Vemer Energy-230 D22 Manual
Læs nedenfor 📖 manual på dansk for Vemer Energy-230 D22 (1 sider) i kategorien Måling. Denne guide var nyttig for 14 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/1
V3IS00412-011-082014
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
The Energy-230 D22 static energy meter is an appliance to read active energy in single-phase
230V systems. It is designed to operate in environments with category of measurement III and
pollution level 2 according to EN 61010-1 standard.
SAFETY WARNINGS
To guarantee correct installation, proceed as follows:
1) The appliance should be installed by a qualified operator
2) The appliance should be installed in a panel in such a way as to guarantee that the terminals are
inaccessible after fitting
3) A protection device against over-currents should be installed in the electrical system, upstream
of the energy meter
4) Connect the instrument as shown in the alongside diagrams
5) Before touching the connector terminals make sure that the wires to be connected or already
connected to the instrument are not live
6) Do not power or connect the instrument if any part of it is damaged
7) The instrument must be installed and activated in compliance with current electric systems
standards.
Code Model Description
VE044400 Energy-230 D22 Single-phase active energy meter
VE055000 Energy-230 D22 PULSE Single-phase active energy meter with pulse output
TECHNICAL SPECIFICATIONS
• Power supply: 230 V CA (-15%/+10%), 50/60 Hz
• Maximum power consumption: 4VA
• Basic current: I = 10Ab
• Maximum current: I = 22.5 AMAX
• Starting current: 25 mA≤
• Current circuit consumption: < 2.5 VA
• Connection type: direct for current conductors
• Signaling leds: green = power on
red = flashing at 10Wh
• Accuracy: class 2 (EN 62053-21)
• Display: LCD, 7 + 5 digit
• Partial reading resolution: 0.01kWh (full scale: 999.99 kWh) or
0.1kWh (full scale: 9999.9 kWh)
• Total reading resolution: 1 kWh (full scale: 9999999 kWh)
• Housing: 2 DIN
• Protection degree: IP20/IP51 on the front
• Optoinsulated pulse output (only PULSE model) for energy consumption remote-monitoring
(0.1 kWh/pulse)
• Pulse specifications: duration = 100 ms ± 15%
voltage = 9 ÷ 24 V CC (± 10%)
switchable output current = 20 mA max
• Operating temperature: -10 ÷ +45 °C
• Storage temperature: -20 ÷ +60 °C
• Relative humidity: 10% ÷ 90% non-condensing
OPERATION
• When the energy meter is turned on the main page is displayed,
representing the total energy count on the 7-digit upper block and the
partial energy count on the 5-digit lower block. The resolution of partial
counter is automatically updated as soon as the full scale is reached.
• To display the energy reading only, press the “Sel” key: this meter total
cannot be set to zero
• To display the energy reading, press the “Sel” key again: this meter partial
is zeroed automatically as soon as the full scale is reached (9999.9 kWh); it
can also be set to zero manually anytime by holding the “Sel” key pressed
for more than 4 seconds
• Pressing again the key “Sel” you move to the display of the instantaneous
power. The resolution is fixed at 0.01 kW.
For values higher than 6kW is showed.“---”
• To return to the main page reading both meters (total and partial), press the
“Sel” key again
BACKLIGHTING
• Backlighting is enabled by default: it is switched on each time a key is
pressed and stays on for 30 seconds after the last key was pressed. In
order to enable/disable backlight while on the page, hold “Sel” key main
pressed for at least 4 seconds: ON/OFF backlight status will be displayed
for a couple of seconds, after which the main page will return.
PHASE ERROR
• When the energy meter is turned on, a connection check-up is
automatically carried out to detect any connection errors: in case of
improper connection the red led remains lit and the meter is locked. The
message “phase error” is displayed.
Warning: to restore correct meter operation after an error reading has been displayed,
switch the meter off, invert connections of voltage or current and turn on again.
User Manual
SINGLE-PHASE ACTIVE ENERGY METER
Read all the instructions carefully
REFERENCE STANDARS
Conformity to European Community directives:
2006/95/EC (Low Voltage Electrical Equipment)
2004/108/EC (E.M.C.)
is declared according to the following standards:
EN 61010-1, EN 61000-6-2 EN 61000-6-3and
EN 62053-21 EN 62052-11and
DIMENSIONS
CONNECTION DIAGRAM
DESCRIPTION
Mod. Energy-230 D22
Energy-230 D22 PULSE
Terminal block for direct
connection of metering wires
Total energy
Partial energy
Terminal block for pulse output
(only PULSE model)
Energy-230 D22 PULSE
ON
Sel
10Wh/imp
10(22.5)A cl.2
230V~ 50/60Hz
Green led:
lit = power on
Red led:
1 flash = 10Wh
Page / backlight
selection key
Main page
Total reading
Partial reading
Instantaneous power
Backlight status
Produkt Specifikationer
Mærke: | Vemer |
Kategori: | Måling |
Model: | Energy-230 D22 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Vemer Energy-230 D22 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Måling Vemer Manualer
27 Maj 2024
28 Februar 2024
17 April 2023
27 Marts 2023
9 Marts 2023
13 Oktober 2022
12 Oktober 2022
Måling Manualer
- Måling Bosch
- Måling SilverCrest
- Måling Hager
- Måling Owon
- Måling DeWalt
- Måling Extech
- Måling Silverline
- Måling IFM
- Måling Pioneer
- Måling Finder
- Måling Mitsubishi
- Måling Braun
- Måling Metrix
- Måling TFA
- Måling Garmin
- Måling Pyle
- Måling Güde
- Måling ABB
- Måling Hama
- Måling BENNING
- Måling Smartwares
- Måling Laserliner
- Måling Black And Decker
- Måling Trotec
- Måling Hilti
- Måling Soehnle
- Måling König
- Måling Powerfix
- Måling Flexa
- Måling Festo
- Måling Danfoss
- Måling Bresser
- Måling Alecto
- Måling Contec
- Måling VDO
- Måling Westfalia
- Måling Basetech
- Måling Voltcraft
- Måling Testboy
- Måling Velleman
- Måling FLIR
- Måling Perel
- Måling ORNO
- Måling Amprobe
- Måling Fluke
- Måling Stabila
- Måling Ridgid
- Måling Sun Joe
- Måling ADE
- Måling Projecta
- Måling Hazet
- Måling Park Tool
- Måling Pantone
- Måling Testo
- Måling GW Instek
- Måling Brandson
- Måling Etymotic
- Måling Cablexpert
- Måling Kopp
- Måling Steinberg
- Måling Eltako
- Måling Eastron
- Måling Vimar
- Måling Klein Tools
- Måling PeakTech
- Måling Uni-T
- Måling Joy-It
- Måling Kübler
- Måling Kern
- Måling Chauvin Arnoux
- Måling Megger
- Måling Peak
- Måling TDE Instruments
- Måling ClimeMET
- Måling Adwa
- Måling Gossen Metrawatt
- Måling Siglent
- Måling Hikmicro
- Måling PCE
- Måling Pico
- Måling Sonel
- Måling Murideo
- Måling Workzone
- Måling Sauter
- Måling Sikkens
- Måling X4-LIFE
- Måling Tru Components
- Måling Ebro
- Måling Berger & Schröter
- Måling Histor
- Måling PCE Instruments
- Måling Sanwa
- Måling MSW
- Måling Camille Bauer
- Måling Crelando
- Måling CSL
- Måling Stamos
- Måling Stelzner
- Måling Dranetz
- Måling Clare
- Måling Brookhuis
- Måling Crowcon
- Måling Intact
- Måling PQ Plus
- Måling DriveTest
- Måling Helvi
Nyeste Måling Manualer
16 December 2024
16 December 2024
15 December 2024
15 December 2024
15 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
13 December 2024