Optical Smoke Alarm
Art.no 36-6213 Model GS506G
Please read theentire instruction manual before using theproduct and then
save it for future reference. Wereserve theright for any errors in text or images
and any necessary changes made to technicaldata. Ifyou have any questions
concerning technical problems please contact our Customer Services.
Fire safety
Preventative measures:
• Store any matches and lighters in alocked room out of children’sreach.
• Never empty theashes from ash trays, stoves and grills into waste bins
until theashes have completely cooled. Itis advisable to let them cool
overnight before disposing ofthem. Sootand ashes from stoves and
fireplaces should be collected in metal buckets fitted withlids. Always
place receptacles holding hot ashes on afireproof surface.
• Never leave naked flames such as candles unattended. Onlyuse non-
flammable candle holders and candlesticks.
• Make sure that no sparks can escape from your wood-burning stove or
fireplace and ensure that thefire has died before going tobed.
• Do not store or handle combustible liquids/substances close to sources
ofheat.
• Replace any faulty electrical plug or wiring. Makesure that thecorrect
type of fuses and circuit breakers are used in your consumerunit.
• Remember to switch off your TV, computer and other appliances using
thepower switch. Remote controls don’t switch appliances off completely.
• Do not place combustible materials and objects next to electrical heating
appliances. Avoidcontrolling electrical heaters with timers or any kind of
remote control device. Bearin mind that acombustible material might
have been placed on or next to anelectrical heating appliance while it
was switched off without your knowledge.
• It is important that chimneys and flues are cleaned regularly to prevent
chimneyfires.
• Further information about fire safety in thehome can be obtained from
theDepartment for Communities and Local Governmenthttps://www.
gov.uk/government/organisations/department-for-communities-
and-local-government if you should need tips and advice about how to
protect your home and family fromfire.
Fire safety checks:
• Check thecondition of your fire extinguishers and make sure that
everyone in your household knows how to usethem.
• Draw up asafe plan of escape from your premises in case of emergency.
Makesure that there are alternative escape routes, such as windows. Make
sure that there is aladder or rope as analternative in case stairs are blocked.
• Practise your escape plan to make sure that itworks. Decide upon
anassembly point to gather in anemergency.
• Keep bedroom doors closed during thenight. Aclosed door can keep
thefire at bay long enough for you to make your escape through awindow.
If afire breaksout:
• If afire alarm goes off, keep calm but act quickly.
• Wake everyone up and make sure that they leave thebuilding according
to your escapeplan. Follow your escapeplan.
• Carefully feel doors with theback of your hand before opening them – if
they are hot, don’t openthem. Tryto find analternative escaperoute.
Ifyou have to escape through smoke, crawl on your hands and knees
under thesmoke. Don’t waste time rescuing valuables.
• If possible, close doors and windows to contain theblaze.
• If thefire is small try to extinguish/contain it with awater hose, fire
extinguisher or fire blanket. Firstmake sure that you have ameans of
escape before tackling thefire. Getout as quickly as possible if you realise
that you can’t extinguish thefire.
• Call as soon as you are free of thebuilding, call from aneighbour’s 999
house if you don’t have aphone.
• Make sure that no-one re-enters thebuilding, wait for thefire brigade.
Positioning the smoke alarm
• Smoke alarms should be positioned in themiddle of theceiling of aroom
at thehighest point, or at thehighest point of thehallway, staircase or
landing. Smokeand fumes will rise, accumulate on theceiling and enter
thesmoke alarm from thetop.
• All bedrooms, corridors/escape routes should be equipped with smoke
alarms. Other rooms should also be equipped for comprehensive
protection.
• Corridors up to 3 m wide: The first smoke alarm should be place at a max
distance of 7.5 m from the end of the corridor. The max distance between
two smoke alarms should be 15 m.
• Corridors less than 1 m wide: The first smoke alarm should be placed at
a max distance of 7.5 m from the end of the corridor. The smoke alarm
should be mounted in the middle of the ceiling. In these cases, the rule of
keeping a 0.5 m distance to a wall cannot be met.
• Exterior corridors and similar: If the total length and width exceed 16 m²,
an extra smoke alarm should be mounted in the highest-lying area.
Installation
1. Remove thebaseplate by turning it anti-
clockwise.
2. Markout theposition of themounting holes
on thewall using thebaseplate as atemplate.
Screwthebaseplate into place using
theincluded screws. Forconcrete ceilings it
might be necessary to drill Ø 5 mm holes and
insert theincluded wall plugs before screwing
on thealarm.
3. Insert thebattery and connect theterminals.
• Pushing in thetest button will test all theessential functions of thesmoke
alarm and check that thebatteryworks.
• Thetest button simulates smoke entering thesmoke alarm,i.e. thetest
button has thesame effect as realsmoke.
• It is crucial that thesmoke be tested regularly and often, at least once
amonth. Forexample in conjunction with house cleaning, or after along
holiday away fromhome.
• Thesmoke alarm will only alert you when thebattery islow. Ifthere is any
other technical fault with thesmoke alarm it will not alert you to thisfact.
Thetest button on theother hand tests thebattery and all theessential
functions.
• The smoke alarm must be replaced if it does not emit 3 short audible
signals when the test button is pressed in for 5 sec.
Warning: Donot test thealarm close to naked flames, these can damaged
thealarm and are dangerous. Wedo not recommend that you test thealarm
using smoke as results can be misleading if thecorrect test equipment is
notused.
The smoke alarm shall be replaced after 10 years
Smoke alarms shall be replaced after 10 years of service. Theexpiry date
should be printed on theratinglabel.
Care and maintenance
• Asmoke alarm which is dirty on theinside is more sensitive and often
goes off without reason.
• Theoutside of thesmoke alarm should be wiped clean with adamp cloth
and vacuumed carefully with asoft brush nozzle.
• Clean the smoke alarm by vacuuming it at least once a year. Test the
smoke alarm according to the instructions in the owner’s manual. Check
that all the inlets are unblocked and that the smoke alarm is not damaged
in any way. A damaged smoke alarm must be replaced.
Responsible disposal
This symbol indicates that this product should not be disposed of with
general householdwaste. Thisapplies throughout theentire EU. Inorder
to prevent any harm to theenvironment or health hazards caused
by incorrect waste disposal, theproduct must be handed in for
recycling so that thematerial can be disposed of in aresponsible
manner. Whenrecycling your product, take it to your local collection
facility or contact theplace of purchase. Theywill ensure that
theproduct is disposed of in anenvironmentally soundmanner.
Specifications
Power supply 9 V Alkaline battery* (lifespan 1 year)
Currentdraw Standby <10 µA, alarm <30 mA
Loudness >85 dB at adistance of 3 m
Maximum humidity 90 % RH
Temperaturerange 0–45 °C
Alarm sensitivity 0.10–0.16 dB/m
Servicelife Thesmoke alarm shall be replaced after 10years.
Theexpiry date should be printed on theratinglabel.
* Replace using the following batteries only: Zinc-carbon: Gold Peak 1604S (1-year
estimated lifetime). Alkaline: Gold Peak 1604A, Raymax 6LR61, Duracell MN1604
(5-year estimated lifetime). Lithium: EVE CR9-V (10-year estimated lifetime). (Using
unsuitable battery types and incorrect battery insertion pose an explosion risk. Only use
a battery of the same or equivalent type when replacing.)
• Place at least 0.5 m from
a wall or other obstacle. If
partition walls, furniture or
similar objects reach up to
ceiling level, then each of
these divided areas must
have their own separate
smoke alarm.
• Sloped ceiling placement, 50–
100cm from thepeak.
• Several smoke alarms must be
mounted at various heights for
ceilings exceeding 6 m in height.
• If ceiling beams or similar protrude
more than 0.2 m from the ceiling
and the area between the beams
is greater than 36 m², then the
smoke alarm should be mounted
in this area between the beams. If
beams protrude less than 0.2 m,
then the smoke alarm can either
be mounted on the ceiling or the
beam itself.
Thegrey zone is deadair. Donot
install thesmoke alarm in thisarea.
Do NOT place thesmoke alarm in thefollowing places:
• Do not place thesmoke alarm in thekitchen, where theventilation ispoor.
Smokeand vapours from cooking and baking could set thealarmoff.
• Do not place thesmoke alarm close to extractor fans or airvents.
Smokecan be drawn to these places instead of to thesmokealarm.
• Do not place asmoke alarm in agarage. Fumesfrom thecar exhaust
could set thealarmoff.
• Do not place thesmoke alarm in areas with high humidity or areas that
experience large changes in temperature. Thesmoke alarm should not be
placed in areas with temperatures below +5 °C or above +40 °C.
• Thesmoke alarm must not be paintedover.Note:
4. Twistthesmoke alarm back onto thebaseplate.
5. Holdin thetest button to test thesmokealarm. Referto thesection
Testing thesmokealarm.
Changing the battery
The included battery has an approximate 1-year lifespan. Roughly amonth
before thebattery dies, thealarm will emit short audible signals and thered
LED will flash approximately every 30 seconds. Should this occur, it is time to
change thebattery.
1. Remove thealarm from thebaseplate by turning it clockwise.
2. Remove theold battery and connect theterminal leads to thenew battery*.
3. Insert thenew battery into thebattery holder.
4. Holdin thetest button for at least 5 seconds to make sure that thesmoke
alarmworks. Referto thesection Testing thesmoke alarm.
Safety information
• If thebedrooms are located in different parts of thehouse, asmoke alarm
should be placed in each bedroom.
• If thehouse has several floors, asmoke alarm should be placed on
everyfloor.
• Thesooner your family is warned of afire, themore chance you have of
saving yourselves and your property.
• Smoke alarms should be positioned in themiddle of theceiling of aroom
at thehighest point, or at thehighest point of thehallway, staircase or landing.
• Themore smoke alarms you have – thesafer you’llbe. Makesure that
you can hear thesmoke alarms from your bedroom.
• Smoke alarms should normally not be more than 10–12 mapart.
Themaximum floor space area that one smoke alarm can protect is 60 m².
• Don’t put alarms in or near kitchens or garages where smoke or exhaust
fumes can set them off by accident. Neither is it advisable to fit smoke
alarms in humid rooms or close tofans. Notin agricultural buildings either.
• Themajority of household fires start in thekitchen. Asmoke alarm should
therefore be placed in theroom next to thekitchen to provide as early as
warning as possible.
• Factors which can increase theneed for having asmoke alarmare:
Closed doors, different ceiling heights, long distances or other obstacles
that might prevent or delay smoke from reaching thesmokealarm.
• The smoke alarm must be mounted in a safe manner to ensure that it
does not fall and cause injury to someone. It may be difficult to mount
the smoke alarm to plasterboard ceilings or similar types of ceilings.
• The battery must not be subjected to fire, direct sunlight or high
temperatures
• Thesmoke alarm must not be paintedover.Note:
Testing the smoke alarm
Test thesmoke alarm as follows: Pressand hold in thetest button for at
least 5 seconds. Thealarm will emit 3 short beeps followed by apause
of 1.5seconds in acontinuous cycle for as long as thebutton is heldin.
Thered LED will flash acouple of times aminute.
For declaration of performance
visit www.clasohlson.com
• Horizontal/slanted ceilings: Smoke alarms should be placed at least 0.5
and a maximum of 1 m away from the ceiling’s highest point on ceilings
which have a horizontal portion and a slanted portion with a slant of over
20º. The smoke alarm should be mounted on the slanted portion of the
ceiling if the horizontal portion is less than 1 m wide. The smoke alarm
should be mounted in the middle of the horizontal portion if this portion is
more than 1 m wide.
Produkt Specifikationer
Mærke: | Cotech |
Kategori: | Røgalarm |
Model: | GS506G |
Har du brug for hjælp?
Hvis du har brug for hjælp til Cotech GS506G stil et spørgsmål nedenfor, og andre brugere vil svare dig
Røgalarm Cotech Manualer
15 Maj 2024
2 Februar 2024
Røgalarm Manualer
- Røgalarm Bosch
- Røgalarm Denver
- Røgalarm Siemens
- Røgalarm Hager
- Røgalarm Ei Electronics
- Røgalarm Emos
- Røgalarm Grundig
- Røgalarm Pyle
- Røgalarm Nedis
- Røgalarm Abus
- Røgalarm Hama
- Røgalarm Clas Ohlson
- Røgalarm Smartwares
- Røgalarm Trust
- Røgalarm Busch-Jaeger
- Røgalarm Honeywell
- Røgalarm Bavaria
- Røgalarm König
- Røgalarm FireAngel
- Røgalarm Elro
- Røgalarm Yale
- Røgalarm Nest
- Røgalarm Mercury
- Røgalarm Alecto
- Røgalarm Flamingo
- Røgalarm Olympia
- Røgalarm HQ
- Røgalarm Housegard
- Røgalarm Schneider
- Røgalarm Marmitek
- Røgalarm GEV
- Røgalarm JUNG
- Røgalarm ORNO
- Røgalarm Netatmo
- Røgalarm M-e
- Røgalarm EQ3
- Røgalarm Calex
- Røgalarm Mobeye
- Røgalarm Brennenstuhl
- Røgalarm Electia
- Røgalarm Lanberg
- Røgalarm X-Sense
- Røgalarm Esylux
- Røgalarm Kidde
- Røgalarm Steren
- Røgalarm Ferguson
- Røgalarm Pyrexx
- Røgalarm Sygonix
- Røgalarm Heatit
- Røgalarm STI
- Røgalarm Frient
Nyeste Røgalarm Manualer
26 September 2024
17 September 2024
27 August 2024
27 August 2024
21 August 2024
21 August 2024
26 Juli 2024
26 Juli 2024
24 Juli 2024
14 Juli 2024