Jabsco 3270-200 Manual

Jabsco Pomp 3270-200

Læs nedenfor 📖 manual på dansk for Jabsco 3270-200 (2 sider) i kategorien Pomp. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Model 3270-0001
Model 3270-0001
SELF-PRIMING PUMP
FEATURES
Body: Bronze
Impeller: Jabsco Neoprene Compound
Ports: Lip Type
Ports: ¾" NPT
Weight: 4 lb (1.8 kg) Approx.
APPLICATION
Marine Engine Cooling
Perkins Model 4-107 and 4-108
INSTALLATION INSTRUCTIONS
NOTICE: If installing this pump on a Perkins 4-107 or
4-108 engine, it is essential that the pump shaft is
properly aligned with the driving-shaft on the engine. If
the pump adaptor plate (Perkins Part No. 33154119) that
the pump mounts to has been loosened, it must be
realigned using a special Perkins alignment tool when it
is resecured to the engine. Contact your Perkins
Service Dealer to arrange the adaptor plate realignment.
Failure to have the adaptor plate properly aligned prior
to installing the pump can cause severe damage to the
pump and/or the engine.
Before installing the pump, note the position of the tang
on the engine's pump-driving shaft relative to the pump
mounting studs (holes). Then use a screwdriver or thin
bar inserted between the drive tabs on the pump shaft to
rotate the shaft so it will align with and engage the tang
on the engine's pump-drive.
Install a new gasket between the engine and pump
mounting flange. Then, ensuring the engine's drive tang
and the pump's drive tabs are properly engaged,
position the pump against the engine. Make certain the
pump alignment collar is properly seated in the
registration hole on the engine so the pump mounting
flange fits flush against the engine. Secure the pump
with four nuts or machine screws and lock washers.
OPERATING INSTRUCTIONS
The pump with self-prime with a lift of about three feet
at low or high speeds. Before starting engine ensure
the inlet plumbing, including the inlet through-hull and
scoop is free of blockages or debris. The inlet seacock
and any valves in the inlet plumbing must be fully open.
The water being pumped serves as a lubricant for the
flexible impeller and keeps the impeller and pump cool.
Therefore, do not run the pump dry for more than 30
seconds or the impeller and pump will likely be
damaged.
To winterize the pump, drain the liquid from the impeller
cavity by loosening the end cover screws. Lightly tap
the end cover, if necessary, to break it loose from the
body.
DIMENSIONAL DRAWING


Produkt Specifikationer

Mærke: Jabsco
Kategori: Pomp
Model: 3270-200

Har du brug for hjælp?

Hvis du har brug for hjælp til Jabsco 3270-200 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pomp Jabsco Manualer

Pomp Manualer

Nyeste Pomp Manualer

AstralPool

AstralPool Eco Range Manual

15 December 2024
Gardenline

Gardenline GLRP 300 Manual

15 December 2024
Ozito

Ozito PTP-012A Manual

15 Oktober 2024
MSW

MSW -MN34 Manual

15 Oktober 2024
MSW

MSW -MN34M Manual

15 Oktober 2024
MSW

MSW -AOP40S Manual

15 Oktober 2024
Nefit

Nefit VentiLine Manual

12 Oktober 2024