Winix L60 Manual


Læs nedenfor 📖 manual på dansk for Winix L60 (2 sider) i kategorien Luftfugter. Denne guide var nyttig for 12 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
1
4
2
5
3
6
PACKAGE CONTENTS
Unit User Manual
L60 / L61
rThe Pod uct warrranty is printed on the back of this gu ide.
r rThis P oduct is manufactu ed for use onl y in USA / CA.
r y.This P oduct is suitable for 120 V onl
Model Name:
:
Ultra sonic Humi difier
Mist Nozzle
Water
Tank Cap
Mist Rotary
Switch
Water Tank
Bottom
Water Level Sensor
Air Outlet
Ultrasonic Transducer
WHERE TO USE
MODEL PART DIAGRAM
12~18 in
12~18 in
Position the humidifier at least 12 in / 30 cm away from walls and
appliances to prevent them from getting wet.
Place the humidifier on a table or desk. Do not place it directly on
the floor or carpet.
Do not place the unit against walls or objects or in areas with poor
air circulation. Doing so may result in improper readings produced
by the built-in humidity sensor.
If used in a closed (sealed) room without proper ventilation and no
heat exchange with outside air, water collection can occur when
the humidified air touches the cold surface. In such cases, it is
recommended to use in a lower mist level.
01. Power & Mist Rotary Switch Button
Turn the control dial clockwise.
Power and mist level can be set by dialing the knob control, freely adjust the mist for quieter operation.
02. Empty Tank Alarm
If there is not enough water, the unit will stop and the red LED indicator will continue to blink at the same time.
03. Night Mood Light
Press the Night Mood Light button once to turn on the Night Mood Light. The light at the bottom of the water
tank will turn on, illuminating the tank.
The brightness of the light can be switched OFF > Blue > Green > Amber > OFF.
CONTROL PANEL
Capacity
0.6 Gallon - 2.2 Liters
Max. 30 Hours Runtime
Based on the natural humidity level in your home, the temperature of water you use, and the mist-level setting
you choose, you may experience longer or shorter runtimes.
Adjustable Mist Level
Mist adjusts from the lowest output to highest ouput.
The corresponding mist level will be lit on the Mist Rotary Switch Button.
Whisper-Quiet Operation
Noise level below 28 dB allows you to sleep easily in a comfortable and quiet environment.
Night Mood Light
A useful light feature is included with the option of an independent Night Mood Light or touch button controls.
Auto Shut Off Protection
When the tank is empty, the unit will shut off automatically.
How do you add essential oils?
1. Essential oil can only be added to the base.
2. Always add around 100 ml water to the base before adding essential oil.
MAINTENANCE AND CLEANING
ULTRASONIC WARM & COOL MIST HUMIDIFICATION
Read all instructions before installation and use
Always place humidifier on a firm, flat surface.
A waterproof mat or pad is recommended for under
the humidifier. A finished floor may be damaged by
water or moisture exposure.
Do not reach for a unit that has fallen into water.
Unplug it immediately.
Always unplug the unit from the electrical outlet
immediately after using and before cleaning.
Do not place or store the unit where it can fall or be
pulled into a tub or sink.
Wash the nozzle, cover separately, and let tank dry in
the shade
Clean tank at least once or twice a week using
clean water.
Naturally occurring stains inside the tank can be
cleaned using a soft cloth.
Do not use chemicals such as bleach, abrasive, etc.
to clean.
Cleaning the ultrasonic transducer
Clean the ultrasonic module of
the humidifier at least once or
twice a week.
Tilt it in the direction of the air
hinge when disposing of
the water in the main body.
Do not allow water into this
opening.
Never touch the transducer / ultrasonic membrane
with your fingers; the natural oils in skin can
damage the surface.
Never clean the ultrasonic membrane by scraping
with a hard object. Scratching the surface of the
vibrator with a sharp object may cause the Mist
Output to weaken or cause failure.
Never submerge the base in water or any other liquid.
In general, if the user touches the transducer/
ultrasonic membrane with your fingers, the natural
oil and cosmetics in your skin can damage the
surface, resulting in irregular mist output.
In order to have the unit run properly after this
occurs, you need to:
1. Wash the water tank and the base 2 ~ 3 times and
then restart the unit. In case the unit is not washed,
the unit will operate normally after running for
30 min ~ 1 hour on continuous mode.
2. If the water is not enough, the mist may not be
generated properly. (This may be a defect in the air
hinge or water valve).
There should be at least
30 mm of water in the base after removing the
water tanks.
Guide bracket silencer
It is best to wash off with clean running water.
Dry and refit.
Deep cleaning (with vinegar)
Before and after storing the humidifier for a long
period of time, dry the water in the Mist Output
completely and wipe clean.
Clean the tank, reservoir, tank cap, and the
transducer/ultrasonic membrane with a 10:1
mixture of water and white vinegar.
Fill the tank with diluted vinegar water to the
maximum level.
Put about 400 mL of mixed water into the main
body.
Fill the water tank and main body with water and
leave for 30 to 60 minutes.
Pour mixed water and rinse with clean tap water
2 ~ 3 times.
Dry the parts in a well-shaded place.
Please reassemble the dried product.
INITIAL OPERATION
1. Position the unit on a flat and hard surface.
Remove the upper cover and water tank from
the base.
2. Pour around room temperature water into the
base.
3. Add 6 - 7 drops of essential oil into the base as
shown. You may increase the amount of essential
oil to your liking.
4. Place the water tank back on and fill it with room
temperature water, not exceeding the MAX line.
If you don’t use essential oil, please ignore steps 2 - 4.
5. Place the cover back on the water tank and make
sure it is sitting well.
6. Plug in and turn on the appliance. Always add
the water into the unit before connecting to power.
This prouct is intended for household use only.
Never cover the unit while it is operating.
Always keep the cord away from high temperature and
fire.
Perform regular maintenance on the ultrasonic
membrane.
Never use detergent to clean the ultrasonic membrane.
Do not attempt to adjust or repair the unit. Servicing must
be performed by a professional or qualified personnel.
Stop using the unit if there is an unusual noise or smell.
Unplug the unit when not in use for a long period of time.
Do not touch the water or any parts of the unit that are
covered by water while the unit is on or plugged in.
Never operate without water in the tank.
Only use water in the tank.
Never use any additives in the water.
Keep this unit out of the reach of children. Do not allow
children to use this unit without supervision.
Do not use outdoors. For indoor use only.
W A R N I N G
Follow the instructions in this manual to reduce
the risk of electric shock, short circuit, and/or fire.
If the power cord is damaged, it must be replaced
with a special cord. Reassembly is available from the
manufacturer or its service agent.
This appliance is not intended for use by a person
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge
about this unit, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
This unit is not intended to be used to preserve
documents or for art conservation.
Do not pull on the power cord when unplugging
the unit.
Do not tie or knot the power cord while unit is in
operation.
If the unit becomes submerged in water, unplug it
and contact customer service.
Do not unplug or move the unit while in operation.
Do not plug additional appliances into the same
outlet or power supply.
Do not touch the plug with wet hands.
Unplug the unit when not in operation for extended
periods of time.
Do not place around heating elements.
Do not use around mist or fumes from industrial oil
or around large quantities of metallic dust.
The cord can become damaged by forcefully
bending, pulling, twisting, bundling, pinching or
placing heavy objects on it.
Do not install in any sort of motor or transport
vehicle (trucks, boats, ships, etc.).
Do not place in an area with excessive amounts of
noxious gases.
Do not place near any flammable materials
(aerosols, fuel, gases, etc.).
Do not have the unit facing into wind or drafts.
Do not place below any electrical outlet.
Do not place in excessively humid areas where
the unit may become wet.
To reduce the risk of fire or electric shock,
do not use this appliance with any solid-state
speed control device.
SAFETY & CAUTIONS
1 2
CAUTION: Before filling the tank with water, turn the power off and unplug the unit from the outlet.
LUNA0.5_EN.indd 1
LUNA0.5_EN.indd 1
LUNA0.5_EN.indd 1
LUNA0.5_EN.indd 1LUNA0.5_EN.indd 1 2020-10-22  5:51:13
2020-10-22  5:51:13
2020-10-22  5:51:13
2020-10-22  5:51:132020-10-22  5:51:13


Produkt Specifikationer

Mærke: Winix
Kategori: Luftfugter
Model: L60

Har du brug for hjælp?

Hvis du har brug for hjælp til Winix L60 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Luftfugter Winix Manualer

Winix

Winix L60 Manual

31 August 2024
Winix

Winix L100 Manual

12 Juli 2024

Luftfugter Manualer

Nyeste Luftfugter Manualer

Eldom

Eldom Amar NU50 Manual

16 November 2024
Medescan

Medescan WSV0124 Manual

6 November 2024
Scarlett

Scarlett SC-985 Manual

15 Oktober 2024
Master

Master DHA 250 Manual

10 Oktober 2024
Philips

Philips HU1509 Manual

7 Oktober 2024
Philips

Philips HU5710 Manual

7 Oktober 2024
Trotec

Trotec TTR 300 Manual

3 Oktober 2024