Operating temperature C - 50°C (or 32°F – 122°F)
Comfort / Reduction mode
setting temperature range 5°C – 35°C (or 41°F - 95°F)
Daily clock programmable 24H with 15 minutes step
Weekly clock programmable 7 days with 1 hour step
Regulation
characteristics Proportional band 2°K for 10min cycle
Electrical Protection Class II - IP30
Power Supply
Battery operated life
2 x AA LR06 1.5V
> 1 year (For Alkaline type)
Output Relay output => 1RT Free contact (8(3)A 250Vac )
PPL IMP 1083B
USER GUIDE GB SELECT MODE
Thermostat “Chrono Battery” Electronic Daily BT 050
Thermostat “Chrono Battery” Electronic Weekly BT 051
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
- Electronic thermostat with mechanical clock.
- Possibility to set day and night temperature.
- Daily or Weekly program.
- 3 positions switch : Clock – Reduction Mode – Comfort
- Relay output (free contact)
- Clock mode: The system follows the temperature set by the
and knobs, according to the program clock.
- Reduction mode: The system follows the temperature set
by the knob.
- Comfort mode: The system follows the temperature set
by the knob.
Reduction temperature
setting.
Programmable
clock.
Comfort temperature
setting.
Select
mode.
Batteries
compartment
PROGRAMMABLE CLOC
K
Daily programmable clock Weekly programmable clock