Panamax MIP-20LT Manual


Læs nedenfor 📖 manual på dansk for Panamax MIP-20LT (1 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 2 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
MAX
®
ImagePRO
-20LT
UNSAFE POWER
LINE FAULT
GROUND OK
POWER / FILTRATION OK
TELEPHONE
EQUIP OUT
TELEPHONE
LINE IN
10/100/1000
BASE-T (Cat 5e)
EQUIP OUT
10/100/1000
BASE-T (Cat 5e)
LINE IN
PHONE DSL
LINE
PHONE DSL
LINE
Properly Connecting
Your Surge Protector
To completely protect your equipment
from power surges, every wire leading
into or out of the equipment you want
to protect must be connected to the
appropriate Panamax surge protector.
Damaging lightning and power surges
can get into your system through any
AC power or signal line (phone lines,
grounding wires, LAN cables, modem
cables, etc.) connected to your electri-
cal equipment.
Installation Procedures
1. Turn OFF the power to all equipment that will
be plugged into the unit.
2. Plug the protector into a properly grounded
AC outlet.
3. Once proper AC wiring and grounding has
been established via a green “GROUND OK”
light, plug the equipment to be protected into
the AC outlets on the unit.
4. Note the position of the IN and OUT jack on
the MIP-20LT unit. The IN jacks are for the line
connections that come from the wall or floor
jack. The OUT jacks are the line connections to
your connected equipment.
5. Plug the incoming LAN and/or telephone line
into the appropriate IN jack. The line should now
be connected between the wall and the unit.
6. Plug the LAN and/or phone cord into the
appropriate OUT jack. Plug the other end into
the equipment to be protected.
7. One at a time, turn each piece of connected
equipment ON and check for power and correct
operation.
AC SURGE PROTECTION
Line Voltage……………...............120VAC, 50/60Hz
Maximum Current Rating……….......................20A
EMI/RFI Noise Filtration…. 65 dB (100KHz - 1 MHz)
Thermal Fusing…………….......................…….Yes
AVM (Automatic Voltage Monitoring) Circuitry... Yes
Overvoltage Shutoff…………........…..... 138V ± 8V
Undervoltage Shutoff…….......…............. 86V ± 6V
1-800-472-5555 • www.panamax.com
INS00869-B
10/100/1000BASE-T LAN PROTECTION
Pins Protected………........…...........RJ-45, pins 1-8
Protection Modes…….............…..All pins to ground
Clamping Level……….....................……...........62V
TELEPHONE PROTECTION
Pins Protected………..........…......…RJ-11, pins 4,5
Protection Modes…………..Metallic & Longitudinal
Clamping Level………...........…..…………….260V
Capacitance……………………..…...30pf (approx.)
Protect or Disconnect™ Circuitry…..................Yes
Single Pulse Energy Dissipation……..1650 Joules
Peak Impulse Current………………52,000 Amps
UL 1449 3rd EditionProtection Rating..…… 400V
Protection Modes…………..…...... L-N, L-G, N-G
Initial Clamping Level…………………. 200 Volts
Surge Response Time…………....<1 nanosecond
© Panamax LLC, 1690 Corporate Circle, Petaluma, CA 94954
Specifications due to change without notice due to product upgrades and improvements.
CAUTION: Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and electrical service panel.
INSTRUCTIONS - MIP-20LT
POWER/FILTRATION OK
Indicator light
GROUND OK Indicator light
LINE FAULT Indicator light
UNSAFE POWER Indicator light
Important Safety Points
Panamax surge protectors and the connected
equipment must be indoors in a dry location and in
the same building. Although your Panamax
protector is very durable, the internal components
are not isolated from the environment. Do not
install any Panamax product near heat emitting
appliances such as a radiator or heat register.
Do not install this product where excessive moisture
is present.
It is not uncommon for a building to be improperly
grounded. In order to protect your equipment,
Panamax products must be plugged into a properly
grounded 3-wire outlet. Additionally, building
wiring and grounding must conform to applicable
NEC (USA) or CEC (Canada) codes for the Panamax
warranty to be valid.
Do not use 2-blade ground adapters with this
product. Avoid using extension cords. If used,
the extension cord must be UL or CSA Listed,
minimum 12 AWG, 3-wire grounded, and rated
for 20 Amps.
If your surge protector indicates a Line Fault, do not
use the product. Call your electrician to correct the
building’s wiring.
Power Filtration and Surge
Protection for Digital Office-
Equipment
Filtration Circuitry– This technology provides
enhanced Neutral-to-Ground Noise Filtration
for your digital office equipment. EMI/RFI
noise can contaminate the equipment safety
ground,which in turn will contaminate the
connected digital equipment, and prevent it
from operating at peak performance levels.
GFCI Compatibility
This circuit features an improved 2-stage
common-mode architecture that provides
compatibility for GFCIs per NEC article 250.6.
Noise Filtration -
Circuitry prevents EMI/RFI noise from
contaminating the connected digital equip-
ment through the ground wiring.
Automatic Voltage Monitoring (AVM)
This power monitoring system acts as a gate
to prevent unsafe voltages from damaging
sensitive electronic equipment. It automati-
cally detects a prolonged over-voltage or
under-voltage and disconnects the power to
the connected equipment, then reconnects it
when the power returns to a safe level.
It even protects the MIP-20LT unit.
Wiring Fault Safety Shutoff
This technology will detect a miswired wall
receptacle or an open-ground by monitoring
the voltage between neutral and ground. If
an unsafe condition exists, the MIP-20LT
will disconnect the power from the connect-
ed equipment.
SignalPerfect™ Telephone Line Protection
RJ-11 phone jacks are available to protect
a single-line telephone modem (pins 4,5
protected) with fuseless Auto-Resetting
technology and optimized circuitry to
ensure a clean, clear signal.
Ethernet LAN Protection
RJ-45 jacks are available to protect one
Ethernet 10/100/1000BASE-T network
connection (all pins protected).
LAN Protection In/Out
RJ-45 bi-directional
connectors
Telephone Protection In/Out
RJ-11 In/Out connectors
Separate protection circuits for
10/100/1000BASE-T Ethernet and Telephone
Three-stage, GFCI-Compatible filter circuit
provides high levels of Normal and
Common mode EMI/RFI noise filtration
Two Always-ON
AC outlets
20 Amp
Two rubber strips running the length on bottom
provide a non-slip grip and prevent marring surface.
Eight foot
power cord
POWER ON/PROTEDTION OK-
(green) normally ON - Indicates that
the surge protector is functioning
properly, poweris on, and it is
protecting all connected equipment.
UNSAFE POWER
(red) normally OFF – When lit,
indicates that incoming voltages
are unsafe and the surge protector
has disconnected the power to
protect your equipment.
DSL & Tel Lines Out
DSL Splitter
Tel Line In
LINE FAULT
(red) normally OFF - When lit,
indicates that the wall outlet
is improperly wired.
GROUND OK
(green) normally ON -
Indicates that the wall outlet is
properly grounded.
Diagnostic lights


Produkt Specifikationer

Mærke: Panamax
Kategori: Ikke kategoriseret
Model: MIP-20LT

Har du brug for hjælp?

Hvis du har brug for hjælp til Panamax MIP-20LT stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Panamax Manualer

Panamax

Panamax MIP-20LT Manual

11 December 2024
Panamax

Panamax MD2-AV Manual

10 December 2024
Panamax

Panamax MD2-TL Manual

10 December 2024
Panamax

Panamax MOD-DT4 Manual

10 December 2024
Panamax

Panamax MOD-AT8110 Manual

10 December 2024
Panamax

Panamax MOD-AT4 Manual

10 December 2024
Panamax

Panamax M4LT-EX Manual

10 December 2024
Panamax

Panamax SEP-200 Manual

4 September 2024
Panamax

Panamax MR5100 Manual

29 August 2024
Panamax

Panamax SM3-PRO Manual

29 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Asus

Asus PE2000S Manual

18 December 2024
Acer

Acer AGR200 Manual

18 December 2024
Acer

Acer Nitro NGR200 Manual

18 December 2024
HK Audio

HK Audio Cosmo Manual

18 December 2024
DCS

DCS BC1-25AC Manual

18 December 2024
Fellow

Fellow Clara Manual

18 December 2024
Chauvet

Chauvet WELL Fit X X6 Manual

18 December 2024
KDK

KDK TG3AD1 Manual

18 December 2024