DESCRIPTION
2
1User manual
WI-FI CHRONOTHERMOSTATS FOR RADIATORS
Read all the instructions carefully
Wi-Fi chronothermostat for installation on thermostatically-controlled valves with
weekly programming and battery power supply. The device is managed principally
using the app, which is available free of charge for iOS and Android systems.
Programming, switching on the system, changing of the operating settings and
the creation of new programs are all operations that can be performed easily and
from anywhere you are thanks to the integrated Wi-Fi module that connects the
device to the Internet through the home router. It comes with adapters that allow it
to be installed on the main thermostatic valves. ThermoPro Wi-Fi is an electronic
device is intended to operate in environments pollution degree 2 in accordance with
EN 60730-1 standard.
Code Model Descriprion
VE798100 ThermoPro Wi-Fi Weekly Wi-Fi chronothermostat for radiators
SAFETY WARNINGS
During installation and operation of the device, it is necessary to comply with the
following instructions:
1) The device must be installed by a qualified person.
2) The device must be installed and activated in compliance with current electric
systems standards.
3) Do not use the product for anything other than the indicated purpose.
4) Do not instal the device if any part of it is damaged.
TECHNICAL SPECIFICATIONS
Power supply: 2 x 1.5 V AA alkaline batteries (NOT rechargeable)
Battery life: 1 year (low battery indication)
Weekly programming via app
Programming resolution : 10 min
Regolation type: in the modulation of the valve opening according to the setpoint,
the mesured temperature and the characteristics of the environment
Compatible valve connections:
- compatible with the most part of valves with thread M30X1.5
- Danfoss RAV, RA, RAVL (with appropriate adapters)
Measurement accuracy: ± 1°C
Measured temperature resolution: 0,5°C
Temperature setting field: 8 ÷ 28°C
Wi-Fi operating frequency band: 2,4 GHz IEEE 802.11 b/g/n
Maximum transmitted Wi-Fi radiofrequency power: 18,3 dBm
Operating temperature: 0°C ÷ 50°C
Storage temperature: -20 ÷ 70°C
Operating humidity: 20% ÷ 90% non-condensing
Protection degree: IP20
Dimensions (LxHxP): 62x68x83 mm
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
ISCOM092-2407 Mod. ThermoPro Wi-Fi
Manuals
download
PDF
1 Union nut
2 Display with backlighting
3 Backlit touch keys
4 Cover for battery replacement
5 Adaptability accessories for
Danfoss RAV
6 Adaptability accessory for
Danfoss RA
7 Adaptability accessory for
Danfoss RAVL
5DISPOSAL OF BATTERIES
It is necessary to remove the batteries before the instrument is scrapped.
In case of replacement, dispose of the batteries in the
appropriate places separate waste collection containers.
REFERENCE STANDARDS
07-2024
EU Declaration of Conformity: Vemer declares that the device complies with EU
Directive 2014/53/EU (red) with reference to the following standards:
• EN 62311 • EN 60730-1 • ETSI EN 301 489-1 • ETSI EN 301 489-17
• ETSI EN 300 328
The full text of the EU Declaration of Conformity is available at the Internet address
www.vemer.it
4PRELIMINARY OPERATIONS AND WARNINGS FOR THE CORRECT
CONNECTION OF THE DEVICE TO A WI-FI NETWORK
WARNINGS
The use of the devide via the ThermoPro Wi-Fi APP must be carried out
in the presence of a Wi-Fi network connected to the Interne
and there are no browsing restrictions.
Make sure that the Router and/or the Wi-Fi Access Point are correctly switched
on and at a distance such as to guarantee a stable communication signal
with the device.
Install and connect the device according the installation instructions given in this
manual.
Check that:
1. the 2.4 GHz frequency band is also enabled in the Router settings (if the Router only
supports the 5 GHz frequency range, it will not be possible to operate the device;
for further information see the user instructions of your Router)
2. the smartphone used for configuration is connected to the same Wi-Fi network
to which the device is connected
3. position detection (GPS) of your smartphone is active and the consent to the
ThermoPro Wi-Fi App to be able to identify the position (GPS) of the device is enabled
(adapt the settings on the smartphone such as to be able to perform this tracking;
for further information see the instructions of your smartphone)
Create a Vemer account by installing the app on your smartphone ThermoPro Wi-Fi
and starting the registration procedure by pressing the “REGISTER NOW” button
To manage the device via the application, start the device configuration procedure
by pressing the on the Home page and +” button carefully following the
step-by-step instructions in the guided procedure.
Note: During setup device a message may be displayed on the phone informing
that are not connected to the Internet. Confirm this message to stay
connected to the device and continue with the setup.
6REMOTE CONTROL CONFIGURATION
KEYBOARD OPERATION
The keys on the device allow you to carry out the operations described in the table:
KEY Pressure type Function
Short pressure Increase of the temperature set point in local operation
Short pressure Reduction of the temperature set point in local operation
Long pressure at the same time (>3sec) Lock (or unlock) keyboard
Long pressure at the same time (>3sec) (when the
Ad icon is present on the display) Start adaptation procedure to the valve
10
DISPLAY SIGNALS
Based on the display signals described in the table, it is possible to understand the operating status of the device:
SIGNALING Operating status Action
AP Remote control setup phase Proceed with device conguration via App
Ad Necessary adaptation Proceed with the adaptation procedure (Long pressure at the same time (>3sec) of keys and )
bt Low battery Replace the batteries
C1 Incorrect Wi-Fi password entered Repeat the setup procedure
The WiFi signal strength is too weak Improve the Wi-Fi signal strength in the environment where the device is installed
C2
The WiFi password has been changed Repeat the setup procedure
Interruption of the existing wireless connection Improve the Wi-Fi signal strength in the environment where the device is installed
Set-up WiFi connection was temporarily interrupted Check the correct functioning of the Router/Access Point
C3 WiFi connection without Internet access Check the correct functioning of the Router/Access Point
E1 No adaptation possible Install device correctly on the radiator
E2 Valve stroke too short Open and close the valve plunger by hand several times
Battery charge too low Replace the batteries
E3 No valve movement possible Make sure that the valve plunger can move freely
Fixed on (when the display is on) Normal operation (device connected to server)
Flashing (when the display is on) Connection to server is established
Spento (when the display is on) No Wi-Fi connection
11
MOUNTING
3
Open the current thermostatic head completely.
Loosen the fastening and pull the thermostatic head off the radiator.
Place the ThermoPro WiFi on the radiator by turning the union nut clockwise.
If necessary, use the adapter according to the type of valve present on the
radiator.
Open the battery compartment cover and insert the batteries
pay attention to the correct polarity and do not use rechargeable batteries.
LOCAL OPERATION
7
When the ThermoPro Wi-Fi keyboard is operated, the device activates local operation. In this way it is possible to set a different setpoint than that forecast in the programming
carried out by the app. Local operation is automatically stopped at the first setpoint change sent by the app (manually or by program).
It is possible to limit or disable local operation by locking the keyboard which can be activated from the application or by pressing and holding the and keys
simultaneously.
Note: From the application it is possible to activate the function which disables the operation of the keys, “Key Lock Plus” useful if you want to have control of the device
only from the app.
DEVICE RESET
Perform a reset to delete the settings entered and restore
the device to the factory default or in case of replacement
of the Router/Access Point of the home network or if it is
necessary to change the network settings entered in the
device (SSID network name or password).
To reset, open the battery compartment cover and hold
down the reset button in the battery compartment until
the number 10 appears on the device display.
5 6 7
8
DEVICE OPERATION
The device manages the functions described in the table which can be set via the application:
9
Function Description
Programs ON (AUTO)
Allows to use the device as a chronothermostat, the temperature is regulated following the prole” of the program created and set.
In this mode is possible to temporarily modify the set point forecast in the programming by acting on the device keyboard or with the appropriate cursor in the app.
The device resumes normal operation at the rst change in the set point forecast by the set program.
Programs OFF (MANU) Allows to use the device as a thermostat, the adjustment occurs according to the temperature set manually from the device keyboard or with the appropriate slider
in the app.
Holiday Allows to set a temperature of your choice for a period of time delimited by a start and end point.
When the set time expires the device resumes normal operation. nto.
Ventilation detection Allows to automatically close the heating valve to save energy if a sudden drop in temperature is detected due to an open window.
In this mode it is possible to set the sensitivity of temperature drop detection and the valve closing duration.
Oset Allows to introduce a temperature adjustment in particular installation conditions if the temperature measured by the device deviates from the average temperature present
in the room.
Rotate display Allows to rotate the device display by 180° to obtain an optimal reading based on the positioning of the radiator valve.
Antifreeze protection Function always active. Avoids the risk of the system freezing when the temperature drops belowC.
Llimescale protection Function always active. Prevent radiator valves from calcifying by carrying out an opening and closing cycle of the valve once a week (Friday at 11:00)
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included wit h other general waste
at the end of it s working lif e.
The user must take the worn product to a sorted wast e center,
or return it t o the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if t hey measure less than 25 cm.
An ef ficient sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent
recycling, helps avoid the potential negative effects on the environment and people’s health,
and encourages the re-use and/or recycling of the construction materials.
3
1
2
4


Produkt Specifikationer

Mærke: Vemer
Kategori: Termostat
Model: ThermoPro Wi-Fi

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer ThermoPro Wi-Fi stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Vemer Manualer

Vemer

Vemer Iride 230 Manual

31 August 2024
Vemer

Vemer Chronos Key Manual

29 August 2024
Vemer

Vemer Tuo Wi-Fi Manual

8 August 2024
Vemer

Vemer ThermoPro Manual

8 August 2024
Vemer

Vemer Asso Wi-Fi Manual

6 August 2024
Vemer

Vemer Klima 2V Manual

31 Juli 2024
Vemer

Vemer Klima LCD Manual

30 Juli 2024
Vemer

Vemer Crono.X Manual

29 Juli 2024
Vemer

Vemer Aros Manual

28 Juli 2024

Termostat Manualer

Nyeste Termostat Manualer