Shelly Plus Manual


Læs nedenfor 📖 manual på dansk for Shelly Plus (3 sider) i kategorien Smart hjem. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
EN
USER AND SAFETY GUIDE
SHELLY PLUS ADD-ON
Read before use
This document contains important technical and safety
information about the device, its safety use and instal-
lation.
CAUTION! Before beginning the installation, please read
this guide and any other documents accompanying the de-
vice carefully and completely. Failure to follow the installa-
tion procedures could lead to malfunction, danger to your
health and life, violation of the law or refusal of legal and/
or commercial guarantee (if any). Allterco Robotics EOOD
is not responsible for any loss or damage in case of incor-
rect installation or improper operation of this device due to
failure of following the user and safety instructions in this
guide.
Product Introduction
Shelly Plus Add-on (the Device) is a galvanically isolated
sensor interface to the Shelly Plus devices.
Legend
Device terminals:
VCC: Sensor power supply terminals
DATA: 1-Wire data terminals
GND: Ground terminals
ANALOG IN: Analog input
DIGITAL IN: Digital input
VREF OUT: Reference voltage output
VREF+R1 OUT: Reference voltage through a pull-up re-
sistor* output
External sensor pins:
VCC/VDD: Sensor power supply pins
DATA/DQ: Sensor data pins
GND: Ground pins
* For passive devices that need it to form a voltage divider.
Installation Instructions
CAUTION! Danger of electrocution. Mounting/installa-
tion of the Device to the power grid has to be performed
with caution, by a qualied electrician.
CAUTION! Danger of electrocution. Every change in the
connections has to be done after ensuring there is no volt-
age present at the Device terminals.
CAUTION! Use the Device only with a power grid and
appliances which comply with all applicable regulations. A
short circuit in the power grid or any appliance connected to
the Device may damage the Device.
CAUTION! Do not connect the Device to appliances ex-
ceeding the given max load!
CAUTION! Connect the Device only in the way shown in
these instructions. Any other method could cause damage
and/or injury.
CAUTION! Do not install the Device where it can get wet.
If you are installing the Shelly Plus Add-on to a Shelly Plus
device that is already connected to the power grid, check
that the breakers are turned off and there is no voltage on
the terminals of the Shelly Plus device you are attaching the
Shelly Plus Add-on to. This can be done with a phase tester
or multimeter. When you are sure that there is no voltage,
you can proceed to installing the Shelly Plus Add-on.
Attach the Shelly Plus Add-on to the Shelly Plus device as
shown on Fig. 3
CAUTION! Be very careful not to bend the Device header
pins (C) when inserting them to the Shelly Plus device head-
er connector (D).
Make sure the brackets (A) lock on the Shelly Plus device
hooks (B) and then proceed to the Device wiring.
Connect one digital humidity and temperature sensor
DHT22 as shown on Fig. 1 A or up to 5 digital temperature
sensors DS18B20 as shown on Fig. 1 B.
CAUTION! Do not connect more than one DHT22 sensor
or a combination of DHT22 and DS18B20 sensors.
DE
BENUTZER- UND
SICHERHEITSHANDBUCH
SHELLY PLUS ADD-ON
Bitte vor Gebrauch durchlesen
Dieses Dokument enthält wichtige technische und sicher-
heitstechnische Informationen über das Gerät und seine
sichere Verwendung und Installation.
ACHTUNG! Bevor Sie mit der Installation beginnen, lesen
Sie bitte die Begleitdokumentation sorgfältig und vollstän-
dig durch. Die Nichtbeachtung der empfohlenen Verfahren
kann zu Fehlfunktionen, Lebensgefahr oder Gesetzesverstö-
ßen führen. Allterco Robotics EOOD haftet nicht für Verluste
oder Schäden im Falle einer falschen Installation oder Be-
dienung dieses Geräts.
Produktvorstellung
Shelly Plus Add-on (das Gerät) ist eine galvanisch getrenn-
te Sensorschnittstelle zu den Shelly Plus Geräten.
Legende
Geräteanschlüsse:
VCC: Klemmenr Stromversorgung
DATA: Klemmen für 1 Adriges Datenkabel
GND: Klemmen für Massekabel
ANALOG IN: Analoger Eingang
DIGITAL IN: Digitaler Eingang
VREF OUT: Ausgang der Referenzspannung
VREF+R1 OUT: Referenzspannung über einen Pull-up-
Widerstand* Ausgang
Externe Sensoranschlüsse:
VCC/VDD: Klemmen für Stromversorgung
DATA/DQ: Klemmen für Datenkabel
GND: Klemmen für Massekabel
* Für passive Geräte, die einen Spannungsteiler benötigen
Instructions d’installation
VORSICHT! Gefahr eines Stromschlages. Die Montage/
Installation des Geräts an das Stromnetz muss von einem
qualizierten Elektriker mit Vorsicht durchgeführt werden!
VORSICHT! Es besteht Stromschlaggefahr. Bei jeder Än-
derung der Anschlüsse muss sichergestellt werden, dass an
den Klemmen des Geräts keine Spannung anliegt!
VORSICHT! Verwenden Sie das Gerät nur mit einem
Stromnetz und Geräten, die allen geltenden Vorschriften
entsprechen. Ein Kurzschluss im Stromnetz oder in einem
an das Gerät angeschlossenen Gerätes kann dieses be-
schädigen!
VORSICHT! Schließen Sie das Gerät nicht an Geräte an,
die die angegebene Höchstlast überschreiten!
VORSICHT! Schließen Sie das Gerät nur auf die in dieser
Anleitung beschriebene Weise an. Jede andere Methode
kann zu Schäden und/oder Verletzungen führen!
VORSICHT! Installieren Sie das Gerät nicht an einem Ort,
an dem es nass werden kann!
Wenn Sie das Shelly Plus Add-on an einem Shelly Plus Ge-
rät anbringen, das bereits mit dem Stromnetz verbunden
ist, vergewissern Sie sich, dass die Sicherungen ausge-
schaltet sind und keine Spannung an dem Gerät anliegt,
an dem Sie das Shelly Plus Add-on anbringen wollen.
Verwenden Sie dazu ein Phasenprüfgerät oder ein Multi-
meter. Wenn Sie sicher sind, dass keine Spannung mehr
vorhanden ist, nnen Sie mit der Installation des Shelly
Plus Add-ons fortfahren.
Befestigen Sie das Shelly Plus Add-on am Shelly Plus Gerät
wie in Abb. 3 gezeigt.
ACHTUNG! Achten Sie darauf, dass Sie die Pins des Ge-
rätekopfes (C) nicht verbiegen, wenn Sie sie in den Shelly
Plus Gerätekopfstecker (D) stecken.
Vergewissern Sie sich, dass die Halterungen (A) an den
Shelly Plus Gerätehaken (B) einrasten, und fahren Sie dann
mit der Geräteverkabelung fort.
Verbinden Sie einen digitalen Feuchtigkeits- und Tempera-
IT
GUIDA ALLUSO E ALLA SICUREZZA
SHELLY PLUS ADD-ON
Leggere prima dell‘uso
Questo documento contiene importanti informazioni
tecniche e di sicurezza sul dispositivo e sul suo uso e in-
stallazione in sicurezza.
ATTENZIONE! Prima di iniziare l’installazione leggere at-
tentamente e completamente la documentazione allegata.
La mancata osservanza delle procedure consigliate potreb-
be portare a malfunzionamenti, pericolo per la vita o violazi-
one della legge. Allterco Robotics EOOD non è responsabile
per eventuali perdite o danni in caso di installazione o funzi-
onamento errati di questo dispositivo.
Introduzione al prodotto
Shelly Plus Addon (il dispositivo) è un‘interfaccia sensore
isolata galvanicamente per i dispositivi Shelly Plus.
Legenda
Terminali del dispositivo:
VCC: Morsetti di alimentazione del sensore
DATI: Terminali dati a 1 lo
GND: terminali di terra
ANALOG IN: Ingresso analogico
INGRESSO DIGITALE: Ingresso digitale
VREF OUT: Uscita tensione di riferimento
VREF+R1 OUT: tensione di riferimento attraverso un‘us-
cita resistore pull-up*
Pin del sensore esterno:
VCC/VDD: pin di alimentazione del sensore
DATA/DQ: pin dati del sensore
GND: pin di messa a terra
* Per dispositivi passivi che ne hanno bisogno per formare
un partitore di tensione.
Istruzioni per l‘installazione
ATTENZIONE! Pericolo di folgorazione. Il montaggio/
installazione del dispositivo alla rete elettrica deve essere
eseguito con cautela da un elettricista qualicato.
ATTENZIONE! Pericolo di folgorazione. Ogni modica
dei collegamenti deve essere effettuata dopo essersi ass-
icurati che non ci sia tensione ai morsetti dell‘apparecchio.
ATTENZIONE! Utilizzare l‘apparecchio solo con una
rete elettrica e con apparecchi conformi a tutte le norme
vigenti. Un cortocircuito nella rete elettrica o in qualsiasi
apparecchio collegato all‘apparecchio può danneggiare
l‘apparecchio.
ATTENZIONE! Non collegare l‘apparecchio ad apparec-
chi che superano il carico massimo indicato!
ATTENZIONE! Collegare l‘apparecchio solo nel modo in-
dicato in queste istruzioni. Qualsiasi altro metodo potrebbe
causare danni e/o lesioni.
ATTENZIONE! Non installare il dispositivo in un luogo
che possa bagnarsi.
Se stai installando Shelly Plus Addon su un dispositivo
Shelly Plus che è già collegato alla rete elettrica, controlla
che gli interruttori siano spenti e che non ci sia tensione sui
terminali del dispositivo Shelly Plus a cui stai collegando
Shelly Plus Addon . Questo può essere fatto con un tester
di fase o un multimetro. Quando sei sicuro che non ci sia
tensione, puoi procedere all‘installazione del componente
aggiuntivo Shelly Plus.
Collegare lo Shelly Plus Addon al dispositivo Shelly Plus
come mostrato in Fig. 3
ATTENZIONE! Fare molta attenzione a non piegare i pin
dell‘intestazione del dispositivo (C) quando li si inseriscono
nel connettore dell‘intestazione del dispositivo Shelly Plus
(D).
Assicurarsi che le staffe (A) si blocchino sui ganci del dis-
positivo Shelly Plus (B) e quindi procedere al cablaggio del
dispositivo.
Collegare un sensore digitale di umidi e temperatura
Connect a 10 potentiometer as shown on Fig. 2 A for
smooth analog readings or a thermistor with 10 nomi-
nal resistance and β=4000 K as shown on Fig. 2 B for ana-
log temperature measurement.
You can also measure the voltage of an external source
within the 0 to 10 VDC range. The voltage source internal
resistance should be less than 10 for optimal perfor-
mance.
The Device also provides interface to an auxiliary digital
signal though its digital input. Connect a switch/button, a
relay or an electronic device as shown on Fig. 2.
If the Shelly Plus device, which the Shelly Plus Add-on is at-
tached to, has not been connected to the power grid, install
it following its user and safety guide.
Specications
Mounting: Attached to a Shelly Plus device
Dimensions (HxWxD): 37x42x15 mm
Working temperature: -20°C to 40°C
Max. altitude: 2000 m
Power supply: 3.3 VDC (from Shelly plus device)
Electrical consumption: < 0.5 W (without sensors)
Analog input range: 0 - 10 VDC
Analog input report threshold: 0.1 VDC *
Analog input sampling rate: 1 Hz
Analog measurement accuracy: better than 5%
Digital input levels: -15 V to 0.5 V (True) /
2.5 V to 15 V (False) **
Screw terminals max. torque: 0.1 Nm
Wire cross section: max. 1 mm²
Wire strip length: 4.5 mm
*Can be congured in the analog input settings
**Logic can be inverted in the digital input settings
Declaration of conformity
Hereby, Allterco Robotics EOOD declares that the equip-
ment type Shelly Plus Add-on is in compliance with Direc-
tive 2014/30/ЕU, 2014/53/EU, 2014/35/EU. The full text of
the EU declaration of conformity is available at the follow-
ing internet address:
www.shelly.cloud/knowledge-base/devices/shelly-plus-add-on/
Manufacturer: Allterco Robotics EOOD
Address: Bulgaria, Soa, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Web: https://www.shelly.cloud
Changes in the contact data are published by the Manu-
facturer at the ocial website. https://www.shelly.cloud
All rights to trademark Shelly® and other intellectual rights
associated with this Device belong to Allterco Robotics
EOOD.
tursensor DHT22 wie in Abb. 1 A dargestellt oder bis zu
5 digitale Temperatursensoren DS18B20 wie in Abb. 1 B
dargestellt.
CAUTION! Verbinden Sie nicht mehr als einen DHT22-
Sensor oder eine Kombination aus DHT22- und DS18B20-
Sensoren.
Verbinden Sie ein 10 kΩ-Potentiometer wie in Abb. 2 A dar-
gestellt für glatte analoge Messwerte oder einen Thermis-
tor mit 10 kΩ Nennwiderstand und β=4000 K wie in Abb. 2
B dargestellt für analoge Temperaturmessung.
Sie können auch die Spannung einer externen Quelle im Be-
reich von 0 bis 10 VDC messen. Der Innenwiderstand der
Spannungsquelle sollte für eine optimale Leistung weniger
als 10 kΩ betragen.
Das Gerät bietet auch eine Schnittstelle r ein digitales
Hilfssignal über seinen digitalen Eingang.
Verbinden Sie einen Schalter/Taster, ein Relais oder ein
elektronisches Gerät wie in Abb. 2 gezeigt.
Wenn das Shelly Plus Gerät, an das der Shelly Plus Add-on
angeschlossen ist, noch nicht mit dem Stromnetz verbun-
den ist, installieren Sie es gemäß der Benutzer- und Sicher-
heitsanleitung.
Spezikationen
Befestigung: An einem Shelly Plus Gerät befestigt
Abmessungen (HxBxT): 37x42x15 mm
Arbeitstemperatur: -20°C bis 40°C
Max. Höhe ü.M.: 2000m
Spannungsversorgung: 2.3 VDC (über Shelly Plus Gerät)
Stromverbrauch: < 0,5 W (ohne Sensoren)
Analoger Eingangsbereich: 0 - 10 VDC
Schwellenwert r die Meldung des Analogeingangs:
0,1 VDC*
Abtastrate des Analogeingangs: 1 Hz
Analoge Messgenauigkeit: besser als 5%
Digitale Eingangspegel: -15 V bis 0,5 V (Wahr) / 2,5 V
bis 15 V (Falsch)**
Schraubklemmen max. Drehmoment: 0,1 Nm
Leitungsquerschnitt: max. 1 mm²
Länge des Drahtes: 4,5 mm
*Kann in den Einstellungen des Analogeingangs konguriert
werden
**Logik kann in den digitalen Eingangseinstellungen inver-
tiert werden
Konformitätserklärung
Hiermit erklärt Allterco Robotics EOOD, dass der Funk-
anlagentyp Shelly Plus Add-on der Richtlinie 2014/53/EU,
2014/35/EU, 2014/30/EU, 2011/65/EU entspricht. Den
vollsndigen Text der EU-Konformitätserklärung nden
Sie unter folgender Internetadresse
www.shelly.cloud/knowledge-base/devices/shelly-plus-add-on/
Hersteller: Allterco Robotics EOOD
Adresse: 103 Cherni vrah Blvd., 1407 Soa, Bulgarien
Tel.: +359 2 988 7435
E-Mail: support@shelly.cloud
Internet: https://www.shelly.cloud
Änderungen der Kontaktdaten werden vom Hersteller auf
dessen oziellen Website veröffentlicht
https://www.shelly.cloud
Alle Rechte an der Marke Shelly® und anderen geistigen
Eigentumsrechten im Zusammenhang mit diesem Gerät
gehören Allterco Robotics EOOD.
DHT22 come mostrato in Fig. 1 A o no a 5 sensori di
temperatura digitali DS18B20 come mostrato in Fig. 1 B.
ATTENZIONE! Non collegare più di un sensore DHT22 o
una combinazione di sensori DHT22 e DS18B20.
Collegare un potenziometro da 10 kΩ come mostrato in
Fig. 2 A per letture analogiche uniformi o un termistore con
resistenza nominale di 10 e β=4000 K come mostrato
in Fig. 2 B per la misurazione analogica della temperatura.
È inoltre possibile misurare la tensione di una sorgente
esterna nell‘intervallo da 0 a 10 VDC. La resistenza interna
della sorgente di tensione dovrebbe essere inferiore a 10
kΩ per prestazioni ottimali.
Il dispositivo fornisce anche un‘interfaccia a un segnale
digitale ausiliario attraverso il suo ingresso digitale. Col-
legare un interruttore/pulsante, un relè o un dispositivo
elettronico come mostrato in Fig. 2.
Se il dispositivo Shelly Plus, a cui è collegato Shelly Plus
Addon, non è stato collegato alla rete elettrica, installarlo
seguendo la guida per l‘utente e la sicurezza.
Speciche tecniche
Montaggio: Collegato a un dispositivo Shelly Plus
Dimensioni (AxLxP): 37x42x15 mm
Temperatura di lavoro: -20°C to 40°C
Altitudine massima: 2000 m
Alimentazione:
Consumo elettrico: < 0,5 W (senza sensori)
Intervallo di ingresso analogico: 0 - 10 VDC
Soglia rapporto ingresso analogico: 0,1 VDC*
Frequenza di campionamento dell‘ingresso analogico:
1 Hz
Precisione della misurazione analogica: migliore del 5%
Livelli di ingresso digitale: da -15 V a 0,5 V (vero) /
da 2,5 V a 15 V (falso)**
Morsetti a vite max. coppia: 0,1 Nm
Sezione del lo: max. 1 mm²
Lunghezza della striscia di lo: 4,5 mm
* Può essere congurato nelle impostazioni dell‘ingresso
analogico
** La logica può essere invertita nelle impostazioni dell‘in-
gresso digitale
Dichiarazione di conformi
Con la presente, Allterco Robotics EOOD dichiara che il
tipo di apparecchiatura radio Shelly Plus Add-on è con-
forme alla Direttiva 2014/53/UE, 2014/35/UE, 2014/30/
UE, 2011/65/UE. Il testo completo della dichiarazione di
conformità UE è disponibile al seguente indirizzo internet
www.shelly.cloud/knowledge-base/devices/shelly-plus-add-on/
Produttore: Allterco Robotics EOOD
Indirizzo: Bulgaria, Soa, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Web: https://www.shelly.cloud
Le modiche ai dati di contatto sono pubblicate dal Produt-
tore sul sito Web uciale del Dispositivo
https://www.shelly.cloud
Tutti i diritti sul marchio Shelly® e altri diritti intellettuali
associati a questo dispositivo appartengono a Allterco
Robotics EOOD.
DATA
VCC
GND
2 DATA
1 VCC
4 GND
3 NC
DATA
VCC
GND
DATA
VCC
GND
DHT22
VREF
DIGI LTA
VREF + R1
ANALOG
GND
GND
VREF OUT
DIGI L INTA
VREF +R1 OUT
ANALOG IN
GND
GND
-t°
AC
D
B
A
B
SCHEMATIC / SCHEMATISCHE DARSTELLUNG / SCHEMA
DATA
VCC
GND
DATA
VCC
GND
DATA
VCC
GND
2 DATA
3 VDD
1 GND
DS18B20
2 DATA
3 VDD
1 GND
DS18B20
2 DATA
3 VDD
1 GND
DS18B20
2 DATA
3 VDD
1 GND
DS18B20
2 DATA
3 VDD
1 GND
DS18B20
g.1A g.1B g.2A g.2B g.3
42/2022


Produkt Specifikationer

Mærke: Shelly
Kategori: Smart hjem
Model: Plus

Har du brug for hjælp?

Hvis du har brug for hjælp til Shelly Plus stil et spørgsmål nedenfor, og andre brugere vil svare dig




Smart hjem Shelly Manualer

Shelly

Shelly Wave Shutter Manual

3 September 2024
Shelly

Shelly Wave i4 Manual

3 September 2024
Shelly

Shelly Wave Pro 2 Manual

3 September 2024
Shelly

Shelly Plus Un Manual

3 September 2024
Shelly

Shelly Pro Dimmer 1PM Manual

3 September 2024
Shelly

Shelly Wave Pro 1PM Manual

3 September 2024
Shelly

Shelly Wave Pro 2PM Manual

3 September 2024
Shelly

Shelly Pro Dimmer 2PM Manual

3 September 2024
Shelly

Shelly Wave Pro 1 Manual

3 September 2024

Smart hjem Manualer

Nyeste Smart hjem Manualer

Vimar

Vimar 20461.N Manual

15 December 2024
Vimar

Vimar 19537.M Manual

15 December 2024
Vimar

Vimar 14461.SL Manual

15 December 2024
Vimar

Vimar 14537 Manual

15 December 2024
Vimar

Vimar R21511.1.B Manual

15 December 2024
Vimar

Vimar R21511.1 Manual

15 December 2024
Vimar

Vimar 16849.B Manual

15 December 2024
Vimar

Vimar 19849 Manual

15 December 2024
Vimar

Vimar 20172.120.N Manual

15 December 2024