BPM120 - Blood Pressure Monitor
MEM SET
2
3
English Manual
Manuel d’utilisation en français
Gebrauchsanleitung auf Deutsch
Manual de Instrucciones en Español
Manuale ’istruzioni In Italianod
Instrukcja obsługi. Polski
5
31
53
75
97
119
Contents
4
5
English Manual
6
Contents
INTRODUCTION 7
Safety information
Product symbols
Cautions
LCD display
Monitor components
Box contents
BEFORE YOU START 11
The choice of power supply
Installing and replacing the batteries
Setting date and time
Select the User
TAKING MEASUREMENTS 15
Tie the cuff
Start a measurement
MANAGING THE RECORDS 17
Recall the records
Delete the records
INFORMATION FOR USER 19
Tips for accurate measurements
Maintenance
ABOUT BLOOD PRESSURE 21
What are systolic pressure and diastolic pressure?
What is the standard blood pressure classification?
Irregular Heartbeat Detector
Why does my blood pressure fluctuate throughout the day?
Why do I get a different blood pressure at home compared to the hospital?
Is the result the same if measuring on the right arm?
TROUBLESHOOTING 24
SPECIFICATIONS 25
CONTACT INFORMATION 26
COMPLIED EUROPEAN STANDARDS LIST 26
AUTHORISED COMPONENTS 27
EMC GUIDANCE 27
WARRANTY 28
7
Safety Information
Thank you for selecting Duronic BPM120 arm blood pressure monitor. The monitor
features blood pressure measurement, pulse rate measurement and auto-saves the
results recorded. This model provides you with at least two years of reliable service.
Readings taken by the blood pressure monitor are equivalent to those obtained
by a trained observer using the cuff and stethoscope auscultation method. This
instruction manual contains important safety and care information, and provides
step-by-step instruction for using the product. Please read the manual thoroughly
before using the product.
BPM120 Features:
- 60x41mm Digital LCD display
- Holds a maximum of 60 records
- Uses inflating measuring technology
Product Symbols
The symbols shown below may appear in the user manual, labelling or other
components. They are the requirement of standard and using.
THE OPERATION GUIDE
MUST BE READ Type BF Applied Parts
CE Mark: Conforms to essential
requirements of the Medical
Device Directive 93/42/EEC.
DISPOSAL: Do not dispose this
product as unsorted municipal
waste. Collection of such waste
separately for special treatment
is necessary.
Manufacturer Direct Current
Serial Number Authorized Representative in the
European Community
Manufacture Date
RECYCLE: Electrical waste products
should not be disposed of with
household waste. Please recycle
where facilities exist. Check with your
local authority or retailer for recycling
advice.
The Green Dot is the license symbol
of a European network of industry-
funded systems for recycling the
packaging materials of consumer
goods.
SN
EC REP
8
Cautions
This device is intended for adult use only. This device is intended for non-invasive measuring
and monitoring of arterial blood pressure. It is not intended for use on any extremities other
than the arm or for any functions other than obtaining a blood pressure measurement. Do not
confuse self-monitoring with self-diagnosis. This machine allows you to monitor your blood
pressure. Do not begin or end medical treatment without asking a doctor for treatment advice.
If you are taking medication, consult your doctor to determine the most appropriate time of day
to measure your blood pressure. Never change a prescribed medication without consulting
your doctor. When the device is used to measure patients, who have common arrhythmias
such as atrial or ventricular premature beats or atrial fibrillation, the best result may occur with
deviation. Please consult your doctor about the result.
If the cuff pressure exceeds 40 kPa (300 mmHg), the unit will automatically deflate. Should the
cuff not deflate when pressure exceeds 40 kPa (300mmHg), detach the cuff from the arm and
press the START /STOP button to stop inflation.
The equipment is not AP/APG equipment and is not suitable for use in the presence of a
flammable anesthetic mixture with air of with oxygen or nitrous oxide. The operator shall not
touch output of batteries and the patient simultaneously. To avoid measurement errors, please
avoid exposing the machine to strong electromagnetic field radiated interference signal or
electrical fast transient/burst signal.
The user must check that the equipment functions safely and see that it is in proper working
condition before being used. This device is contraindicated for any female who may be
suspected of, or is pregnant. Besides providing inaccurate readings, the effects of this device
on the fetus are unknown.
Manufacturer will make available on request circuit diagrams, component parts list etc.
This unit is not suitable for continuous monitoring during medical emergencies or operations.
Otherwise, the patient’s arm and fingers will become numb, swollen and even purple due to a
lack of blood.
Please use the device under the environment which was provided in the user manual,
otherwise, the performance and lifetime of the device will be impacted and reduced.
During use, the patient will be in contact with the cuff. The materials of the cuff have been
tested and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It
will not cause any potential sensization or irritation reaction.
Please use the accessories and detachable parts specified/authorised by Duronic. Otherwise,
it may cause damage to the unit or danger to the user/patients.
The device should not need to be calibrated within the two years of reliable service. When
disposing of the accessories, detachable parts, or any of the medical equipment, do so
according to the local refuse/ recycling guidelines.
If you have any problems with this device, such as setting up, maintaining or using it, please
contact the Customer Care Team at Duronic. Do not open or repair the device by yourself.
When cleaning, use the soft cloth to clean the whole unit. Don’t use any abrasive or volatile
cleaners.
9
Systolic blood pressure High blood pressure
Diastolic blood pressure Low blood pressure
Pulse display Pulse in beats per minute
Average value The average value of blood pressure
Memory Indicates memory mode and memory group
Motion indicator Motion may result in an inaccurate
measurement
mmHg Measurement Unit of the blood pressure
(1mmHg=0.133kPa)
Low battery Batteries are low and need to be replaced
Irregular heartbeat Blood pressure monitor is detecting an
irregular heartbeat during measurement.
Blood pressure
level indicator Indicate the blood pressure level
Current Time Year/Month/Day, Hour/Minute
Heartbeat Blood pressure monitor is detecting a
heartbeat during measurement.
User 1 Start measurement for User 1
User 2 Start measurement for User 2
LCD Display
SYMBOL DESCRIPTION EXPLANATION
mmHg
11
Installing and Replacing the Batteries
Choice of Power Supply
1. Battery powered mode: 6VDC 4*AAA batteries
2. AC adaptor powered mode: 5V 1A (not included)
Corresponding AC adapters with USB cables are widely
available.
If in doubt, contact Duronic for advice.
Caution: In order to get the best effect and protect your monitor,
please use the right battery and special power adapter
Do not use different types of batteries together.
.
Caution:
Remove batteries if the device is not likely to be used for some time.
Old batteries are harmful to the environment - do not dispose of with
other daily rubbish. Remove the old batteries from the device and
follow your local recycling guidelines. Do not dispose of batteries in
fire - batteries may explode or leak.
1. Slide off the battery cover.
2. Install the batteries by matching the correct
polarity, as shown.
3. Replace the cover.
Replace the batteries whenever the below
happens:
- The symbol shows
- The display dims
- The display does not light up
AC adaptor
MEM SET
13
5. Repeat step 2 and 3 to set the [TIME FORMAT] between 12h and 24h.
6. Repeat steps 2 and 3 to also set the [HOUR] and [MINUTE].
6. After the [MINUTE] is set, the screen
will show “DONE”, it will show you the
date/time you have set and then it will turn
off automatically.
15
Tie the Cuff
Remove all jewellery such as watches, bracelets from your left arm. If your doctor
has diagnosed you with poor circulation in your left arm, use your right arm instead.
1. Roll or push up your sleeve to expose
the skin. Make sure your sleeve is not too
tight.
2. Wrap the cuff around your upper arm,
then position the tube off-centre toward
the inner side of arm, in-line with the little
finger.
3. The cuff should be snug but not too
tight. You should be able to insert one
finger between the
cuff and your arm.
4. Sit comfortably with your left arm resting
on a flat surface. Place your elbow on a
table so that the cuff is at the same level
as your heart. Turn your palm upwards. Sit
upright and take 5-6 deep breaths.
2~3cm
.
.
Tips for Accurate Measurements
- Rest for 5 minutes before measuring.
- Wait at least 3 minutes between measurements. This allows your blood circulation
to recover.
- For a meaningful comparison, try to measure under similar conditions. For
example, take daily measurements at approximately the same time, on the same
arm, or as directed by a doctor.
- Sit comfortably. Do not cross your legs and keep your feet flat on the ground. Keep
your back against the backrest of the chair.
16
Start a Measurement
1. When the monitor is off, press the “START/STOP” button to
turn on the monitor. It will start and finish the whole measurement
automatically.
LCD Display when switched on.
Inflating and measuring
automatically.
Displays and saves the results
automatically.
Adjusts the zero automatically.
2. If you need to turn off the monitor during the measurement
process, press the “START/STOP” button to turn it off, otherwise
it will turn off automatically within 1 minute when it completes the
measurement.
STAR T
STOP
STAR T
STOP
17
Recall the Records
1. When the monitor is off, press the “MEM” button to show the most
recent record.
2. Press the “MEM” or “SET”
buttons to move through the
historic records to find the
record you want.
The record will be shown in this order: first showing the record number, followed by
the date and then the time.
Caution: The most recent record (1) is shown first. Each new
measurement is assigned to the first (1) record. All other records
are pushed back one digit (e.g., 2 becomes 3, and so on), and the
last record (60) is dropped from the list.
The corresponding
time is 10:38.
The corresponding
date is 2019 year
July 1st.
The current No. is No. 1
three records in total.
UP
MEM
MEM
DOWN
SET
20
Maintenance
In order to get the best performance, please follow the below instructions.
Store in a dry place and avoid direct
sunlight.
Avoid the monitor touching water.
If the machine gets wet, dry immediately
afterwards.
Avoid dusty environments and unstable
temperatures.
Avoid intense shaking and collision.
Use a wet (well wrung) cloth to remove
any dirt.
Do not clean the cuff with water and
never immerse the cuff in water or any
other liquid.
MEM
MEM
MEM
SET
SET
MEM SET
SET
25
Power supply
Battery powered mode:
6VDC 4*AAA batteries
AC adaptor powered mode: 5V 1A
Can be supplied by AC adaptor model
(Not Included)
Display mode Digital LCD V.A.60*41mm
Measurement mode Oscillographic testing mode
Measurement range
Rated cuff Pressure 0mmHg~299mmHg(0kPa
39.9kPa) SYS: Measurement pressure:
60mmHg~230mmHg (8.0kPa~30.7kPa) DIA:
40mmHg~130mmHg (5.3kPa~17.3kPa)
Pulse value: (40~199) beat/minute
Accuracy
Pressure:
5℃~40℃within±0.4kPa(3mmHg)
pulse value:±5%
Normal working condition
Temperature: 5℃ 40℃ Relative+ to + .
humidity range of 15% to 90%. Atmospheric
pressure: 700 hPa to 1060hPa
Storage & transportation
condition
Temperature: -20℃ to 60
Relative humidity: ≤93%
Atmospheric pressure: 50kPa to 106kPa
Measurement perimeter of
the upper arm
About 22cm~42cm
Weight Approx. g(Excluding the dry cells)162
External dimensions Approx. 1 mm93x 30x32,5
Attachment 4*AAA batteries,user manual
Mode of operation Continuous operation
Degree of protection Type BF applied part
Protection against ingress of
water
IP21
Software Version A01
Specications


Produkt Specifikationer

Mærke: Duronic
Kategori: Blodtryksmåler
Model: BPM120

Har du brug for hjælp?

Hvis du har brug for hjælp til Duronic BPM120 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Blodtryksmåler Duronic Manualer

Duronic

Duronic BPM120 Manual

27 August 2024
Duronic

Duronic BPM450 Manual

21 August 2024
Duronic

Duronic BPM490 Manual

14 August 2024
Duronic

Duronic BPM150 Manual

11 August 2024
Duronic

Duronic BPM400 Manual

4 August 2024
Duronic

Duronic BPM080 Manual

1 August 2024

Blodtryksmåler Manualer

Nyeste Blodtryksmåler Manualer