The Energy-230 D22 static energy meter is an appliance to read active energy in single-phase
230V systems. It is designed to operate in environments with category of measurement III and
pollution level 2 according to EN 61010-1 standard.
SAFETY WARNINGS
To guarantee correct installation, proceed as follows:
1) The appliance should be installed by a qualified operator
2) The appliance should be installed in a panel in such a way as to guarantee that the terminals are
inaccessible after fitting
3) A protection device against over-currents should be installed in the electrical system, upstream
of the energy meter
4) Connect the instrument as shown in the alongside diagrams
5) Before touching the connector terminals make sure that the wires to be connected or already
connected to the instrument are not live
6) Do not power or connect the instrument if any part of it is damaged
7) The instrument must be installed and activated in compliance with current electric systems
standards.
Code Model Description
VE044400 Energy-230 D22 Single-phase active energy meter
VE055000 Energy-230 D22 PULSE Single-phase active energy meter with pulse output
TECHNICAL SPECIFICATIONS
Power supply: 230 V CA (-15%/+10%), 50/60 Hz
Maximum power consumption: 4VA
Basic current: I = 10Ab
Maximum current: I = 22.5 AMAX
Starting current: 25 mA
Current circuit consumption: < 2.5 VA
Connection type: direct for current conductors
Signaling leds: green = power on
red = flashing at 10Wh
Accuracy: class 2 (EN 62053-21)
Display: LCD, 7 + 5 digit
Partial reading resolution: 0.01kWh (full scale: 999.99 kWh) or
0.1kWh (full scale: 9999.9 kWh)
Total reading resolution: 1 kWh (full scale: 9999999 kWh)
Housing: 2 DIN
Protection degree: IP20/IP51 on the front
Optoinsulated pulse output (only PULSE model) for energy consumption remote-monitoring
(0.1 kWh/pulse)
Pulse specifications: duration = 100 ms ± 15%
voltage = 9 ÷ 24 V CC (± 10%)
switchable output current = 20 mA max
Operating temperature: -10 ÷ +45 °C
Storage temperature: -20 ÷ +60 °C
Relative humidity: 10% ÷ 90% non-condensing
OPERATION
When the energy meter is turned on the main page is displayed,
representing the total energy count on the 7-digit upper block and the
partial energy count on the 5-digit lower block. The resolution of partial
counter is automatically updated as soon as the full scale is reached.
To display the energy reading only, press the “Sel” key: this meter total
cannot be set to zero
To display the energy reading, press the “Sel” key again: this meter partial
is zeroed automatically as soon as the full scale is reached (9999.9 kWh); it
can also be set to zero manually anytime by holding the “Sel” key pressed
for more than 4 seconds
Pressing again the key “Sel” you move to the display of the instantaneous
power. The resolution is fixed at 0.01 kW.
For values higher than 6kW is showed.“---”
To return to the main page reading both meters (total and partial), press the
“Sel” key again
BACKLIGHTING
Backlighting is enabled by default: it is switched on each time a key is
pressed and stays on for 30 seconds after the last key was pressed. In
order to enable/disable backlight while on the page, hold “Sel” key main
pressed for at least 4 seconds: ON/OFF backlight status will be displayed
for a couple of seconds, after which the main page will return.
PHASE ERROR
When the energy meter is turned on, a connection check-up is
automatically carried out to detect any connection errors: in case of
improper connection the red led remains lit and the meter is locked. The
message phase error” is displayed.
Warning: to restore correct meter operation after an error reading has been displayed,
switch the meter off, invert connections of voltage or current and turn on again.
User Manual
SINGLE-PHASE ACTIVE ENERGY METER
Read all the instructions carefully
REFERENCE STANDARS
Conformity to European Community directives:
2006/95/EC (Low Voltage Electrical Equipment)
2004/108/EC (E.M.C.)
is declared according to the following standards:
EN 61010-1, EN 61000-6-2 EN 61000-6-3and
EN 62053-21 EN 62052-11and
DIMENSIONS
CONNECTION DIAGRAM
DESCRIPTION
Mod. Energy-230 D22
Energy-230 D22 PULSE
Terminal block for direct
connection of metering wires
Total energy
Partial energy
Terminal block for pulse output
(only PULSE model)
Energy-230 D22 PULSE
ON
Sel
10Wh/imp
10(22.5)A cl.2
230V~ 50/60Hz
Green led:
lit = power on
Red led:
1 flash = 10Wh
Page / backlight
selection key
Main page
Total reading
Partial reading
Instantaneous power
Backlight status


Produkt Specifikationer

Mærke: Vemer
Kategori: Måling
Model: Energy-230 D22

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer Energy-230 D22 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Vemer Manualer

Måling Manualer

Nyeste Måling Manualer

Sauter

Sauter FA 20 Manual

21 November 2024
Sauter

Sauter TN EE Manual

21 November 2024
Sauter

Sauter FH 2K Manual

21 November 2024
Sauter

Sauter FA 300 Manual

21 November 2024
Sauter

Sauter FH 50K Manual

21 November 2024
Sauter

Sauter FK 25 Manual

21 November 2024
Sauter

Sauter FH 50 Manual

21 November 2024
Sauter

Sauter FH 5K Manual

21 November 2024
Sauter

Sauter FH 100K Manual

21 November 2024
Sauter

Sauter FH 10 Manual

21 November 2024