Prologue K0390 Manual


Læs nedenfor 📖 manual på dansk for Prologue K0390 (4 sider) i kategorien Termometer. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
GREAT BRITAIN: For consumer contact, please visit www.clasohlson.co.uk and click on customer service.
Internet: www.clasohlson.co.uk
17
18
19
20
21
1
2
3
4
5
6 11
12
13
14
15
16
7 10
8 9
201108
Wireless thermometer
Art.no 36-4743 Model 919403 (K0390)
Please read theentire instruction manual before use and save it for future reference.
Wereserve theright for any errors in text or images and for making any necessary technical
changes to this document. Ifyou should have any questions concerning technical problems
please contact our Customer Services.
Product description
Wireless sensor. Cleardisplay showing indoor and outdoor temperature, time and date.
Thesensor can be placed up to 30 m (line-of-sight) away from thereceiver. Supportsup to
three sensors simultaneously.
Buttons and functions
Getting started
1. Remove thebattery cover on theback of thedisplay unit.
2. Insert 2 x AAA/LR03 batteries, observing thecorrect polarity.
3. Refit thebattery cover. Thedisplay now shows thedefault time, calendar and present
indoor temperature and begins searching for anoutdoor temperature signal.
4. Insert 2 x AAA/LR03 batteries into theoutdoor sensor. Theoutdoor temperature and
“CH1” will now appear on thelower half of thedisplay. Thewireless thermometer display
unit is now synchronised with theoutdoor sensor on channel 1 and thetemperature from
that sensor is displayed.
Setting theclock
1. Press and hold [ SET.ALM ] for 2 seconds, and then use or to set theyear. ▲ ▼
2. Press [ SET.ALM ] again, themonth digits start to flash. Use or to set themonths. ▲ ▼
3. Press [ SET.ALM ] again, thedate digits start to flash. Use or to set thedate. ▲ ▼
4. Press [ SET.ALM ] again, “24 Hr” and “12 Hr” start to flash. Use or to set ▲ ▼
thetimeformat.
5. Press [ SET.ALM ] again, “0:00” appears and thehour digits start to flash.
Use or toset thehours. ▲ ▼
6. Press [ SET.ALM ] again, “0:00” appears and theminute digits start to flash.
Use or to set theminutes. ▲ ▼
7. Press [ SET.ALM ] to return to normal mode.
Setting thealarm
1. Press [ SET.ALM ], “AM 7:00 AL” appears on thedisplay.
2. Press and hold [ SET.ALM ] for 2 seconds, then hour digits will start to flash.
Use or to set thehours. ▲ ▼
3. Press [ SET.ALM ] again, theminute digits start to flash. Use or to set theminutes.▲ ▼
4. Press [ SET.ALM ] again, thedigits start to flash and show “05”. Use or to set ▲ ▼
thesnooze duration to from 1 to 20 minutes.
5. Press [ SET.ALM ] to return to normal mode.
Turning thealarm on/off
1. Press [ SET.ALM ] to display thealarm time. Whenthealarm time is displayed,
press once to turn thedaily alarm off.
2. When thealarm function is turned on, the icon is shown on thedisplay.
Snooze
1. When thetime reaches theset alarm time, theclock will beep to wake you.
The icon will flash.
2. To stop thealarm, press .The alarm will stop and the icon stops flashing.
Selecting Celsius or Fahrenheit
1. Press to switch between displaying temperature in degrees Celsius and Fahrenheit.
Reading thehighest and lowest recorded temperature
1. Press [ MAX/MIN ] to view thehighest and lowest indoor and outdoor temperature
respectively.
2. Press and hold [ MAX/MIN ] to clear therecorded value and start recording new data.
Synchronising with multiple outdoor sensors
This unit comes with one sensor. Asecond and athird sensor can be purchased and used
with thethermometer simultaneously.
1. Set thenumber of thechannel on theextra sensor to 2 (under thebattery cover).
2. Press [ CHANNEL ]. “CH2” and “_ _” appear on thelower half of thedisplay./▲
3. Press and hold [ ALM ON/OFF ] for about 2 seconds.
4. Sensor 2 is now synchronised with thethermometer and thetemperature of thesecond
sensor will appear on thedisplay.
5. The same procedure can be repeated for athird sensor.
Care and maintenance
Clean theproduct by wiping it with asoft, dry cloth.
Neveruse solvents or abrasive cleaning agents.
Troubleshooting guide
Problem Solution
Wrongoutdoor temperature
displayed on thereceiver.
Wait 1–2 minutes to make sure that thesensor and
receiver are in sync. Ifnot, resynchronise them.
The temperature on thesensor
seems to be too high.
Make sure that thesensor is not placed in direct sunlight
or next to aheat source.
The receiver cannot receive
signals and display them.
Synchronise theunits again.
The temperature could be under -50 °C.
The sensor’s batteries might need replacing.
Move thereceiver and thesensor closer to each other.
Make sure that thesensor is placed away from
electrical interference.
The functions are abnormal or
certain functions do not work
at all.
The unit needs to be reset. Dothis by removing or
replacing thebatteries in both thereceiver and sensor.
Disposal
Disposal of this product should be in accordance with local regulations.
Ifyou are unsure how to proceed, contact your local authority.
Specifications
Batteries Insert 4 x AAA/LR03 batteries (sold separately)
Size 145 x 72 x 25 mm
Update interval 1 minute
Indoor temperature 0 °C to +50 °C
Outdoor temperature -50 °C to +70 °C
1. Time
2. Date/Month
3. Indoor temperature
4. Outdoor sensor
5. Outdoor temperature
6. [ SET.ALM ] Alarm set
7. Switch between Celsius and Fahrenheit
8. [ MAX/MIN ]
9. [ Reset ]
10. Channel, Alarm on/off
11. [ Snooze ]
12. Sensor
13. Highest/Lowest icons
14. Alarm icon
15. Mounting hole
16. Battery compartment
17. LED
18. [ Reset ]
19. Base
20. Channel 1, 2 or 3
21. Battery compartment


Produkt Specifikationer

Mærke: Prologue
Kategori: Termometer
Model: K0390

Har du brug for hjælp?

Hvis du har brug for hjælp til Prologue K0390 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer Prologue Manualer

Prologue

Prologue K0390 Manual

29 August 2024
Prologue

Prologue 1052 IM Manual

29 August 2024
Prologue

Prologue 36-4744 Manual

28 August 2024

Termometer Manualer

Nyeste Termometer Manualer

TFA

TFA 12.1004 Manual

21 December 2024
Owon

Owon TI219 Manual

21 December 2024
TFA

TFA 30.1000 Manual

17 December 2024
TFA

TFA 14.1503 Manual

17 December 2024
TFA

TFA 15.2010 Manual

17 December 2024
TFA

TFA 30.3053.IT Manual

16 December 2024
Optex

Optex PT-7LD Manual

16 December 2024
Optex

Optex PT-U80 Manual

16 December 2024
Ebro

Ebro TFI 260 Manual

15 December 2024