Festo DFPD-10 Manual
Læs nedenfor 📖 manual på dansk for Festo DFPD-10 (5 sider) i kategorien Måling. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/5
DFPD-...
Semi-rotary drive
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instruction
8202412
2023-11f
[8202414]
8202412
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
1 About this document
1.1 Purpose of the document
This document describes the use of the above-mentioned product. It contains
additional information for the use of the product in safety-related systems (safety
manual in accordance with IEC61508).
1.2 Applicable documents
All available documents for the product
èwww.festo.com/sp.
1.3 Target group
This document is targeted towards individuals who mount and operate the
product. It is additionally targeted towards individuals who are entrusted with
the planning and application of the product in a safety-oriented system.
1.4 Product version
This document refers to the standard version of the quarter turn actuator DFPD of
the following product versions.
–DFPD-10…-2300: product labelling without revision number
–DFPD-10…-300: product labelling with revision number [Rev.01]
This document does not apply to the variants DFPD-…-T4 and DFPD-…-T6 with
extended temperature range.
1.5 Specified standards
Version
IEC 61508-1:2010 IEC 61508-7:2010
IEC 61508-2:2010 IEC 61511:2016
IEC 61508-4:2010
Tab. 1: Specified standards
2 Safety
2.1 General safety instructions
–Only use the product in its original condition without unauthorised modifica-
tions.
–Only use the product if it is in perfect technical condition.
–Observe the identifications on the product.
–Before working on the product, switch off the compressed air supply and lock it
to prevent it from being switched on again.
–Take into account the ambient conditions at the location of use. Corrosive
environments reduce the service life of the product.
–Protect the product from fluctuations in pressure: use a pressure control valve.
Return to Festo
Hazardous substances can endanger the health and safety of persons and cause
damage to the environment. To prevent hazards, the product should only be
returned if explicitly requested by Festo.
–Consult your regional Festo contact.
–Complete the declaration of contamination and attach it to the outside of the
packaging.
–Comply with all legal requirements for the handling of hazardous substances
and the transport of dangerous goods.
2.2 Intended use
The quarter-turn actuator operates process valves in fluid systems, (e.g. ball
valves or butterfly valves).
NOTICE
The operating torque of the actuator must not be greater than the maximum
permissible torque specified in ISO5211 in relation to the size of the mounting
flange and coupling.
NOTICE
Depending on the design, part-turn actuators that are moved to a defined
switching position by spring force in a de-energised state lose at least 30% of
their calculated torque as a result of the relaxation of the spring assemblies and
friction.
• Take an appropriate safety factor into account in the application.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have knowledge
and experience in process automation.
3 Additional information
–Contact the regional Festo contact if you have technical problems
èwww.festo.com.
–Accessories and spare parts èwww.festo.com/catalogue.
4 Information on functional safety
4.1 Achievable safety classification
The product is suitable for use as an element in a safety-related system in accord-
ance with IEC61511.
–In Low Demand Mode up to SIL2
–In High Demand Mode up to SIL1
Taking into account the required minimum hardware fault tolerance (HFT=1), the
product can also be used up to SIL3 in a redundant configuration of the entire
system.
NOTICE
The suitability for certain applications can only be determined in connection with
the assessment of further components of the subsystem. These must achieve the
same safety level.
4.2 Safety function
Double-acting semi-rotary drives DFPD-...-RD/-LD
The safety function is to switch the actuator to the defined safety switching
position. This switching movement is achieved by pressurising the corresponding
pressure chamber with compressed air. The value of the torque generated
depends on the pressure difference between the two pressure chambers sepa-
rated by the piston.
Single-acting semi-rotary drives DFPD-...-RS/-LS
The safety function is to switch the actuator to the defined safety switching
position when the compressed air is switched off and the spring chamber is
exhausted. This switching movement is achieved through the spring force of the
spring assembly.
4.3 Operating conditions
–General information on safe operation
è2Safety.
–Periodic tests (function test) è11Maintenance, è11.1 General.
–Ambient conditions and other technical specifications è15Technical data.
4.4 Limitations of use
If used in a safety-related system, the service life is limited to 8years subject to
compliance with the operating conditions.
–Recommended interval for a complete function test: 1year
–Maximum permissible interval for a complete function test: 3years
When a function test is negative, maintenance work must be carried out immedi-
ately.
Produkt Specifikationer
Mærke: | Festo |
Kategori: | Måling |
Model: | DFPD-10 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Festo DFPD-10 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Måling Festo Manualer
17 November 2024
17 November 2024
Måling Manualer
- Måling Bosch
- Måling SilverCrest
- Måling Hager
- Måling DeWalt
- Måling Extech
- Måling Silverline
- Måling IFM
- Måling Pioneer
- Måling Finder
- Måling Mitsubishi
- Måling Braun
- Måling Metrix
- Måling TFA
- Måling Garmin
- Måling Pyle
- Måling Güde
- Måling ABB
- Måling Hama
- Måling BENNING
- Måling Smartwares
- Måling Laserliner
- Måling Black And Decker
- Måling Trotec
- Måling Hilti
- Måling Soehnle
- Måling König
- Måling Powerfix
- Måling Flexa
- Måling Danfoss
- Måling Bresser
- Måling Alecto
- Måling Contec
- Måling VDO
- Måling Westfalia
- Måling Basetech
- Måling Voltcraft
- Måling Testboy
- Måling Velleman
- Måling FLIR
- Måling Perel
- Måling Vemer
- Måling ORNO
- Måling Amprobe
- Måling Fluke
- Måling Stabila
- Måling Ridgid
- Måling Sun Joe
- Måling ADE
- Måling Projecta
- Måling Hazet
- Måling Park Tool
- Måling Pantone
- Måling Testo
- Måling GW Instek
- Måling Brandson
- Måling Etymotic
- Måling Cablexpert
- Måling Kopp
- Måling Eltako
- Måling Eastron
- Måling Vimar
- Måling Klein Tools
- Måling PeakTech
- Måling Uni-T
- Måling Kübler
- Måling Kern
- Måling Chauvin Arnoux
- Måling Megger
- Måling Peak
- Måling TDE Instruments
- Måling ClimeMET
- Måling Adwa
- Måling Gossen Metrawatt
- Måling Siglent
- Måling Hikmicro
- Måling Pico
- Måling Sonel
- Måling Murideo
- Måling Workzone
- Måling Sauter
- Måling Sikkens
- Måling X4-LIFE
- Måling Tru Components
- Måling Berger & Schröter
- Måling Histor
- Måling PCE Instruments
- Måling MSW
- Måling Crelando
- Måling CSL
- Måling Stamos
- Måling Stelzner
- Måling Dranetz
- Måling Clare
Nyeste Måling Manualer
15 November 2024
15 November 2024
15 November 2024
15 November 2024
15 November 2024
12 November 2024
12 November 2024
11 November 2024
5 November 2024
5 November 2024