L’attuatore pappartenere fino a 4 scenari diversi e, per ogni scenario, memorizzare lo stato
da richiamare all’attivazione dello scenario stesso.
REGOLE DI INSTALLAZIONE.
L’installazione deve essere effettuata con l’osservanza delle disposizioni regolanti l’installazio-
ne del materiale elettrico in vigore nel paese dove i prodotti sono installati.
Lunghezza massima tra regolatore MASTER e SLAVE: 100 m.
La potenza nominale non deve essere mai superata.
Sovraccarichi, archi elettrici e cortocircuiti danneggiano irreparabilmente il regolatore. Prima
dell’installazione eseguire un’attenta verifica del circuito eliminando le eventuali cause sopra esposte.
Il regolatore non è provvisto di interruzione meccanica nel circuito principale e non fornisce
quindi separazione galvanica. Il circuito sul lato carico deve essere considerato sempre
in tensione.
Per ulteriori istruzioni si veda il manuale allegato alla centrale di controllo.
230 V~ 50/60 Hz dimmer for incandescent lamps 40-1000 W, ferromag-
netic transformers 40-1000 VA, MASTER function for 01862, protection fuse,
MOSFET+TRIAC technology, installation on DIN rail (60715 TH35), occupies
4 modules of 17.5 mm.
The device receives commands directly from the BUS and is able to control the load directly.
It can moreover control up to 4 SLAVE dimmers 01862.
CHARACTERISTICS.
Rated supply voltage: BUS 29 V
Input: 10 mA
Power dissipation: 7 W
Terminals: load, L phase, TP bus
4 modules of 17.5 mm
Lighting level is saved when turned off (unless there is a blackout)
Soft start: ensures gradual lighting from zero to maximum brightness. This way the life of a
lamp is increased by reducing stress on the filament and prevents light flash
Soft end: ensures a gradual passage from light to dark
Can set search for maximum
Fuse with high breaking capacity type F5H250V incorporated
It should be used in dry, dust-free places at a temperature between -5 °C and +45 °C
(indoor use).
CONTROLLABLE LOADS
Incandescent and halogen lamps: 40-1000 W 50/60 Hz.
Ferromagnetic transformers for low-voltage halogen lamps: 40-1000 VA 230 V~ 50/60 Hz.
WARNING: The above power data are guaranteed at an ambient temperature of 25°C; for
each increase of 10°C in the ambient temperature, the power value must be reduced by 10%.
Constructor further information
Not suitable to control motors (e.g. ventialtors and exhaust fans).
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE THE By-me
SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE CONTROL UNIT.
Functional blocks: 1; the block can belong to at most 4 groups.
Selecting the functional block (configuration): during group creation, when the control unit
requires pressing the device button:
- press the button, the red LED will light up;
- with the red LED on, the control unit will configure the functional block; at the end of this
operation the red LED will go out.
PARAMETERS.
Adjustment speed: low, medium or high;
LED always off or on only with dimmer on.
Dimmer LED indicator:
- on orange: normal operation;
- off: no supply voltage, incorrect connection or broken load (check the fuse and if necessary
replace it with another one of the same type).
Configuration LED indicator:
- on red: configuration phase;
- on green: depending on the configuration and only with control panels 20510-16950 -14510;
- off: only with control panels 20550+01960, 01950, 01951, 01952, 01956 and 01958.
Default parameters: dimmer actuator with medium adjustment speed, configuration LED
always off.
SCENARIOS.
The actuator can belong to up to 4 different scenarios and, for each scenario, save the status to
retrieve when activating the scenario.
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electrical systems in
the country where the products are installed.
• Maximum length of cables connecting MASTER dimmer and SLAVE dimmer: 100 metres.
The rated power level should never be exceeded.
Overloading, power surges and short-circuits may irreparably damage dimmers. Before
installation check the circuit carefully and eliminate any of the above causes.
The dimmer does not have a mechanical circuit breaker in the main circuit and so is not
galvanically separated. The circuit load should be considered always under voltage.
For further instructions, please see the manual attached to the control panel.


Produkt Specifikationer

Mærke: Vimar
Kategori: Lysdæmper
Model: 01861

Har du brug for hjælp?

Hvis du har brug for hjælp til Vimar 01861 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Lysdæmper Vimar Manualer

Vimar

Vimar 14147.SL Manual

20 August 2024
Vimar

Vimar 09147.CM Manual

19 August 2024
Vimar

Vimar 09153.CM Manual

18 August 2024
Vimar

Vimar 14099 Manual

18 August 2024
Vimar

Vimar 14135.1 Manual

17 August 2024
Vimar

Vimar 14139.SL Manual

16 August 2024
Vimar

Vimar 14149.SL Manual

16 August 2024
Vimar

Vimar 20142.B Manual

16 August 2024
Vimar

Vimar 20139.120.B Manual

15 August 2024

Lysdæmper Manualer

Nyeste Lysdæmper Manualer

Elro

Elro HE805S Manual

21 September 2024
ABB

ABB 2210UJ-214 Manual

14 September 2024
DiO

DiO 54767 Manual

12 September 2024
Ltech

Ltech CHLSC52 Manual

5 September 2024
Ltech

Ltech CHLSC39TX Manual

5 September 2024
Ltech

Ltech CHLSC41TX Manual

5 September 2024
Ltech

Ltech CHLSC20TX Manual

5 September 2024
Ltech

Ltech CHLSC50 Manual

5 September 2024
Ltech

Ltech CHLSC51 Manual

5 September 2024
Ltech

Ltech CHLSC42TX Manual

5 September 2024