Cresnet® Partition Sensor
Installation and Operation Guide
Description
The Crestron® GLS-PART-CN is a partition sensor that is controlled by the Cresnet
®
network and designed for installation into a 1-gang electrical box or surface mounting. The
GLS-PART-CN has a contact closure output (EXT) that allows for use in a non-system
environment.
Installation
NOTE: Observe the following points:
Install and use this product in accordance with appropriate electrical codes and
regulations.
If you are unsure about any part of these instructions, consult a qualied electrician.
Sensors must be mounted on a vibration-free surface.
NOTE: Before using the GLS-PART-CN, ensure the device is using the latest rmware.
Check for the latest rmware for the GLS-PART-CN at www.crestron.com/rmware.
Load the rmware onto the device using Crestron Toolbox™ software.
Preparing and Connecting Wires
When making connections, strip the ends of the wires approximately 7/16 in (11 mm). Use
care to avoid nicking the conductors. Tighten the connector to 5 in-lb (0.5 to 0.6 Nm). The
wire gauge should be 14 to 26 AWG.
Wiring the GLS-PART-CN
The 5-pin terminal block connects the GLS-PART-CN to the Cresnet network (24 Y Z G)
and to a non-system device (EXT).
Wire the GLS-PART-CN
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest rmware updates. Use a QR
reader application on your mobile device to scan the QR image.
Standard 1-gang
electrical box
Ceiling
Mounting
screws (2)
Faceplate
(Not included)
3. Attach the desired decorator style faceplate (not supplied).
GLS-PART-CN Installed in a 1-Gang Electrical Box with Faceplate
4. Turn the Cresnet system power on.
Surface Mount the GLS-PART-CN
After the Cresnet network wiring has been installed and veried, use the following
procedure to surface mount the GLS-PART-CN.
1. Remove the two screws from the back of the GLS-PART-CN and then remove the
bracket. Retain the screws.
Remove these two screws in order to swap the mounting
brackets. Reuse the screws for reassembly using the
other mounting bracket.
Connection to the
control system Contact closure output for
non-system environment
Ceiling Mount in 1-Gang Electrical Box
After the Cresnet network wiring has been installed and veried, use the following
procedure to install the device in a standard 1-gang electrical box.
1. Holding the GLS-PART-CN with the sensors facing the area to be monitored, place
the GLS-PART-CN into the electrical box.
2. Secure the GLS-PART-CN using the included screws.
Installing the GLS-PART-CN in a 1-Gang Electrical Box
Mounting Location
Position the GLS-PART-CN 2 ft (0.6 m) away from the partition. The GLS-PART-CN
sensors must face the partition so that when the partition opens, the sensor sees the
unobstructed room.
Sensor Mounting Location (Bottom View)
2 ft (0.6 m)
Partition


Produkt Specifikationer

Mærke: Crestron
Kategori: Smart hjem
Model: GLS-PART-CN

Har du brug for hjælp?

Hvis du har brug for hjælp til Crestron GLS-PART-CN stil et spørgsmål nedenfor, og andre brugere vil svare dig




Smart hjem Crestron Manualer

Smart hjem Manualer

Nyeste Smart hjem Manualer

Vimar

Vimar 20461.N Manual

15 December 2024
Vimar

Vimar 19537.M Manual

15 December 2024
Vimar

Vimar 14461.SL Manual

15 December 2024
Vimar

Vimar 14537 Manual

15 December 2024
Vimar

Vimar R21511.1.B Manual

15 December 2024
Vimar

Vimar R21511.1 Manual

15 December 2024
Vimar

Vimar 16849.B Manual

15 December 2024
Vimar

Vimar 19849 Manual

15 December 2024
Vimar

Vimar 20172.120.N Manual

15 December 2024