Vemer Klima 2V Manual

Vemer Termostat Klima 2V

Læs nedenfor 📖 manual på dansk for Vemer Klima 2V (1 sider) i kategorien Termostat. Denne guide var nyttig for 5 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
User Manual
AMBIENT GAS MEMBRANE THERMOST
Read all the instruction carefully
This thermostats is designed to regulate the temperature in domestic and
industrial environments.
SAFETY WARNINGS
During installation and operation of the device, it is necessary to comply
with the following instructions:
1) The device must be installed by a skilled person, in strict compliance with
the connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) After installation, inaccessibility to the connection terminals without
appropriate tools must be granted
4) The device must be installed and activated in compliance with current
electric systems standards
5) Before accessing the connection terminals, verify that the leads are not live
Code Model Contact Functions
VE018800 KLIMA 2 NA -
VE019600 KLIMA 3 NA + NC -
VE020400 KLIMA 3L NA + NC Power on warning lamp
VE021200 KLIMA SI NA + NC ON/OFF + Power on warning lamp
VE022000 KLIMA IN NA + NC ON/OFF
VE023800 KLIMA SW NA + NC Summer/Winter
VE024600 KLIMA 2V NA + NC 2 speed + Summer/Winter/OFF
VE268900 KLIMA 3V NA + NC 3 speed + OFF
TECHNICAL SPECIFICATIONS
Free mounted single-pole mechanical thermostat
Setting range: +5 / +30°C
Differential: Δ ≤t C
Capacity of the contacts: 16(2,5)A 250V ~ for models KLIMA 2 e KLIMA 3
10(1,5)A 250V ~ for models KLIMA 3L, KLIMA SI, KLIMA IN,
KLIMA SW, KLIMA 2V, KLIMA 3V
Thermal gradient:C / 15 min.
Sensitive element: vapour expansion lung
Class I equipment
Protection degree: IP20
Type of action: 1B
Silver contacts 1000/1000
Break or switching contacts
Pollution degree: 2 (normal)
Voltage pulse: 4kV
Operating temperature: 0 ÷ 40°C
Operating humidity: 20 ÷ 90 %RH noncondensing
INSTALLATION
The thermostat should be tted at approximately 1.5 m from the ground avoid positioning
it near doors, windows, sources of heat and in places where there is too much or too little
ventilation.
1) The thermostat can be tted directly to the wall or to the ush-mounting box (centre
distance 60 mm).
2) Remove the knob, unscrew the screw of the cover and remove it
3) a) x the base to the wall
b) connect the thermostat earth by using the terminal marked with the earth symbol
c) follow the wiring diagram inside the cover; x the exible inseparable wires to the
relative screw terminals
d) replace the cover, screws and knob.
USER’S GUIDE
1) Set the temperature required by turning the knob;
2) To limit the setting eld:
a) Isolate the power supply line
b) Remove the knob
c) Insert the limit markers in the housing
under the knob (17°C ÷ 23°C
d) Return the knob to its housing.
REFERENCE STANDARDS
Conformity with EU directives: 2014/35/EU (LVD), 2014/30/EU (EMCD)
is declared with reference to the following standard: EN 60730-2-9
DIMENSIONS
ISCOM004-2105 Mod. KLIMA
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
83,7
76,5
82,9
60
60
31
39
CONNECTIONS
KLIMA 2
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3L
T
+°C
10(1,5)A 250V~
N
L
KLIMA IN
ON OFF
T
+°C
N
L
10(1,5)A
250V~
KLIMA SI
ON OFF
T
+°C
N
L
10(1,5)A
250V~
KLIMA SW
T
+°C
N
L
10(1,5)A
250V~
KLIMA 2V
OFF
I
II
T
+°C
N
L
10(1,5)A
250V~
KLIMA 3V
T
+°C
III
OFF
I
II
N
L
10(1,5)A
250V~
Note:
for “heating” operation
mode, remove the cable
terminal which is inside
the device from terminal
3 to teminal 2.
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.


Produkt Specifikationer

Mærke: Vemer
Kategori: Termostat
Model: Klima 2V

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer Klima 2V stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Vemer Manualer

Vemer

Vemer Iride 230 Manual

31 August 2024
Vemer

Vemer Chronos Key Manual

29 August 2024
Vemer

Vemer Tuo Wi-Fi Manual

8 August 2024
Vemer

Vemer ThermoPro Manual

8 August 2024
Vemer

Vemer Asso Wi-Fi Manual

6 August 2024
Vemer

Vemer Klima 2V Manual

31 Juli 2024
Vemer

Vemer Klima LCD Manual

30 Juli 2024
Vemer

Vemer Crono.X Manual

29 Juli 2024
Vemer

Vemer Aros Manual

28 Juli 2024

Termostat Manualer

Nyeste Termostat Manualer