TENT PITCHING INSTRUCTIONS RAVELLO (UK)
Flysheet First Pitching:
Open out flysheet and position in required direction
Peg out the four main corners of the tent using the pegs supplied
Locate inflation points on each beam
Remove the valve cap (figure 1)
Insert the correct pump adaptor, which will lock onto the valve (figure 2 & 3)
There is no need to turn the white valve button as the adaptor will move this to the correct positi on
Inflate all tubes to 7psi. The tubes MUST be guided into an arch as they are inflated.
Final tube pressure MUST NOT exceed 8psi
DO NOT OVER-INFLATE THE BEAMS
Start with the centre tube and guide the beam into an upright position while it is inflating
Inflate the other beams.
A small amount of air may leak from the valve when it is being inflated but this is normal
Remove the pump adaptor as soon as the beam is at the correct psi
Replace the valve cap to create an air tight seal (figure 5 & 6)
Ensure the tent is in a straight line
The groundsheet should be flat and wrinkle free
Peg out the remaining poles and pegging points using pin pegs at the base of poles
Peg out ALL guy lines using pin-pegs ensuring that guy line fabric attachment points are evenly tensioned.
Reposition and adjust tensioning where necessary
Insert the shorter porch pole into front pole sleeve over doorway
Push porch pole into an arch from opposite side and locate pole end onto pin system
CORRECT PUMP SET-UP:
Pump Body > Pressure Valve > Pressure Gauge > Hose
(Ensure the valve/gauge/hose are connected to the inflation port of the pump)
Inner Attachment:
Open out inner tent inside flysheet and position doorways to correspond with the living area
Starting from the rear corners of the tent, attach the elasticated hooks on the groundsheet to corresponding rings on the flysheet
Suspend the inner by attaching toggles of inner tent through rings on inside of flysheet
Do the rear first and work forward
Tension Band System:
Remove Tension Band System from pockets and attach into the corresponding clips at the apex of the pole
Adjust the straps until they are taut
DO NOT OVERTENSION. Excess tension will alter the shape of the tent
TO DEFLATE AIRBEAM/ AIRAWAY/ AIRAWNING:
To deflate the AirBeam (remove the cap (figure 7)) press & turn (figure 8) the button from CLOSED to OPEN
In the unlikely event of a puncture:
Deflate the air beam. Unzip the internal flysheet sleeve which contains the affected beam.
Remove the tube and its protective outer.
The zips for the protective outer are cable tied together to prevent accidental access. Cut the cable tie and open the zip.
DO NOT open these zips when the tube inflated.
Remove the clear rubberised tube from the protective sleeve taking care when removing the valve from the sleeve.
Partially inflate the tube and pass through a bucket or basin of water, looking for air bubbles. This will indicate location of puncture
Use the repair patch provided and cover hole, using instructions on patch. Re-insert tube into protective outer, closing zip from both ends, so that zip pullers are in the flysheet sleeve
(this might be easier with the tube partially inflated)
AIRBEAM INFLATION:
AIRBEAM DEFLATION:
Aufbauanleitung - Ravello (DE)
Mit Außenzeltaufbau zuerst
Außenzelt auslegen und korrekt ausrichten.
Befestigen Sie die 4 Hauptecken des Zelts mit Hilfe der mitgelieferten Heringe
Lokalisieren Inflation Punkte auf jeder Strahl
Entfernen Sie die Ventilkappe
Legen Sie die richtige Pumpenadapter , die auf das Ventil sperren wird
Es besteht keine Notwendigkeit , um die weiße Ventilknopf drehen, da der Adapter wird diese in die richtige Position bewegen
Pumpen Sie alle Schläuche auf 3psi auf. Die Schuche MÜSSEN beim Aufpumpen in einen Bogen geformt werden.
Der Schlauchdruck DARF letztendlich 4psi nicht überschreiten.
TRÄGER NICHT ZU STARK AUFPUMPEN.
Figure 1
Remove
locking cap
Figure 3
Lock locking pump
connector
Figure 4
Inflate with
AirBeam pump
Figure 5
Insert locking
cap
Figure 6
Lock locking cap
Figure 8
Push button to deflate &
twist to open position
Figure 7
Unlock
locking cap
Figure 2
Insert locking pump
connector