For your safety
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR
ARC FLASH
Safe electrical installation must be carried out only by
skilled professionals. Skilled professionals must prove
profound knowledge in the following areas:
Connecting to installation networks
Connecting several electrical devices
Laying electric cables
Connecting and establishing KNX networks
Safety standards, local wiring rules and regulations
Failure to follow these instructions will result in
death or serious injury.
RISK OF FATAL INJURY FROM ELECTRIC SHOCK
The output may carry electrical current even when the
load is switched off.
When working on the device: Always disconnect the
device from the supply by means of the fuse in the in-
coming circuit.
Even if the manual switch is in the „OFF“ position, a
KNX telegram can switch the connections to being
live at any time. Before working on the device, always
diconnect the fuse in the incoming circuit from the
supply.
Failure to follow these instructions will result in
death or serious injury.
The device may be damaged!
Always operate the product in compliance with the
specified technical data.
Do not use the current detection function for applica-
tions relevant to safety.
Connect only pure ohmic loads to a channel with di-
rect current (DC).
Only install devices with at least basic insulation next
to the device.
Failure to follow these instruction can result in
equipment damage.
The switch actuator REG-K/4x230/16 with current
detection and manual mode (referred to below as the
actuator) can switch four loads via separate, floating
make contacts.
You can also manually switch the connected loads with
manual switches on the actuator without bus voltage.
The actuator has a bus coupler. It is installed on a
DIN-rail TH 35 according to EN 60715, with the bus
connection made via a bus connecting terminal. It is
supplied with power from the bus voltage. A data rail is
not required.
The actuator also has integrated current detection
which measures the load current of each channel.
ABus connecting terminal, max. 4 core pairs
BCable cover
CProgramming button
DProgramming LED (red LED)
EOperational LED "RUN" (green LED)
FManual switch
GScrew terminals
½CAUTION
Strong magnetic fields can influence the current
measurement. Install devices with a strong
magnetic field (e.g. wound transformers such as
bell transformers) at least 2 cm away from the
actuator.
1Set the actuator onto the DIN rail.
Getting to know the switch actuator
Connections, displays and operating
elements
Mounting the actuator
1234
LL 1 2 LL 3 4
B
C
D
E
F
A
G
2
1
3
2Connect KNX.
¼
WARNING
Risk of fatal injury from electrical current. The
device can be damaged.
Safety clearance must be guaranteed in
accordance with IEC 60664-1. There must be at
least 4 mm between the individual cores of the
230 V supply cable and the KNX line.
3Connect the bus voltage.
4Wait at least 30 seconds.
5Set the relays of the channels to the position
desired simply by switching "On/Off"
or by
changing the manual switch to "OFF".
6Connect the load.
7Connect the mains voltage.
You can now check the function of the connected load
using the manual switch, without having to load the
application from the ETS. (See the "Operating the
actuator" section.)
RISK OF FATAL INJURY FROM ELECTRIC SHOCK
Voltage may be present at the outputs when the mains
voltage is connected to the system.
If subjected to strong vibrations during transportation,
the switch contacts might change to the enabled state.
After connecting the bus voltage, set the relays of the
channels to the position desired simply by switching
„On/Off“ or by changing the manual switch to „OFF“.
Failure to follow these instructions will result in
death or serious injury.
The device may be damaged!
Protect the switch contacts with a series-connected
16 A circuit breaker.
Failure to follow these instruction can result in
equipment damage.
5 mm
1 2
3 4
230 V
4 mm
KNX
KNX
16 A 16 A 16 A
L1 NL3L2
1
4
..........
SpaceLogic KNX
Switch actuator REG-K/4x230/16 with
current detection and manual mode
Operating instructions
Art. no. MTN647595
en
1234
LL 1 2 LL 3 4


Produkt Specifikationer

Mærke: Schneider
Kategori: Ikke kategoriseret
Model: MTN647595

Har du brug for hjælp?

Hvis du har brug for hjælp til Schneider MTN647595 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Schneider Manualer

Schneider

Schneider MTN647595 Manual

20 September 2024
Schneider

Schneider CCT15910 Manual

12 September 2024
Schneider

Schneider VW3A7740 Manual

5 September 2024
Schneider

Schneider VW3A7746 Manual

5 September 2024
Schneider

Schneider VW3A7752 Manual

5 September 2024
Schneider

Schneider VW3A7742 Manual

5 September 2024
Schneider

Schneider VW3A7737 Manual

5 September 2024
Schneider

Schneider VW3A7745 Manual

5 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024