Kyoritsu KEW Snap 2031 Manual

Kyoritsu Multimeter KEW Snap 2031

Læs nedenfor 📖 manual på dansk for Kyoritsu KEW Snap 2031 (2 sider) i kategorien Multimeter. Denne guide var nyttig for 27 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
INSTRUCTIONMANUAL
DIGITALACCLAMPMETER
KEW SNAP 2031
Jaw Trigger Range Switch
Data Hold Button
Transformer Jaws Display
Barrier
Barrier
Itisapartprovidingprotectionagainstelectricalshockand
ensuringtheminimumrequiredairandcreepagedistances.
KEW SNAP
1.SAFETY WARNINGS
This instrument has been designed and tested according to IEC
Publication 61010-1, Safety Requirements for Electronic Measuring
Apparatus. This instruction manual contains warnings and safety rules
which must be observed by the user to ensure safe operation of the
instrument and retainitin safe condition. Therefore, read through these
operatinginstructionsbeforeusingtheinstrument.
   # WARNING
Readthroughandunderstandinstructionscontainedinthismanual
beforestartingusingtheinstrument.
Keepthemanualhandytoquickreferencewhenevernecessary.
Besuretousetheinstrumentinitsintendedapplicationsonlyand
tofollowmeasurementproceduresdescribedinthemanual.
Besuretounderstandandfollowallsafetyinstructionscontained
inthemanual.
Failuretofollowtheaboveinstructionsmaycauseinjury,
instrumentdamageand/ordamagetoequipmentundertest.
Kyoritsuisbynomeansliableforanydamageresultingfromthe
instrumentincontradictiontothiscautionarynote.
Thesymbol
#
indicatedonthe instrumentmeansthattheuser must
refer to related parts in the manual for safe operation of the
instrument. Be sure to carefully read instructionsfollowingeach
#
symbolinthismanual.
#
DANGER
Conditions and actions that are likely to cause
seriousorfatalinjury.
#
WARNING
Conditionsandactionsthatcouldcauseseriousor
fatalinjury.
#
CAUTION
Conditions and actions that could cause minor
injuryorinstrumentdamage.
Followingsymbolsareusedontheinstrumentandintheinstructionmanual.
Attentionshouldbepaidtoeachsymboltoensureyoursafety.
Refertotheinstructionsinthemanual.
Indicatesaninstrumentwithdoubleorreinforcedinsulation.
Indicates that this instrument can clamp on bare conductors when
measuring a voltage corresponding to the applicable Measurement
category,whichismarkednexttothissymbol.
IndicatesAC(AlternatingCurrent).
Earth
ThisinstrumentsatisfiesthemarkingrequirementdefinedintheWEEE
Directive(2002/96/EC). Thissymbol indicates separatecollection for
electricalandelectronicequipment.
 #
DANGER
Never make measurement on a circuit above 300V AC. The
instrument is designed for measurement on a low-voltage circuit
below300VAC.
Donotattempttomakemeasurementinanexplosiveatmosphere
i.e.inthepresenceofflammablegassesorfumes,vaporordust
.
The transformer jaws are made of metal and their tips are not
insulated. Be especially careful about the hazard of possible
shortingwhereequipmentundertesthasexposedconductiveparts.
Neverattempttousetheinstrumentiftheinstrumentoryourhand
iswet.
Do not exceed the maximum allowable input value of any
measurementrange.
Never open the battery compartment cover when making
measurement.
Nevertrytomakemeasurementifanyabnormalconditions,such
asbrokenTransformerjawsorcaseisnoted.
The instrument is to be used only in its intended applications or
conditions.
Otherwise,safetyfunctionsequippedwiththeinstrumentdoesn
twork,
andinstrumentdamageorseriouspersonalinjurymaybecaused.
#
WARNING
Neverattempttomakeanymeasurementiftheinstrumtenthasany
structural abnormality such as cracked case and exposed metal
part.
Do not install substitute parts or make any modification to the
instrument.ReturntheinstrumenttoKyoritsuoryourdistributorfor
serviceandrepairtoensurethatsafetyfeaturesaremaintained.
Always switch off the instrument before opening the battery
compartmentcoverforbatteryreplacement.
#
CAUTION
Makesure that the range switch is set toan appropriate position
beforemakingmeasurement.
Be sure to set the range switch to the OFF position after use.
Whenthe instrument will not be in use for a long period of time,
placeitinstorageafterremovingthebatteries.
Do not expose the instrument to the direct sun, extreme
temperaturesordewfall.
Useadampclothanddetergentforcleaningtheinstrument.Donot
useabrasivesorsolvents.
Measurement Category

To ensure safe operation of measuring instruments, IEC 61010
establishes safety standards for various electrical environments,
categorizedasOtoCATIV,andcalledmeasurementcategories.Higher-
numbered categories correspond to electrical environments with greater
momentary energy, so a measuring instrument designed for CAT III
environments can endure greater momentary energy than one designed
forCATII.

O :Circuits which are not directly connected to the mains power
supply.

CATII :Electrical circuits of equipment connected to an AC electrical
outletbyapowercord.

CATIII :Primaryelectricalcircuitsoftheequipmentconnecteddirectlyto
thedistributionpanel,andfeedersfromthedistributionpanelto
outlets.

CATIV :The circuit from the service drop to the service entrance, and
to the power meter and primary over-current protection device
(distributionpanel).
O: Device which is
not directly
connected to the
mains power supply
2.FEATURES
Pocket-size,miniatureACclampmeter
Teardropshapedjawsforeaseofuseincrowdedcableareasandother
tightplaces
DesignedtointernationalsafetystandardIEC61010-1
CAT
300V
Awiderangeoffrequencyresponsefrom40Hzto1kHz
Dataholdfunctiontoallowforeasyreadingsindimlylightorhard-to-read
locations
Auto-power-offfunctiontoconservebatterypower
3.SPECIFICATIONS
Range
20A
200A
Accuracy
0
19.99
0
199.9
±
2.0%rdg
±
5dgt
50Hz
1kHz
±
2.0%rdg
±
5dgt
50
60Hz
±
3.0%rdg
±
10dgt
40Hz
1kHz
OperatingSystem Dualintegration
Display Fieldeffectliquidcrystaldisplay
MeasuringRanges 20A/200AAC
LowBatteryIndicatio "BATT"symbolappearsonthe
display
OverrangeIndication "1"flashesonthehighestdigit
ResponseTime Approx.1second
AutoPowerOff Theinstrumentautomaticallyshuts
offapprox.10minutesafterbeing
turnedon.
DataHold Forallranges
Locationforuse Indooruse,Altitudeupto2000m
StorageTemperature&Humidity -10
50
,relativehumidityupto
75
withoutcondensation
OperatingTemperature&Humidity 0
40
,relativehumidityupto
90
withoutcondensation
ConductorSize Approx.24mmindiameter
SafetyStandard IEC61010-1CAT
300V
 IEC61010-2-032
EMC EN61326-1
RoHS EN50581
Dimension 147
L
×
59
W
×
26
D
mm
Weight Approx.100g
batteryincluded
PowerSource TwoLR-44
3V
orSR-44batteries
BatteryLife Approx.100hoursincontinuous
use
CurrentConsumption Approx.
mA
Accessories InstructionManual
 TwoLR-44batteries
 CarryingCaseModel9090
4.OPERATlNG INSTRUCTIONS
4−1Battery Check
Settherangeswitchto20Aor200A
Ifthe display is clearwithout showing symbol "BATT",battery voltageis
OK.
If the display remains blank or symbol "BATT" appears, replace the
batteriesin accordancewith thebattery replacement procedures as
outlinedinsection5.
4−2AC Current Measurement
# CAUTION
The maximum size conductor to be tested is approx. 24 mm in
diameter. An accurate measurement cannot be made when the
transformer jaws are not fully closed on a conductor larger than
24mm.
When measuring a large current, the transformer jaws may buzz.
Thisisnotafaultanddoesnotaffecttheaccuracy.
About10minutesaftertheinstrumentisturnedon,theAutoPower
Off function turns the instrument off even during current
measurement.Tocontinue measurement,turn therange switch to
OFF,thento20Aor200Aagain.
# DANGER
Neverusetheinstrumentonacircuitabove300VAC.
The transformer jaws are made of metal and their tips are not
insulated. Be especially careful about the hazard of possible
shortingwhereequipmentundertesthasexposedconductiveparts.
Donotattempttomakemeasurementwiththebatterycompartment
coverremovedfromtheinstrument.
Keep your fingers and hands behind the barrier during
measurement.
Settherangeswitchto20Aor200A.
Pressthejawtriggertoopenthetransformerjawsandclampontoone
conductor only.  Try to place the conductor at the center of the
transformerjaws.
Correct Wrong
4−3Using Data Hold Function
PresstheDataHoldbuttontofreezethereading.Symbol"H"isdisplayed
toindicatetheinstrumentbeingintheDataHoldmode.
Press the button again to cancel the Data Hold mode.  The Data Hold
function is available on both 20A and 200A ranges for measurement in
hard-to-readlocations.
5.BATTERY REPLACEMENT
Whenthedisplayremainsblankorsymbol"BATT"appears,replacethe
batteries.
# DANGER
Neverreplacethebatterieswhilemakingmeasurement.
SettherangeswitchtotheOFFposition.
Press in the hole on the battery compartment cover with the tip of a
pointedobject,thenslideopenthecover.
Replacethebatterieswithnewones,observingcorrectpolarity.
ReplacementbatteriesshouldbetypeLR-44orSR-44.
 *
Theinstrumentdoesnotoperateifthepolarityissetreversely.
Slidethebatterycompartmentcoverinplace.
Kyoritsureservestherightstochangespecificationsordesigns
describedinthismanualwithoutnoticeandwithoutobligations.
4-19
DISTRIBUTOR
92-1354H


Produkt Specifikationer

Mærke: Kyoritsu
Kategori: Multimeter
Model: KEW Snap 2031

Har du brug for hjælp?

Hvis du har brug for hjælp til Kyoritsu KEW Snap 2031 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Kyoritsu Manualer

Multimeter Manualer

Nyeste Multimeter Manualer