SINGLE-PHASE ACTIVE ENERGY METER
Read all the instructions carefully
V3IS00417-010-082010
Mod. Energy-230 LC
The Energy-230 LC static energy meter is an appliance to read active energy in single-phase
230V systems. It is designed to operate in environments with measurement category III and
pollution level 2 according to EN 61010-1 standard.
SAFETY WARNINGS
To guarantee correct installation, proceed as follows:
1) The appliance should be installed by a qualified operator
2) The appliance should be installed in a panel in such a way as to guarantee that the
terminals are inaccessible after fitting
3) A protection device against over-currents should be installed in the electrical system,
upstream of the energy meter
4) Connect the instrument as shown in the alongside diagrams
5) Before touching the connector terminals make sure that the wires to be connected or
already connected to the instrument are not live
6) Do not power or connect the instrument if any part of it is damaged
8) The instrument must be installed and activated in compliance with current electric
systems standards.
Code Model Description
VN960100 Energy-230 LC Single-phase active energy meter
TECHNICAL SPECIFICATIONS
• Power supply: 230 V CA (-15%/+10%), 50/60 Hz
• Maximum power consumption: 4 VA
• Basic current: I = 15Ab
• Maximum current: I MAX = 22,5 A
• Starting current: ) 50 mA
• Current circuit consumption: < 2 VA
• Operating temperature: -10 ÷ +45 °C
• Storage temperature: -20 ÷ +60 °C
• Relative humidity: 10% ÷ 90% non-condensing
• Connection type: direct for current conductors
• Signaling leds: green = power on
red = flashing at 10Wh
• Accuracy: class 2 (EN 62053-21)
• Display: 6-digit mechanical counter
• Reading resolution: 0,1 kWh (full scale: 99999,9 kWh)
• Housing: 2 DIN, gray RAL 7035
• Protection degree: IP20/IP51 on the front
OPERATION
• In normal operation, the led is on and red led flashes in proportion to the green the
active power (flashing at 10Wh).
The meter counts the consumption of active power with a resolution of 0,1 kWh.
PHASE ERROR
• When the energy meter is turned on, a connection check-up is automatically carried out
to detect any connection errors: in case of improper connection, the and leds red green
flash alternate and the meter is locked.
Warning: to restore correct meter operation after an error reading has been
showed, switch the meter off, invert connections of voltage or current
and turn on again.
REFERENCE STANDARS
Conformity to EU directives:
2006/95/EC (Low Voltage)
2004/108/EC (EMC)
is declared with reference to the following harmonised standards:
EN 61010-1 EN 62053-21and
Dimensions
Connection
Description
(OHFWULFDOORDG
0D[$
9$&+]
7HUPLQDOEORFNIRUGLUHFW
FRQQHFWLRQRIPHWHULQJZLUHV
7RWDOHQHUJ\
*UHHQOHG
OLW SRZHURQ
5HGOHG
IODVK :K
Energy-230
kWh
15(22.5)A cl.2
230V~ 50/60Hz
ON 10Wh/imp
,
4
16000
Produkt Specifikationer
Mærke: | Vemer |
Kategori: | Måling |
Model: | Energy-230 LC |
Har du brug for hjælp?
Hvis du har brug for hjælp til Vemer Energy-230 LC stil et spørgsmål nedenfor, og andre brugere vil svare dig
Måling Vemer Manualer
27 Maj 2024
28 Februar 2024
17 April 2023
27 Marts 2023
9 Marts 2023
13 Oktober 2022
12 Oktober 2022
Måling Manualer
- Måling Bosch
- Måling SilverCrest
- Måling Hager
- Måling Owon
- Måling DeWalt
- Måling Extech
- Måling Silverline
- Måling IFM
- Måling Pioneer
- Måling Finder
- Måling Mitsubishi
- Måling Braun
- Måling Metrix
- Måling TFA
- Måling Garmin
- Måling Pyle
- Måling Güde
- Måling ABB
- Måling Hama
- Måling BENNING
- Måling Smartwares
- Måling Laserliner
- Måling Black And Decker
- Måling Trotec
- Måling Hilti
- Måling Soehnle
- Måling König
- Måling Powerfix
- Måling Flexa
- Måling Festo
- Måling Danfoss
- Måling Bresser
- Måling Alecto
- Måling Contec
- Måling VDO
- Måling Westfalia
- Måling Basetech
- Måling Voltcraft
- Måling Testboy
- Måling Velleman
- Måling FLIR
- Måling Perel
- Måling ORNO
- Måling Amprobe
- Måling Fluke
- Måling Stabila
- Måling Ridgid
- Måling Sun Joe
- Måling ADE
- Måling Projecta
- Måling Hazet
- Måling Park Tool
- Måling Pantone
- Måling Testo
- Måling GW Instek
- Måling Brandson
- Måling Etymotic
- Måling Cablexpert
- Måling Kopp
- Måling Steinberg
- Måling Eltako
- Måling Eastron
- Måling Vimar
- Måling Klein Tools
- Måling PeakTech
- Måling Uni-T
- Måling Joy-It
- Måling Kübler
- Måling Kern
- Måling Chauvin Arnoux
- Måling Megger
- Måling Peak
- Måling TDE Instruments
- Måling ClimeMET
- Måling Adwa
- Måling Gossen Metrawatt
- Måling Siglent
- Måling Hikmicro
- Måling PCE
- Måling Pico
- Måling Sonel
- Måling Murideo
- Måling Workzone
- Måling Sauter
- Måling Sikkens
- Måling X4-LIFE
- Måling Tru Components
- Måling Ebro
- Måling Berger & Schröter
- Måling Histor
- Måling PCE Instruments
- Måling Sanwa
- Måling MSW
- Måling Camille Bauer
- Måling Crelando
- Måling CSL
- Måling Stamos
- Måling Stelzner
- Måling Dranetz
- Måling Clare
- Måling Brookhuis
- Måling Crowcon
- Måling Intact
- Måling PQ Plus
- Måling DriveTest
- Måling Helvi
Nyeste Måling Manualer
16 December 2024
16 December 2024
15 December 2024
15 December 2024
15 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
13 December 2024