Vemer Energy-400 D PWRi Manual

Vemer Måling Energy-400 D PWRi

Læs nedenfor 📖 manual på dansk for Vemer Energy-400 D PWRi (2 sider) i kategorien Måling. Denne guide var nyttig for 24 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Mod. Energy-400 D PWRi
Energy-400 D PWRi
V3IS00418-011
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
65
87
45
60
72
L3
L2
L1
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
PWR/PWRi PWRi
PWRi P1 P2
S1 S2
S1 S2
I
I
L3
L2
L1
+
L3
L1
L2L3
N
L1
L2
+
PWR P1 P2
User Manual
THREE-PHASE ACTIVE ENERGY METER
Read all the instructions carefully
 Seriesof4-DINsizestaticmeterstoreadactiveenergyconsumptionin400Vthree-phase
systems
 –ENERGY-400DPWRwithcurrentinletthroughshunt
 –ENERGY-400DPWRiwithcurrentinletthrough
coils
,withgalvanicisolationbetweenthe
primaryandthesecondary
 Connectiontothepowersourceisthroughexternal
ATs
typex/5A
SAFETY WARNINGS
To guarantee correct installation, observe the following instructions:
1) The appliance must be installed by a qualified operator
2) The appliance must be installed in an electrical panel which, after installation,
leaves terminals inaccessible
3) A protection device against over-currents must be installed in the electrical system
upstream of the energy meter
4) Connect the instruments as shown in the diagrams opposite
5) Before making contact with terminals, ensure that conductors to be connected to
the appliance are not live
6) Do not power or connect the appliance if any part of it is damaged
Code Model Description
VE119400 Energy-400 D PWR Three-phaseactiveenergymeter
VE120200 Energy-400 D PWRi Insulatedthree-phaseactiveenergymeter
TECHNICAL SPECIFICATIONS
• Powersupply:3x230(400)VAC(-15%÷+10%),50/60Hz
• InputCurrent:In = 5A; Imax=6A
• Startupcurrent:15mA
• Maximumconsumption:3,5VAto400VAC
• Accuracy:class2(EN62053-21)
• Maximumloss: voltagecircuits<2.5VA
  powercircuits<2.5VA
• Galvanicisolationbetweenthevoltageinputsandthecurrentinputs(formodel
PWRi only
).
• AmperometricconnectionbyexternalATx/5A
• Display:bywayof7+5digitLCDdisplayunits
• Partialenergyresolution:xed1kWh
• Totalenergyresolution:xed1kWh
• Pulseproperties:Length:100ms±15%
  Voltage:9÷24VCC±10%
  Maximumoutputcurrent:20mA
• Signalingleds:green=poweron
  red=ashingat1/4kWh
  yellow=wrongconnection
• Optoinsulatedpulseoutputforremotemeterreading
• Operatingconditions:Temperature:-10÷+45°C
  Relativehumidity:10%÷90%noncondensing
• Storagetemperature:-25°C÷+70°C
• Enclosure:4DINsizes
• IngressprotectionratingIP:IP20/IP51onthefront
INSTALLATION
1) Onpoweringthedeviceup,selectthetransformationratioaccordingtotheexternalATx/5A
used.TheATsecondariesofthesolePWRimodelcanbeconnectedtotheearthingsystem
2) Thedevicemustbeconnectedasinthediagram,observingATenergydirection
3) Inorderfortheerrortostaywithinthedevice’sclasslimitsitisnecessarytousethecurrent
transformer in its linear operating range
PROGRAMMING EXTERNAL ATS (X/5A)
 SwitchthedeviceonwhileholdingdownthePRGkeyuntilthe
rmwareversionpageappears.
 PressthePRGkeytoaccessthepagereadingthedevice’sserialnumber
andthentheATsettingpage.
 TherstvaluedisplayedistheATprimary,accordingtothesettingsassignedtothedevice
untilthen.TosettheATvalue,selectthedigitthatneedstobechangedusingthePRGkey.
Whenthedigitselectedashes,changeitusingthearrowkeys and .Therangeof
availablevaluesisfrom0005to1000.ToexittheprogrammingmodeholdthePRGkeydown
foratleast3seconds.IfwhileintheATsettingwindow,nokeyispressedfor30seconds,this
willbeexitedandnochangewillbestored.
 Thedefaultfactorysettingis5/5A.
Note: When the AT setting is altered, then the partial energy meter is zeroed, whereas
the total energy meter remains unchanged.
OPERATION
• Whenthedeviceisturnedonthemainpageisdisplayed,representing
thetotalenergycountonthe7-digitupperblockandthepartialenergy
countonthe5-digitlowerblockThemeasuringresolutionforboth
metersis1kWh
• Todisplaythe
total
energycountonly,pressthe key:thismeter
cannot be set to zero
• Todisplaythe
partial
energyreading,pressthe keyagain:this
metercanalsobezeroedmanuallyanytimebyholdingthe“Prg”key
pressedformorethanfourseconds
• Toreturntothemainpagereadingbothmeters(totalandpartial
energy),pressthe keyagain
Pressthe keytoreverttheabovedescribedsequence.i.e.scrollthe
pagesbackward.
Note: The energy value reading refers to the complete three-phase system as an
algebraic addition (Etot
= E1
+E2+E3)
BACKLIGHTING
 Backlightingisenabledbydefault:itisswitchedoneachtimethekey
ispressedandstaysonfor30secondsafterthelastkeyispressed.In
ordertoenable/disablethebacklighting,gothe
main page
andhold
the“Prg”keypressedforatleast4seconds:theON/OFFbacklight
statuswillbedisplayedforacoupleofseconds,afterwhichthemain
pagewillreturn.
CONNECTION CHECKS
 Whenthedeviceisswitchedon,correctconnectiontocurrentand
voltageterminalsarechecked.Ifconnectionisincorrect,theyellow
LEDlightsupforthreeminutesandthengoesoff.
 Atthisstageandduringnormaloperationitispossibletoviewthe
detailedconnectionstatusbyholdingdownthePRGpush-buttonfrom
thetotalmeterpage:theATsettingpage(read-onlyatthisstage)and
theconnectionstatuspagewillthenbedisplayedsuccessively,withthe
possibleerrors(ifany).
 Incaseoferrorthefollowingmessagesmayappearonthedisplay:
 Connectionerrorononephase(L1inthiscase)
E1 is negative
 Connectionerrorontwophases(L1andL2inthiscase)
 E1andE2arenegative
 Connectionerroronthreephases
 E1,E2andE3arenegative
 Toexittheerrorreadingpage,pressthePRGkey.
 Ifnoerroristobereportedthe“noError“messagewillbereadfora
coupleofseconds.Thenthedevicewillresumenormaloperationfrom
thetotalenergypage.
Note: to restore correct meter operation after an error reading has been displayed,
switch the meter off, connect voltage and current as in the diagrams and then switch
the meter back on.
STANDARD REFERENCES
ConformitytotheEUdirectives:
2006/95/EC
(LowVoltage)
89/336/EEC
modiedby
92/31/EEC
and
93/68/EEC
(E.M.C.)
isdeclaredwithreferencetothefollowingharmonisedstandards:
Safety:
EN61010-1
Electromagnetic compatibility:
EN62052-11andEN62053-21
Dimensions
Connection diagram
Description
ON
PRG
Energy-400 D PWRi
3x230/400V~ 50/60 Hz
In/5(6)A~ cl.2
!
1/4 kWh
imp
Totalenergy
Signaling led
Partialenergy
Pulse output
blocks
Voltage lead
connectionblocks
Setting and
selectionkeys
Current lead
connectionblocks
Main page
Total meter
Partial meter
Backlighting status


Produkt Specifikationer

Mærke: Vemer
Kategori: Måling
Model: Energy-400 D PWRi

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer Energy-400 D PWRi stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Vemer Manualer

Måling Manualer

Nyeste Måling Manualer

Owon

Owon ADS3000 Manual

22 November 2024
Sauter

Sauter FA 20 Manual

21 November 2024
Sauter

Sauter TN EE Manual

21 November 2024
Sauter

Sauter FH 2K Manual

21 November 2024
Sauter

Sauter FA 300 Manual

21 November 2024
Sauter

Sauter FH 50K Manual

21 November 2024
Sauter

Sauter FK 25 Manual

21 November 2024
Sauter

Sauter FH 50 Manual

21 November 2024
Sauter

Sauter FH 5K Manual

21 November 2024
Sauter

Sauter FH 100K Manual

21 November 2024