LAN SURGE PROTECTION 1 PAIR OF RJ-45 IN/OUT CONNECTORS
The protection circuit will only function if connected properly.
(IN from wall outlet and OUT to equipment)
COAXIAL SURGE PROTECTION
1 PAIR UNIVERSAL IN/OUT CONNECTORS
RACK MOUNTABLE.
RACK EARS NOT INCLUDED, SOLD SEPARATELY
287/(7287/(7287/(7287/(7287/(7287/(7287/(7
&$796$7
/$1
81,9(56$/
&2$;
3527(&7,21
0$,132:(5
9$&$
 $03&,5&8,7
%5($.(5

6:,7&+('
287/(76

,1287
,1
287
.3
32:(521
Specifications subject to change due to product upgrades and improvements.
*Go to www.panamax.com for detailed noise filtering information.
Español - Para la versión en español de este documento, vaya a www.panamax.com/products
Français - Pour la version espagnole de ce document, allez à www.panamax.com/products
DIN-00011 - REV. B
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article provides
specific guidelines for proper grounding.It specifies that the cable ground shall be connected
to the grounding system of the building and as close to the point of entry as practical.
Front Panel Features
Back Panel Features
MR4000 Features and Specifications
3DQDPD[//&&RUSRUDWH&LUFOH3HWDOXPD&$ZZZSDQDPD[FRP
3DQDPD[//&3DQDPD[/RJRLVD86UHJLVWHUHGWUDGHPDUNRI3DQDPD[
Model MR4000 Reference Guide
AC PROTECTION
Protect or Disconnect Circuitry______________________________________Yes
Patented Power Management Circuit__________________________________Yes
Overvoltage Shutoff__________________________________________140V ±4
Undervoltage Shutoff_________________________________________95V ±3V
Thermal Fusing_________________________________________________Yes
Line Voltage_________________________________________120VAC, 50/60HZ
Initial Clamping Level_______________________________200V Peak, 141VRMS
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)__________________400V
Protection Modes________________________________________ L-N, L-G, N-G
Maximum Current Rating____________________________________15A (1800W)
EMI/RFI Noise Filtration________________________Panamax Level 2 Noise Filtration*
Response Time________________________________________________< 1ns
Single Pulse Energy Dissipation________________________________1350 Joules
Peak Impulse Current_________________________________________52,000 A
LAN PROTECTION
Clamping Level__________________________________________________50V
Compatibility_______________________________________________10/100bT
Wires Protected_______________________________________________8-Wires
Connectors__________________________________________________RJ-45
UNIVERSAL COAX PROTECTION
HD 1080 i/p Ready_______________________________________________Yes
Bidirectional_____________________________________________Yes
Shielded_________________________________________________Yes
Clamping Level_________________________________________________75V
Frequency Range________________________________________OMHz - 2.2 GHz
Insertion Loss______________________________________________<0.5 dB
Connections_____________________________________Female “F”, Gold Plated
15A RESETTABLE CIRCUIT BREAKER
POWER ON / OFF
FOR ALL OUTLETS
8 ft. POWER CORD with
Right Angle
45° Low Profile Plug
ALL AC OUTLETS (FRONT AND BACK) INCLUDE SURGE PROTECTION AND POWER FILTRATION
ON / OFF CONTROL FOR HORIZONTAL BLUE LIGHTS
(Blue lights can be illuminated when power is off)
SAFE POWER AND
FILTRATION INDICATOR
UNSAFE VOLTAGE INDICATOR normally OFF; when lit, indicates that incoming voltage is unsfe
and the surge protector has disconnected the power to protect your equipment.
LINE FAULT INDICATOR Normally not lit.
However, if it is LIT call a licensed electrician for proper and safe wiring for your wall outlet.
FRONT PANEL
CONVENIENCE OUTLET
Key Features
Exclusive Automatic Voltage Monitoring (AVM)
Panamax’s patent pending power monitoring
circuitry constantly monitors the AC line voltage
for unsafe voltage conditions such as momentary
spikes, prolonged over-voltages and undervoltag-
es (brownouts). These unsafe conditions pose a
very dangerous threat to all electronic equipment
within the home. If the MR4000 senses an unsafe
power condition, it will automatically disconnect
power from your equipment from the to protect
equipment from damage. The front panel indica-
tor will also alert users to the power condition.
Once the voltage returns to a safe level, the
MR4000 will automatically reconnect the power
to the outlets.
Protect or Disconnect™ Technologies
In the event of a catastrophic surge such as light-
ning, it completely disconnects AC power to con-
nected equipment.
Front Panel Outlet
MR4000 features a protected and noise filtered
convenience outlet located on the front panel.
Perfect for temporary gaming systems, por-
table electronics (such as music players or smart
phones), or other personal electronics.
Front Panel Lights
Blue decorative lights add an attractive look at feel
to your equipment rack or TV cabinet.
Antenna, Cable, Sat and LAN Signal protection
Coaxial protection circuits prevent damaging
surges from entering through signal paths and
have the smallest signal loss on the market - less
than 0.5 db of attenuation from 0Hz to 2.2GHz.
Our coaxial protection has been specifically
designed to virtually eliminate signal loss. The
clamping level of 75V will meet and exceed the
demands of both cable and satellite voltages
while minimizing exposure to damaging spikes
and surges. LAN protection allows for 10/100
base-T Ethernet equipment to integrate into an
audio/video system without the risk of upstream
surge damage from a gateway, switch, router or
other network device.
Eight Protected and Filtered Power Outlets (see
specifications)
Eight Foot Power Cable with Low Profile Plug
This 45° angle low profile plug allows your
equipment to be as close as it can get to the wall
outlet while not blocking an adjacent outlets.
The 8’ power cord means your installation loca-
tion isn’t restricted by wall outlet location. Don’t
let your electronics control your lifestyle.
TO GET STARTED
1. Turn OFF the power to all equipment that will be plugged into the MR4000.
2. Plug the MR4000 into the wall outlet then turn it ON.
3. Verify that the LINE FAULT INDICATOR LED is NOT lit, indicating that the wall outlet is properly wired and
grounded. (If it is LIT call a licensed electrician to inspect and implement proper and safe wiring).
4. Plug the equipment to be proteced into the MR4000 AC outlets and leave everything off until after the
TELEPHONE and COAX Lines are connected and then proceed to turn on your connected equipment.
IMPORTANT SAFETY POINTS
Panamax surge protectors and the connected equipment must be indoors, in a dry location and in the same
building. Although your Panamax protector is very durable, its internal components are not isolated from the
environment. Do not install any Panamax product near heat emitting appliances such as a radiator or heat register.
Do not install this product where excessive moisture is present; for example near a bath tub, sink, pool basement
floor, fish tank, etc. It is not uncommon for a building to be improperly grounded. In order to protect your equipment,
Panamax products must be plugged into a properly wired and grounded 3-wire outlet. Additionally, building wiring
and grounding must conform to applicable NEC (USA) or CEC (Canada) codes for the Panamax protection policy to
be valid. Do not use 2-blade adapters or any other “power strips” with this product. Use only Panamax extension
cord, or a UL / CSA recognized power cord.


Produkt Specifikationer

Mærke: Panamax
Kategori: Ikke kategoriseret
Model: MR4000

Har du brug for hjælp?

Hvis du har brug for hjælp til Panamax MR4000 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Panamax Manualer

Panamax

Panamax SEP-200 Manual

4 September 2024
Panamax

Panamax MR5100 Manual

29 August 2024
Panamax

Panamax SM3-PRO Manual

29 August 2024
Panamax

Panamax MB850 Manual

29 August 2024
Panamax

Panamax MR4300 Manual

29 August 2024
Panamax

Panamax M4-EX Manual

29 August 2024
Panamax

Panamax M5300-PM Manual

29 August 2024
Panamax

Panamax M4315-PRO Manual

29 August 2024
Panamax

Panamax M5400-PM Manual

29 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer