Kyoritsu KEW2046R Manual
Kyoritsu
Multimeter
KEW2046R
Læs nedenfor 📖 manual på dansk for Kyoritsu KEW2046R (2 sider) i kategorien Multimeter. Denne guide var nyttig for 15 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
INSTRUCTION MANUAL 1. Features
● Designed to meet international safety standards.
IEC61010-1.IEC61010-031 & IEC61010-2-032
Measurement Category (CAT) IV 600V
Pollution Degree 2
●
Double molded main body provides comfortable
single handed grip
●
Data Hold Function
●
LCD Backlight function to facilitate working at dimly
lit situations.
●
REL function to indicate measurement variation
(Current, voltage, Resistance measurement)
●
MIN/MAX function enables easy reading of min &
max value during measurement.
●
PEAK Hold Function enables Peak value measure-
ment of starting current. (only at ACA Range)
● With Continuity & Diode Check Function
● Capacity measurement of capacitors
●
Temperature measurement, switchable between ℃
and ℉
●
NCV (Non Contact Voltage) Function for wiring check
●
600V input protection
●
Sleep Function to extend battery life
●
With Bar Graph, 6039 count display
2. Safety Warnings
This instrument has been designed,manufactured and
tested according to IEC 61010: Safety requirements
for Electronic Measuring apparatus, and delivered in
the best condition after passed the inspection.
This instruction manual contains warnings and safety
rules which must be observed by the user to ensure
safe operation of the instrument and retain it in safe
condition.
Therefore, read through these operating instructions
before using the instrument.
# WARNING
●
Read through and understand the instructions
co nta ine d in this ma nua l be fo r e usi ng the
instrument.
●
Keep the manual at hand to enable quick reference
whenever necessary.
●
The instrument is to be used only in its intended
applications.
●
Understand and follow all the safety instructions
contained in the manual.
●
It is essential that the above instructions are
adhered to.
Failure to follow the instructions may cause injury,
instrument damage and/or damage to equipment
under test. Kyoritsu is by no means liable for any
damage resulting from the instrument in contradiction
to this cautionary note.
The symbol indicated on the instrument means #
that the user must refer to the related parts in the
manual for safe operation of the instrument. It is
essential to read the instructions wherever the #
symbol appears in the manual.
# DANGER is reserved for conditions and actions
that are likely to cause serious or fatal injury.
# WARNING is reserved for conditions and actions
that can cause serious or fatal injury.
# CAUTION is reserved for conditions and actions
that can cause injury or instrument damage.
●
Marks listed in the table below are used on this
instrument.
#User must refer to the manual.
Instrument with double or reinforced insulation
Indicates that this instrument can clamp on
bare conductors when measuring a voltage
corresponding to the applicable measurement
category, which is marked next to this symbol.
AC
DC
AC & DC
Thi s ins t r um e nt s a t i s f i e s t he m a r k i ng
requirement defined in the WEEE Directive.
This symbol indicates separate collection for
electrical and electronic equipment.
# DANGER
●
Never make measurement on a circuit in which
voltage over AC600V exists.
●
Do not attempt to make measurement in the
presence of flammable gasses. Otherwise, the
use of the instrument may cause sparking, which
can lead to an explosion.
●
Transformer jaw tips are designed not to short the
circuit under test. If equipment under test has
exp o sed co nd ucti ve pa rt s, howe ve r, extra
precaution should be taken to minimize the
possibility of shorting.
●
Never attempt to use the instrument if its surface
or your hand is wet.
●
Do not exceed the maximum allowable input of
any measuring range.
●
N e v e r o p e n t h e B a t t e r y c o v e r d u r i n g a
measurement.
●
The instrument is to be used only in its intended
applications or conditions. Otherwise, safety
functions equipped with the instrument doesn't
work, and instrument damage or serious personal
injury may be caused.
●
Verify proper operation on a known source before
use or taking action as a result indication of the
instrument.
●
Keep your fingers and hands behind the protective
fingerguard during measurement.
# WARNING
●
Never attempt to make measurement if any
abnormal conditions, such as broken case and
exposed metal parts are found on the instrument.
●
Do not rotate the Function Switch while the test
leads are being connected.
●
Do not install substit ute parts or make any
modification to the instrument. For repair or re-
calibration, return the instrument to your local
distributor from where it was purchased.
●
Do not try to replace the batteries if the surface of
the instrument is wet.
●
Disconnect all the cords and cables from the
object under test and power off the instrument
before opening the Battery Cover for Battery
replacement.
●
Stop using the test lead if the outer jacket is
damaged and the inner metal or color jacket is
exposed.
# CAUTION
●
Set the Function Switch to an appropriate position
before starting measurement.
● Firmly insert the test leads.
●
Disconnect the test leads from the instrument for
current measurement.
●
Do not expose the instrument to the direct sun,
high temperature and humidity or dewfall.
●
Altitude 2000m or less. Appropriate operating
temperature is within 0 and 40 .℃ ℃
●
This instrument isn't dust & water proofed. Keep
away from dust and water.
●
Be sure to power off the instrument after use.
When the instrument will not be in use for a long
period, place it in storage after removing the
batteries.
●
Use a cloth dipped in water or neutral detergent
for cleaning the instrument. Do not use abrasives
or solvents.
Measurement Category
To ensure safe operation of measuring instruments,
IEC 61010 establishes safety standards for various
electrical environments, categorized as O to CAT IV,
and called measurement categories. Higher-numbered
categories correspond to electrical environments with
greater momentary energy, so a measuring instrument
designed for CAT III environments can endure greater
momentary energy than one designed for CAT II.
O : Circuits which are not directly connected to
the mains power supply.
CAT II : Electrical circuits of equipment connected
to an AC electrical outlet by a power cord.
CAT III : Primary electrical circuits of the equipment
connected directly to the distribution panel,
and feeders from the distribution panel to
outlets.
CAT IV : The circuit from the service drop to the
service entrance, and to the power meter
and primary over-current protection device
(distribution panel).
DIGITAL CLAMP METER
KEW SNAP SERIES
KEW2046R 600A TRMS Type
KEW2056R 1000A TRMS Type
3. Specification
3-1. Measuring range & accuracy
(accuracy guaranteed at 23℃ ℃±5 , humidit y
45~85%) AC Current 600A, 1000A Function
Function Measuring
Range
Accuracy
KEW2046R KEW2056R
600A
0-600.0A
Peak 1500A
CF=2.5@600A
CF=3.0@500A
±2.0%rdg±5dgt(50/60Hz)
±3.5%rdg±5dgt(40~500Hz)
±5.5%rdg±5dgt(500~1kHz)
* Add 2% at CF>2
1000A
0-1000A
Peak 1500A
CF=2.5@600A
CF=3.0@500A
DC Current 600A, 1000A Function
Function Measuring
Range
Accuracy
KEW2046R KEW2056R
600A 0-600.0A ±1.5%rdg±5dgt ±1.5%rdg±5dgt
1000A 0-1000A
AC Voltage Function
(Auto-ranging, Input impedance: approx. 10M )Ω
Range Measuring
Range
Accuracy
KEW2046R KEW2056R
6/60/600V
0-600.0V ±1.5%rdg±4dgt (50/60Hz)
±3.5%rdg±5dgt (40~400Hz)
DC Voltage Function
(Auto-ranging, Input impedance: approx. 10M )Ω
Range Measuring
Range
Accuracy
KEW2046R KEW2056R
600mV/6/6
0/600V
0-600.0V ±1.0%rdg±3dgt
Resistance (Diode Check/ Continuity/ Capacity)
Range Measuring
Range
Accuracy
KEW2046R KEW2056R
600/6k/60k/
600k/6MΩ
0-6.000M ±1.0%rdg±5dgtΩ
60MΩ
6.00M-60.00MΩ
±5%rdg±8dgt
Cont Buzzer
0-600.0 Buzzer sounds at 100 or lessΩ Ω
Diode Test voltage: 0-2V
Capacity Function
Range Measuring
Range
Accuracy
KEW2046R KEW2056R
40nF
0.01nF
-4000 Fμ
Auto-ranging
the accuracy is not guaranteed
400nF
±2.5%rdg±10dgt4 Fμ
40 Fμ
400 F the accuracy is not guaranteedμ
4000 F the accuracy is not guaranteedμ
Frequency/DUTY Function(Auto-ranging for Frequency)
Range Measuring
Range
Accuracy
KEW2046R KEW2056R
ACA
40Hz-400Hz
±0.5%rdg±5dgt
ACV
1Hz 10kHz〜
0.1-99.9%
(Pulse width/Pulse period)
±2.5%rdg±5dgt
Note: Me as ur a b le i np ut s a re : 40Vr m s@ AC V o r
50Arms@AC600A, 350A@AC1000A Range
Temperature Function
Range Measuring
Range
Accuracy
KEW2046R KEW2056R
℃
-50 ~℃
0℃
±5 ±5dgt℃
0 ~℃
150℃
±3 ±2dgt℃
150 ~℃
700℃
±2%rdg±2dgt
℉
-58
℉
~
32
℉ ℉±9 ±5dgt
32
℉
~
302
℉ ℉±5 ±2dgt
302
℉
~1292
℉±2%rdg±2dgt
Above specified accuracy is applied to Clamp meter
itself. Accuracy of Temperature probe is excluded.
When measuring temperature, include the accuracy of
the temperature probe used.
3-2. General Specification
●
Mode of operation :
△
modeΣ
●
Display : max. 6039 counts
(Frequency: 9999, Capacity &Temperature:4039)
& Bar graph
●
Over-range indication : "OL" displayed when exceeding
the measuring range.
(except for AC/DCV and 1000A Function)
●
Range switching :
Auto-ranging/Voltage, Resistance, Capacity Range
Single range / Continuity, Diode check, DUTY and
Temperature
●
Sample rate : three times per second
●
Functional construction
:
OFF/ ACA/ ACV/ DCA/ DCV/ / / Ω℃ ℉
●
Keys :
SELECT(AC/DC switching &/ / Ω / / ),
PEAK HOLD/ Back Light, REL
△
,Hz/DUTY, MIN/MAX
●
Power source : DC3V/ R03(UM-4) x 2pcs
●
Low battery warning : " " mark is displayed at
2.4V±0.15V or less.
●
Temperature & humidity
: 23 , relative humidity ℃ ℃±5
accuracy guaranteed 85% or less (no condensation)
●
Operating temperature
:
0~40 , relative humidity 85%℃
& humidity range or less (no condensation)
●
Storage temperature : -20~60 , relative humidity ℃
& humidity range
85% or less (no
condensation)
●
Current consumption : approx. 25 mA
●
Sleep Function : Automatically powered off in about
15 min after the last Function switch operation.
Rotate t he Funct i o n Switch from O FF to any
position to exit from the Sleep state.
●
Location for use
Outdoor use, Altitude up to 2000m
●
Applicable Standards
IEC 61010-1, 61010-2-032, 61010-2-033
Measurement CAT IV 600V Pollution degree 2
IEC 61010-031
EMC EN 61326-1:
・ EN 55022
・ EN 61000-4-2 (performance criterion B)
・ EN 61000-4-3 (performance criterion B)
RoHS : EN 50581
●
Overload Protection
Current Range : 720A AC/ 10 sec@KEW2046R
1200A AC/DC/ 10 sec@KEW2056R
Voltage Range : 720V AC/DC/ 10sec
Resistance Range : 600V AC/DC/ 10sec
●
Withstand Voltage
6720V AC ( )TRMS 50/60Hz / 5 sec
(between Jaws and electrical circuit/ between
internal circuit and enclosure)
●
Insulation Resistance
: 10M or more/ 1000V Ω
(between electrical circuit and enclosure)
●
Conductor size
KEW2046R: approx. 33mm
KEW2056R: approx. 40mm
●
Dimension
approx. 254(L)×82(W)×36(D)mm / KEW2056R
approx. 243(L)×77(W)×36(D)mm / KEW2046R
● Weight : approx 300g @ KEW2046R
310g @ KEW2056R
● Accessories
Test Leads M-7066A / 1 set
Battery R03 UM-4 / 2pcs( )
Instruction manual English, Japanese / 1pce
Carrying Case M-9094 / 1pcs
● Optional Accessories
K-type Temperature Probe M-8216
Accuracy ±1.5%rdg±1.5℃
Guaranteed accuracy range:
20 (68℃℉ ℉)~300 (572℃)
● Effective Value (RMS)
Most # alternating currents and voltages are
expressed in effective values, which are also
referred to as RMS (Root-Mean-Square) values.
The effective value is the sq uare root of the
average of square of alternating current or voltage
values. Many clamp meters using a conventional
re ct i f y ing c irc ui t ha v e " RM S" s ca le s f o r AC
measurement. The scales are, however, actually
calibrated in terms of the effective value of a sine
wave though the clamp meter is responding to the
average value. The calibration is done with a
conversion factor of 1.111 for sine wave, which is
found by dividing the effective value by the average
value. These instruments are therefore in error if the
input voltage or current has some other shape than
sine wave.
●
CF (Crest Factor) is found by dividing the peak
value by the effective value.
Examples: Sine wave: CF=1.414
Square wave with a 1: 9 duty ratio: CF=3
3-3. Function Keys
The "●" mark shows available function at each
Range.
HOLD PEAK
SELECT
ZERO Hz/
DUTY
MAX/
MIN
ACA ●●●●●●
ACV ● ● ● ●- -
DCA ● ● ● ●- -
DCV ● ● ●- - -
Ω ● ● ● ●- -
- - - - -●
- - - - -●
● ● ●- - -
TEMP ● ● ● ●- -
4. Preparation for measurement
4-1. Checking Battery Voltage
Set the Function Switch to any position other than
"OFF". When the display is clear without "BATT" mark,
showing battery voltage is enough. When the display is
blank or "BATT" mark is indicated, replace the batteries
according to Section 7, Battery Replacement.
# CAUTION
The Sl ee p fe ature a uto ma tic a lly p owe rs t he
instrument off in about 15 min after the last switch or
key operation. Therefore, the display may be blank
even with the Function Switch set to a position other
than "OFF". To operate the instrument in this case,
turn the switch back to the "OFF" position, then to
any other position. Replace the batteries if nothing
was displayed after above operations.
4-2. Checking Switch Setting & Operation
Confirm the Function Switch is set to the correct
pos it io n,the i ns trume nt i s s e t t o t he corre c t
measurement mode,and the Data hold function is
disabled. Otherwise,desired measurement cannot be
made.
Barrier
Protective fingerguard (Barrier):
It is a part providing protection against electrical
shock and ensuring the minimum required air and
creepage distances.
Cap:
Uncapped condition for CAT II environment
Capped condition for CAT III/ IV environments
The Cap shuld be firmly attached to the probes.
Cap Protective fingerguard
Produkt Specifikationer
Mærke: | Kyoritsu |
Kategori: | Multimeter |
Model: | KEW2046R |
Har du brug for hjælp?
Hvis du har brug for hjælp til Kyoritsu KEW2046R stil et spørgsmål nedenfor, og andre brugere vil svare dig
Multimeter Kyoritsu Manualer
20 September 2024
29 August 2024
29 August 2024
29 August 2024
29 August 2024
29 August 2024
28 August 2024
28 August 2024
28 August 2024
5 August 2024
Multimeter Manualer
- Multimeter Bosch
- Multimeter Hager
- Multimeter Owon
- Multimeter Extech
- Multimeter Silverline
- Multimeter Emos
- Multimeter Metrix
- Multimeter TFA
- Multimeter Pyle
- Multimeter Biltema
- Multimeter Abus
- Multimeter Keithley
- Multimeter Hama
- Multimeter Milwaukee
- Multimeter BENNING
- Multimeter Clas Ohlson
- Multimeter Metrel
- Multimeter Laserliner
- Multimeter Parkside
- Multimeter FERM
- Multimeter Stanley
- Multimeter Elro
- Multimeter REV
- Multimeter Elworks
- Multimeter Powerfix
- Multimeter Digitus
- Multimeter Alecto
- Multimeter Schneider
- Multimeter Basetech
- Multimeter Voltcraft
- Multimeter Testboy
- Multimeter Greenlee
- Multimeter Velleman
- Multimeter Somogyi
- Multimeter FLIR
- Multimeter Perel
- Multimeter JUNG
- Multimeter APPA
- Multimeter Amprobe
- Multimeter Fluke
- Multimeter Monacor
- Multimeter Brennenstuhl
- Multimeter Projecta
- Multimeter Maxwell
- Multimeter Testo
- Multimeter GW Instek
- Multimeter Brandson
- Multimeter Ideal
- Multimeter Multimetrix
- Multimeter Mastech
- Multimeter Högert
- Multimeter Brüder Mannesmann
- Multimeter Vimar
- Multimeter Klein Tools
- Multimeter PeakTech
- Multimeter Rigol
- Multimeter Uni-T
- Multimeter Joy-It
- Multimeter Wiha
- Multimeter HT Instruments
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Qian
- Multimeter Aim TTi
- Multimeter Steren
- Multimeter Gossen Metrawatt
- Multimeter Yato
- Multimeter Beha-Amprobe
- Multimeter Bearware
- Multimeter Sonel
- Multimeter Profile
- Multimeter Aldi
- Multimeter Amiko
- Multimeter Workzone
- Multimeter Tacklife
- Multimeter Etekcity
- Multimeter Digi-tool
- Multimeter Skandia
- Multimeter Elma
- Multimeter Hubinont
- Multimeter Kewtech
- Multimeter Strex
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter Caltek
- Multimeter Noyafa
Nyeste Multimeter Manualer
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024
16 Oktober 2024
9 Oktober 2024
6 Oktober 2024
5 Oktober 2024
4 Oktober 2024
1 Oktober 2024